Permit Application Status

PRRES20162554


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162554
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY DECK FINISHED BASEMENT
10/05/2016
10/25/2016
09/20/2018
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
PARK HOMES LLC, Address:4550 WARWICK BLVD APT 1204, Phone:(816) 564-2333  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
4SIGHT GROUP LLC, Address:7920 WARD PKWY, Phone:(816) 802-8400  
MCGRATH ELECTRIC, Address:601 E MAIN ST, Phone:(816) 726-3265  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/07/2016 10/06/2016
James Fletchall
Plot Plan Review (P&D) Approved 10/07/2016 10/06/2016
Hector Soto Jr.
Residential Plan Review Approved 10/07/2016 10/05/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $764.48 $764.48 Paid 10/25/2016
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/25/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/25/2016
Water Meter Fee $405.36 $405.36 Paid 10/25/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/25/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 10/27/2016 (8:15) 10/27/2016 10/27/2016
Misc
Corrective Action Required
10/27/2016
PROVIDE PLAN ON SITE
Footing Inspection - Residential Passed 10/28/2016 10/28/2016 10/28/2016
Misc
Resolved
10/28/2016
PROVIDE PLAN ON SITE
Underslab Plumbing Inspection - Residential Passed 11/17/2016 11/17/2016 11/17/2016
Electrical Service Inspection Failed 2/2/2017 02/02/2017
Misc
Corrective Action Required
02/02/2017
-LOCATE AND GROUND TO UFER
Gas Service Inspection - Residential Failed 2/2/2017 2/2/2017 02/02/2017
Misc
Corrective Action Required
02/02/2017
-NO PRESSURE
All Rough Inspection - Residential Failed 2/2/2017 2/2/2017 at 2:43 PM 02/02/2017
Misc
Corrective Action Required
02/02/2017
FRAMING: -STOOP SUSPENDED SLAB WAS NOT INSPECTED. SEND ENGINEER LETTER APPROVING THE FLOOR -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUDS, SILL PLATE, AND HEADER PER PLAN; MORE NAILING FOR EAST H-FRAME -ATTIC ACCESS -EXTERIOR DOORS-SECURITY BLOCKING AT STRIKE PLATE HEIGHT -NAIL CORNER STUDS W/ 16D@12" OC OR EQUIVALENT NAILING -INSTALL VAPOR BARRIER IN MASTER SHOWER -STRAP WALL TOP PLATES AT MASTER BED CORNER -WALL AT MASTER CLOSET/BATH NOT BEARING WALL -FIREBLOCKING: FB ALL FLOOR HOLES AND PENETRATIONS THROUGHOUT; FB FIREPLACE SPACE WITH 3/4" SHEATHING; FB FIREPLACE SPACE FROM ROOF SPACE; FB BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE; FB BASEEMNT WALL AT TOP AND EVERY TEN FT AND FB GAP ABOVE AND BELOW. SHALL USE 3/4" SHEATHING OR OTHER APPROVED MATERIAL; SEAL ALL RETURN AIR SPACE PENETRATIONS ELECTRICAL: -PROTECT WIRING THROUGHOUT (NEAR OVEN, MASTER BED, ETC) -MAKE SURE KITCHEN COUNTER RECEPTACLE SPACING IS PER CODE.AT ANY POINT ALONG THE COUNTERTOP WALL, THERE SHALL BE A RECEPTCLE WITHIN 24" -INSTALL BUSHING TO PROTECT WIRING ENTRY INTO THE FIREPLACE BOX -COMPLETE WIRING MAKE-UP FOR ALL BOXES MECHANICAL: -PAN OFF AND SEAL RETURN AIR SPACE FROM THE FIREPLACE SPACE -PROTECT AC COOLANT LINE ABOVE BASEMENT BATH DOOR -VENT MASTER BATH FAN PLUMBING: -PROTECT PLUMBING THROUGHOUT (LAUNDRY/LIVING RM WALL, GARAGE LAUNDRY WALL, FRONT BATH, BASEMENT BATH, ETC). NAIL ALL TOP PLATE STRAP NAIL HOLES -ROOF FLASHING FOR VENTS -PROTECT GAS CSST AT ENTRY INTO FIREPLACE BOX; SECURE CSST PER CODE -COMPLETE PLUMBING IN MASTER SHOWER AND PROTECT AS REQUIRED ***OK TO INSULATE ***FYI: ONE OF THE CAT CABLE IS CUT OUTSIDE BASEMENT BED
Electrical Service Inspection Failed 2/9/2017 02/09/2017
Misc
Corrective Action Required
02/02/2017
-LOCATE AND GROUND TO UFER
All Rough Inspection - Residential Failed 2/9/2017 2/9/2017 02/09/2017
Misc
Corrective Action Required
02/02/2017
****INSTALL EROSION CONTROL PER REQUIREMENT. NO FURTHER INSPECTION IF EC IS NOT IN COMPLIANCE FRAMING: -STOOP SUSPENDED SLAB WAS NOT INSPECTED. SEND ENGINEER LETTER APPROVING THE FLOOR -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUDS, SILL PLATE, AND HEADER PER PLAN; **ANY SEAM OF THE SHEATHING MUST LOCATE WITHIN 24" OF THE MID-WALL HEIGHT **NAIL SHEATHING TO HEADER AND SILL PLATE -FIREBLOCKING: FB FIREPLACE SPACE FROM ROOF SPACE **REMOVE THE PAPER FACING AND STAPLE THE FIBERGLASS TO FRAMING ELECTRICAL: -SINCE THE ELECTRICIAN NEEDS TO COME BACK TO GROUND THE SERVICE TO UFER, HE CAN REPLACE THE OVER-FILLED SINGLE GANG BOX AT MASTER CLOSET DOOR MECHANICAL: -VENT MASTER BATH FAN ***DO NOT ROCK
Gas Service Inspection - Residential Passed 2/9/2017 02/09/2017
Misc
Resolved
02/09/2017
-NO PRESSURE
Sewer Service Inspection - R Failed 2/14/2017 (1:15) 2/14/2017 02/14/2017
Misc
Corrective Action Required
02/14/2017
-EXPOSE THE TRACER WIRE CONNECTION. USE SPLIT BOLT TO CONNECT THE TRACER WIRES -REPAIR DAMAGED DRAIN TILE
Sewer Service Inspection - R Passed 2/15/2017 02/15/2017
Misc
Resolved
02/15/2017
-EXPOSE THE TRACER WIRE CONNECTION. USE SPLIT BOLT TO CONNECT THE TRACER WIRES -REPAIR DAMAGED DRAIN TILE
All Rough Inspection - Residential Failed 2/16/2017 2/16/2017 02/16/2017
Misc
Corrective Action Required
02/09/2017
****INSTALL EROSION CONTROL PER REQUIREMENT. NO FURTHER INSPECTION IF EC IS NOT IN COMPLIANCE -FIREBLOCK FIREPLACE SPACE FROM ROOF SPACE **STAPLE THE FIBERGLASS TO FRAMING ***DO NOT ROCK
Electrical Service Inspection Failed 2/16/2017 2/16/2017 02/16/2017
Misc
Corrective Action Required
02/09/2017
-INSTALL A LISTED REBAR GROUNDING CLAMP. THE ACORN CLAMP IS LISTED ONLY FOR GROUNDING TO GROUNDING ROD, WHICH CAN BE IN CONTACT WITH THE COPPER GROUNDING ELECTRODE CONDUCTOR.
Water Service Inspection - R Partial 2/17/2017 (8:00) 2/17/2017 02/17/2017
All Rough Inspection - Residential Passed 2/17/2017 02/17/2017
Misc
Resolved
02/17/2017
****INSTALL EROSION CONTROL PER REQUIREMENT. NO FURTHER INSPECTION IF EC IS NOT IN COMPLIANCE -FIREBLOCK FIREPLACE SPACE FROM ROOF SPACE **STAPLE THE FIBERGLASS TO FRAMING ***DO NOT ROCK
Electrical Service Inspection Passed 2/17/2017 02/17/2017
Misc
Resolved
02/17/2017
-INSTALL A LISTED REBAR GROUNDING CLAMP. THE ACORN CLAMP IS LISTED ONLY FOR GROUNDING TO GROUNDING ROD, WHICH CAN BE IN CONTACT WITH THE COPPER GROUNDING ELECTRODE CONDUCTOR.
Water Service Inspection - R Passed 2/17/2017 (2:00) 2/17/2017 02/17/2017
Driveway Inspection Passed 3/23/2017 3/23/2017 03/23/2017
Piers/Caissons Inspection - Residential Failed 5/16/2017 5/16/2017 05/16/2017
Misc
Corrective Action Required
05/16/2017
16" DIA PIER ALL THE WAY TO BOTTOM
Piers/Caissons Inspection - Residential Passed 5/16/2017 (2:30) 5/16/2017 05/16/2017
Misc
Resolved
05/16/2017
16" DIA PIER ALL THE WAY TO BOTTOM
Occupancy Inspection - Codes Residential Failed 6/27/2017 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/27/2017
-OBTAIN LAWN SPRINKLER PERMIT -EXPOSE WATER METER. MAKE SURE THE DISTANCE FROM TOP OF METER TO LID IS 14"-18" -EXPOSE THE SEWER TRACER WIRE ACCESS BOX -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR: LIGHTS AD ALL PENETRATIONS -CLOSE EXTERIOR WALL OPENING OUTSIDE MASTER BED -MOVE THE AC DISCONNECT TO LOCATION THAT ALLOWS PROPER WORKING CLEARANCE -RECEPTACLE AT LAUNDRY SINK NOT GFCI -THE CEILING LUMINAIRES IN MASTER CLOSET SHALL BE ENCLOSED-LAMP TYPE. OPEN CAN LIGHT NOT ALLOWED -GARAGE IS NOT ACCESSIBLE AT THIS TIME -INSTALL FACE PLATES THROUGHOUT -BOND SWITCHES THROUGHOUT -COMPLETE INSTALLATION OF FLOOR RECEPTACLES. INSTALL BOX EXTENSIONS FOR FLOOR RECEPTACLE BOXES NOT FLUSHED WITH CARPET -COMPLETE GAS CONNECTION TO COOKTOP -INSTALL WATER HAMMERING ARRESTOR FOR DISH WASHER AND CLOTHES WASHER -DECK RECEPTACLE IS NOT GFCI -INSTALL BREAKER LOCKS FOR OVEN AND WATER HEATER -INSTALL SWITCH WITHIN SIGHT FOR THE BASEMENT BATHFAN -PROVIDE COMBUSTION AIR OPENINGS FOR MECH SPACE PER CODE -INSTALL SEWER CLEAN OUT PLUG -STOOP SUSPENDED SLAB WAS NOT INSPECTED -SECURE FURNACE AND WATER HEATER LFNC RACEWAY PER CODE -REMOVE ALL FOUNDATION WALL TIES -INSTALL ADDITIONAL RECEPTACLE (GFCI) IN MECH SPACE(IN ADDITION TO THE DEDICATED RECEPTACLE) -PROVIDE ACCESS TO UFER GROUNDING CONNECTION -EXTERIOR DOOR: INSTALL SECURITY STRIKE PLATE WITH 4-3" SCREWS; INSTALL 2-3" SCREWS FOR EACH HINGE
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2017 6/29/2017 06/29/2017
Misc
Corrective Action Required
06/28/2017
-OBTAIN LAWN SPRINKLER PERMIT -EXPOSE WATER METER. MAKE SURE THE DISTANCE FROM TOP OF METER TO LID IS 14"-18" -EXPOSE THE SEWER TRACER WIRE ACCESS BOX -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR: LIGHTS AND ALL PENETRATIONS -CLOSE EXTERIOR WALL OPENING OUTSIDE MASTER BED -MOVE THE AC DISCONNECT TO LOCATION THAT ALLOWS PROPER WORKING CLEARANCE -ONE GARAGE RECEPTACLE NOT GFCI OR DEDICATED -COMPLETE INSTALLATION OF FLOOR RECEPTACLES. **PROPERLY SUPPORT BOXES -DECK RECEPTACLE IS NOT GFCI **INSTALL SPARK RING AND COVER -INSTALL SWITCH WITHIN SIGHT FOR THE BASEMENT BATHFAN **LOCATE THE CIRCUIT BREAKER FOR THE BATHFAN AND INSTALL A BREAKER LOCK **LABEL BASEMENT BED RECEPTACLE CIRCUIT BREAKER
Occupancy Inspection - Codes Residential Temporary C of O 7/5/2018 7/5/2018 at 8:35 AM 07/05/2018
Misc
Corrective Action Required
06/29/2017
-EXPOSE THE SEWER TRACER WIRE ACCESS BOX -MOVE THE AC DISCONNECT TO LOCATION THAT ALLOWS PROPER WORKING CLEARANCE
Occupancy Inspection - Codes Residential Full C of O 9/20/2018 at 9:55 AM 09/20/2018
Misc
Resolved
09/20/2018
-EXPOSE THE SEWER TRACER WIRE ACCESS BOX -MOVE THE AC DISCONNECT TO LOCATION THAT ALLOWS PROPER WORKING CLEARANCE
Documents & Images
Date Uploaded File Type Document Name
10/25/2016 Receipt Receipt for transaction: 2016-006551
10/25/2016 Letter Codes Building Permit
10/25/2016 Plot Plan DOC102516-001
10/27/2016 Letter Inspection Summary
10/28/2016 Letter Inspection Summary
11/17/2016 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
02/09/2017 Letter Inspection Summary
02/14/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
03/23/2017 Letter Inspection Summary
05/16/2017 Letter Inspection Summary
05/16/2017 Letter Inspection Summary
06/28/2017 Letter Inspection Summary
06/29/2017 Letter Codes Temporary Certificate of Occupancy
08/01/2017 Letter Codes 10 Day Letter
08/16/2017 Engineer Report/Study DOC081617-003
07/05/2018 Letter Codes Temporary Certificate of Occupancy
09/20/2018 Letter Field Certificate of Occupancy
09/21/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home