Permit Application Status

PRRES20161966


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20161966
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK' FINISHED BASEMENT
08/04/2016
08/08/2016
09/07/2018
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/08/2016 08/05/2016
James Fletchall
Plot Plan Review (P&D) Approved 08/08/2016 08/04/2016
Christina Stanton
Residential Plan Review Approved 08/08/2016 08/04/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $826.50 $826.50 Paid 08/08/2016
8331507-Sewer Connection Fee $420.00 $420.00 Paid 08/08/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 08/08/2016
Water Meter Fee $405.36 $405.36 Paid 08/08/2016
Right of Way Permit Fee $75.00 $75.00 Paid 08/08/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/28/2016 9/28/2016 09/28/2016
Piers/Caissons Inspection - Residential Passed 9/28/2016 09/28/2016
Underslab Plumbing Inspection - Residential Passed 10/12/2016 10/12/2016 10/12/2016
Water Service Inspection - R Passed 10/18/2016 (9:00) 10/18/2016 10/18/2016
Sewer Service Inspection - R Passed 10/18/2016 (11:15) 10/18/2016 10/18/2016
All Rough Inspection - Residential Failed 1/19/2017 1/19/2017 01/19/2017
Misc
Corrective Action Required
01/19/2017
-STRAP GARAGE PORTAL -PROVIDE ACCESS TO 3RD CAR ATTIC -INSTALL ANCHOR BOLTS GARAGE WHERE REQUIRED -INSTALL BLOCKS AT SPLICES IN SHEATHING GARAGE PND HOOK UORTAL AND NAIL. -NAIL EXTERIOR SHEATHING AS REQUIRED FOR BRACED WALLS. -FIREBLOCK BASEMENT THROUGHOUT PER CODE -BLOCK FLOOR JOISTS PER LAYOUT -RE LOCATE BASEMENT BATH FAN TO CEILING LEVEL AND HOOK UP EXAUST. -PROTECT PLUMBING STACK NORTH END AT BASE -HANGER TWO DOUBLE TJI JOISTS -INSTALL SECURITY BLOCKING BOTH REAR DOORS. -DECK 6x6 POSTS, PLANS CALL FOR CONTINUOUS POST, HAVE ENGINEER ADDRESS. -BOTH DOUBLE END JOSITS ON DECK HAVE NO BEARING OR HANGER. -ANCHOR COLUMN IN BASEMENT.
Gas Service Inspection - Residential Passed 1/19/2017 1/19/2017 01/19/2017
Gas Piping Inspection - Residential Passed 01/19/2017
Electrical Service Inspection Passed 1/19/2017 1/19/2017 01/19/2017
All Rough Inspection - Residential Failed 1/27/2017 1/27/2017 01/27/2017
Misc
Corrective Action Required
01/19/2017
-FIREBLOCK BASEMENT THROUGHOUT PER CODE -BLOCK FLOOR JOISTS PER LAYOUT -INSTALL SECURITY BLOCKING BOTH REAR DOORS. -DECK 6x6 POSTS, PLANS CALL FOR CONTINUOUS POST, HAVE ENGINEER ADDRESS. -BOTH DOUBLE END JOSITS ON DECK HAVE NO BEARING OR HANGER.
All Rough Inspection - Residential Failed 1/31/2017 1/31/2017 01/31/2017
Misc
Corrective Action Required
01/27/2017
-FIREBLOCK BASEMENT THROUGHOUT PER CODE **FB ALL WALL SPACE FROM CEILING FURDOWN SPACE. ALL THE GAPS IN THE FIREBLOCKING SHEATHING MUST BE CLOSED WITH APPROVED FIREBLOCKING MATERIAL -BLOCK FLOOR JOISTS PER LAYOUT **OK HOW ARE YOU GOING TO INSULATE THE FLOOR NOW? INSULATE BEFORE BLOCKING -INSTALL SECURITY BLOCKING BOTH REAR DOORS. **BLOCK THE STUD 3 STUD SPACES OUT (OR TO CORNER OR WINDOW) -DECK 6x6 POSTS, PLANS CALL FOR CONTINUOUS POST, HAVE ENGINEER ADDRESS.
All Rough Inspection - Residential Passed 2/3/2017 2/3/2017 02/03/2017
Misc
Resolved
02/03/2017
-FIREBLOCK BASEMENT THROUGHOUT PER CODE **FB ALL WALL SPACE FROM CEILING FURDOWN SPACE. ALL THE GAPS IN THE FIREBLOCKING SHEATHING MUST BE CLOSED WITH APPROVED FIREBLOCKING MATERIAL -BLOCK FLOOR JOISTS PER LAYOUT **OK HOW ARE YOU GOING TO INSULATE THE FLOOR NOW? INSULATE BEFORE BLOCKING -INSTALL SECURITY BLOCKING BOTH REAR DOORS. **BLOCK THE STUD 3 STUD SPACES OUT (OR TO CORNER OR WINDOW) -DECK 6x6 POSTS, PLANS CALL FOR CONTINUOUS POST, HAVE ENGINEER ADDRESS.
Driveway Inspection Partial 2/27/2017 02/27/2017
Driveway Inspection Passed 3/6/2017 03/06/2017
PW-Misc
Informational
03/06/2017
Tom Chandler 03/06/2017 3:20 PM Driveway is complete and passed final inspection.
Sidewalk Inspection Partial 4/24/2017 4/24/2017 04/24/2017
Informational
04/24/2017
Tom Chandler 04/24/2017 4:16 PM Inspected forms only.
Sidewalk Inspection Passed 4/28/2017 04/27/2017
Informational
04/27/2017
Tom Chandler 04/27/2017 9:55 AM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Failed 5/3/2017 5/3/2017 05/03/2017
Misc
Corrective Action Required
05/03/2017
-INSTALL FINAL GRADE, SOD, SPLASHBLOCKS -CHECK NAMEPLATE RATING OF AC AT LATER INSPECTION, 50 AMP BREAKER INSTALLED. -PART OF THE DECK IS ATTACHED TO A CANTILEVERED PORTION OF THE HOUSE. -INSTALL SECURITY SCREWS REAR DOOR. -FIRE PROTECT FLOORS IN UNFINISHED AREAS
Occupancy Inspection - Codes Residential Failed 5/16/2017 5/16/2017 05/16/2017
Misc
Resolved
05/16/2017
REQUIRED FOR TCofO: -PART OF THE DECK IS ATTACHED TO A CANTILEVERED PORTION OF THE HOUSE. Update: Attempted resolution is not adequate. Recommend alteration at direction of an Engineer. REQUIRED FOR FULL CofO: -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS
Occupancy Inspection - Codes Residential Temporary C of O 05/16/2017
Misc
Resolved
05/16/2017
REQUIRED FOR TCofO: -PART OF THE DECK IS ATTACHED TO A CANTILEVERED PORTION OF THE HOUSE. Update-1: Attempted resolution is not adequate. Recommend alteration at direction of an Engineer. Update-2: Letter from Bradley Huxol, PE recieved; indicates deck attachment to cantelevered portion of framing is structurally sound. No further action needed. REQUIRED FOR FULL CofO: -INSTALL FINAL GRADE, SOD, SPLASHBLOCKS
Occupancy Inspection - Codes Residential Temporary C of O 7/19/2017 07/19/2017
Misc
Corrective Action Required
07/19/2017
Final grade not correct at rear of property. Slope should be continuous from the rear of the house to the rear of the property. Currently, a ridge is present that will trap water on the patio.
Occupancy Inspection - Codes Residential Full C of O 9/7/2018 09/07/2018
Misc
Resolved
09/07/2018
Final grade not correct at rear of property. Slope should be continuous from the rear of the house to the rear of the property. Currently, a ridge is present that will trap water on the patio.
Documents & Images
Date Uploaded File Type Document Name
08/08/2016 Receipt Receipt for transaction: 2016-005310
08/08/2016 Letter Codes Building Permit
08/08/2016 Plot Plan DOC080816-015
09/12/2016 REVISED PLOT PLAN
09/28/2016 Letter Inspection Summary
10/12/2016 Letter Inspection Summary
10/18/2016 Letter Inspection Summary
10/18/2016 Letter Inspection Summary
01/19/2017 Letter Inspection Summary
01/27/2017 Letter Inspection Summary
01/31/2017 Letter Inspection Summary
02/03/2017 Letter Inspection Summary
03/06/2017 Letter PW-Daily Inspection Summary
04/27/2017 Letter PW-Daily Inspection Summary
05/03/2017 Letter Inspection Summary
05/16/2017 Letter Inspection Summary
05/16/2017 Engineer Report/Study 95 Millcreek deck connection
05/16/2017 Letter Inspection Summary
05/16/2017 Letter Codes Temporary Certificate of Occupancy
05/16/2017 Engineer Report/Study 95 Millcreek deck connection
07/19/2017 Letter Codes Temporary Certificate of Occupancy
09/07/2018 Letter Field Certificate of Occupancy
09/10/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home