Permit Application Status

PRRES20160787


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20160787
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY WITH DECK AND UNFINISHED BASEMENT
04/11/2016
04/18/2016
12/16/2016
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/18/2016 04/14/2016
James Fletchall
Plot Plan Review Rejected 04/13/2016 04/14/2016
James Fletchall
Plot Plan Review (P&D) Approved 04/13/2016 04/11/2016
Christina Stanton
Residential Plan Review Approved 04/13/2016 04/11/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $990.13 $990.13 Paid 04/18/2016
Right of Way Permit Fee $75.00 $75.00 Paid 04/18/2016
8331507-Sewer Connection Fee $540.00 $540.00 Paid 04/18/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 04/18/2016
Water Meter Fee $377.18 $377.18 Paid 04/18/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/28/2016 (11:30) 4/28/2016 04/28/2016
Underslab Plumbing Inspection - Residential Not Ready 5/9/2016 5/10/2016 05/10/2016
Misc
Corrective Action Required
05/10/2016
DENIED FOR DEFICIANT EROSION CONTROL
Sewer Service Inspection - R Passed 5/13/2016 (8:00) 5/13/2016 05/13/2016
Water Service Inspection - R Passed 5/13/2016 (9:30) 5/13/2016 05/13/2016
Underslab Plumbing Inspection - Residential Passed 05/13/2016
Misc
Corrective Action Required
05/10/2016
DENIED FOR DEFICIANT EROSION CONTROL
Suspended Slab Inspection Passed 6/14/2016 (10:00) 6/14/2016 06/14/2016
Driveway Inspection Partial 6/30/2016 06/30/2016
Driveway Inspection Passed 7/7/2016 07/07/2016
PW-Misc
Informational
07/07/2016
Tom Chandler 07/07/2016 2:43 PM Driveway complete and passed inspection.
Suspended Slab Inspection Passed 7/18/2016 (11:30) 7/18/2016 07/18/2016
Gas Service Inspection - Residential Passed 7/29/2016 7/29/2016 07/29/2016
Electrical Service Inspection Passed 7/29/2016 7/29/2016 07/29/2016
All Rough Inspection - Residential Failed 7/29/2016 7/29/2016 07/29/2016
Misc
Corrective Action Required
07/29/2016
FRAMING: -NAIL GARAGE PORTAL BRACE WALLS SHEATHING PER CODE. SEE PLAN -FIREBLOCKING: FB DUCT CHASE FROM JOIST SPACE; FB WALL&DUCT CHASE AT PANTRY FROM CEILING SPACE; FB ALL LOW-VOLTAGE WIRING FLOOR&CEILING PENETRATIONS;FB DUCT CHASE FROM ROOF SPACE -NAIL ALL CORNER STUDS WITH 16D @ 12" OC OR EQUIVALENT NAILING -HAVE ENGINEER ADDRESS THE FOLLOWING: GREATROOM REAR NARROW BRACE WALLS NOT FRAMED PER PLAN; DOUBLE LVL BEAM ABOVE KITCHEN NOT EXTENDING TO BEARING WALL; -NAIL STUDS AT ALL WALL INTERSECTIONS THROUGHOUT HOUSE -FILL IN GAP AT DECK DOOR HINGES WITH SOLID WOOD -COMPLETE FUR OUT FOR GARAGE I BEAM -STRAP TOP PLATES LAPPED LESS THAN 24" AT 2ND FL REAR CLOSET -BRACE ALL INTERIOR WALLS PER PLAN -TIE DOWN GIRDERS AT FRONT BED; TRUSS AT MASTER BED/BATH SHOWER CORNER; -INSTALL SOLID SUPPORT BELOW POINT LOAD OF THE 7-STUDS GARAGE I BEAM SUPPORT -INSTALL SOLID SUPPORT BELOW THE I BEAM POINT LOADS AT REAR GREATROOM WALL -INSTALL HANGERS ABOVE FURNACE AND ABOVE WATER HEATERS -ANCHOR BASEMENT SILL PLATE WITHIN 12" OF BREAKS; MIN. 2 ANCHORS PER PLATE (SEE SHORT PLATE) MECHANICAL: -PROVIDE MIN. 1" CLEARANCE AROUND B-VENT 2ND FL CHASE PLUMBING: -STRAP ACROSS TOP PLATES AT ALL PVC PENETRATIONS WHERE THE TOP PLATES ARE BORED MORE THAN 50% AT EXTERIOR WALL AND INTERIOR BEARING WALLS. -VENT CONNECTION FOR TUB TRAP SHALL BE WITHIN 6 FT OF TRAP WEIR (ABOVE GREATROOM). -PROTECT PVC BELOW KITCHEN SINK ELECTRICAL: -INSTALL A REAR RECEPTACLE ACCESSIBLE FROM GRADE AND WITHIN 6.5 FT OF GRADE -INSTALL A RECEPTACLE WITHIN 25 FT OF AC UNIT -PROTECT WIRING AT WALL BOTTOM PLATE 4 FT LEFT OF REFRIGERATOR; SECURE HOME RUNS MIN. 1.25" AWAY FROM NAILING SURFACE AT 1/2 BATH **OK TO INSULATE
All Rough Inspection - Residential Failed 8/15/2016 8/15/2016 08/15/2016
Misc
Resolved
08/15/2016
FRAMING: -NAIL GARAGE PORTAL BRACE WALLS SHEATHING PER CODE. SEE PLAN -FIREBLOCKING: FB DUCT CHASE FROM JOIST SPACE; FB WALL&DUCT CHASE AT PANTRY FROM CEILING SPACE; FB ALL LOW-VOLTAGE WIRING FLOOR&CEILING PENETRATIONS;FB DUCT CHASE FROM ROOF SPACE -NAIL ALL CORNER STUDS WITH 16D @ 12" OC OR EQUIVALENT NAILING -HAVE ENGINEER ADDRESS THE FOLLOWING: GREATROOM REAR NARROW BRACE WALLS NOT FRAMED PER PLAN; DOUBLE LVL BEAM ABOVE KITCHEN NOT EXTENDING TO BEARING WALL; -NAIL STUDS AT ALL WALL INTERSECTIONS THROUGHOUT HOUSE -FILL IN GAP AT DECK DOOR HINGES WITH SOLID WOOD -COMPLETE FUR OUT FOR GARAGE I BEAM -STRAP TOP PLATES LAPPED LESS THAN 24" AT 2ND FL REAR CLOSET -BRACE ALL INTERIOR WALLS PER PLAN -TIE DOWN GIRDERS AT FRONT BED; TRUSS AT MASTER BED/BATH SHOWER CORNER; -INSTALL SOLID SUPPORT BELOW POINT LOAD OF THE 7-STUDS GARAGE I BEAM SUPPORT -INSTALL SOLID SUPPORT BELOW THE I BEAM POINT LOADS AT REAR GREATROOM WALL -INSTALL HANGERS ABOVE FURNACE AND ABOVE WATER HEATERS -ANCHOR BASEMENT SILL PLATE WITHIN 12" OF BREAKS; MIN. 2 ANCHORS PER PLATE (SEE SHORT PLATE) MECHANICAL: -PROVIDE MIN. 1" CLEARANCE AROUND B-VENT 2ND FL CHASE PLUMBING: -STRAP ACROSS TOP PLATES AT ALL PVC PENETRATIONS WHERE THE TOP PLATES ARE BORED MORE THAN 50% AT EXTERIOR WALL AND INTERIOR BEARING WALLS. -VENT CONNECTION FOR TUB TRAP SHALL BE WITHIN 6 FT OF TRAP WEIR (ABOVE GREATROOM). -PROTECT PVC BELOW KITCHEN SINK ELECTRICAL: -INSTALL A REAR RECEPTACLE ACCESSIBLE FROM GRADE AND WITHIN 6.5 FT OF GRADE -INSTALL A RECEPTACLE WITHIN 25 FT OF AC UNIT -PROTECT WIRING AT WALL BOTTOM PLATE 4 FT LEFT OF REFRIGERATOR; SECURE HOME RUNS MIN. 1.25" AWAY FROM NAILING SURFACE AT 1/2 BATH **OK TO INSULATE
Misc
Corrective Action Required
08/15/2016
ENGINEER REPORT DID NOT ADDRESS REAR BRACED WALL FRAMING AND THE FRAMING IS STILL NOT FRAMED IN ACCORDANCE WITH THE PLAN.
All Rough Inspection - Residential Passed 8/17/2016 8/17/2016 08/17/2016
Misc
Resolved
08/17/2016
ENGINEER REPORT DID NOT ADDRESS REAR BRACED WALL FRAMING AND THE FRAMING IS STILL NOT FRAMED IN ACCORDANCE WITH THE PLAN.
Occupancy Inspection - Codes Residential Failed 10/27/2016 10/27/2016 10/27/2016
Misc
Corrective Action Required
10/27/2016
-DECK PIERS NOT APPROVED ON RECORD -FINAL GRADE, SOD, SPLASHBLOCKS -GRADE UP AT OPEN SIDE OF TEH FRONT STOOP FLOOR SO THAT THE VERTICAL DISTANCE FROM STOOP TO GRADE, MEASURED AT 36" OUT FROM EDGE, IS LESS THAN 30", OR INSTALL GUARDRAIL -RELOCATE THE AC DISCONNECT TO LOCATION THAT ALLOWS ACCESSIBLE SPACE PER CODE -INSTALL GARAGE DOOR TRACK-SUPPORT BRACKET PER DESIGN (3RD FROM FLOOR @ 58". HAVE THE DESIGN DOCUMENT ON SITE) -RELOCATE THE RECEPTACLE TO HAVE DIRECT VIEW FROM HYDROTUB MOTOR ACCESS OPENING -INSTALL ANTI-BACKFLOW DEVICE FOR BASEMENT HOSE BIBB -PROTECT TJI FLOOR JOISTS PER IRC 501.3 -FIREBLOCK THE BASEMENT FROM GARAGE CHASE
Occupancy Inspection - Codes Residential Temporary C of O 10/28/2016 10/28/2016 10/28/2016
Misc
Corrective Action Required
10/27/2016
-FINAL GRADE, SOD, SPLASHBLOCKS
Occupancy Inspection - Codes Residential Full C of O 12/16/2016 12/16/2016 12/16/2016
Misc
Resolved
12/16/2016
-FINAL GRADE, SOD, SPLASHBLOCKS
Documents & Images
Date Uploaded File Type Document Name
04/18/2016 Receipt Receipt for transaction: 2016-001189
04/18/2016 Letter Codes Building Permit
04/18/2016 Plot Plan DOC041816-008
04/28/2016 Letter Inspection Summary
05/10/2016 Letter Inspection Summary
05/13/2016 Letter Inspection Summary
06/14/2016 Letter Inspection Summary
07/07/2016 Letter PW-Daily Inspection Summary
07/18/2016 Letter Inspection Summary
07/29/2016 Letter Inspection Summary
08/11/2016 Engineer Report/Study DOC081116-012
08/15/2016 Letter Inspection Summary
08/17/2016 Letter Inspection Summary
10/27/2016 Letter Inspection Summary
10/28/2016 Letter Codes Temporary Certificate of Occupancy
12/16/2016 Letter Field Certificate of Occupancy
12/19/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home