Summary
PRCOM20251162
Building Permit - Commercial
Issued
NEW MULTI-FAMILY
THE REUNION AT BLACKWELL - BUILDING 24, TYPE B1 4-PLEX PLAN REVIEW COMPLETED UNDER PRCOM20250089
03/31/2025
06/17/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit A, Phone:(816) 249-2270  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/14/2025 03/31/2025
Mike Weisenborn
Building Plan Review Approved with Conditions 04/14/2025 03/31/2025
Mike Weisenborn
Miscellaneous Correction
Resolved
06/17/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Licensed Contractors Approved 04/14/2025 03/31/2025
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $10,595.00 $10,595.00 Paid 04/03/2025
Water Meter Fee $1,066.76 $1,066.76 Paid 04/03/2025
Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 04/03/2025
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 04/03/2025
Valuation Fee for New 3 or 4 Family $3,998.93 $3,998.93 Paid 04/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/24/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 04/01/2026
Outstanding Fees Amount Paid Owing Date Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Erosion Control Inspection Pending
Misc
Corrective Action Required
07/01/2025
No further inspections until erosion control in compliance -clean storm drain top and inlet -clean curb and street -repair downed silt fence
Sidewalk Inspection Pending
Misc
Corrective Action Required
02/12/2026
2-5-26 Dustin A, sw in back of property along sw highland Park dr has been formed and compacted. Approved to pour 2-12-26 Dustin A, To much silt on sw to do final inspection. Ada ramp is cracked . Will need to call in for final sw inspection when sidewalk is cleaned off
Occupancy Inspection - Engineering Pending
Misc
Corrective Action Required
03/26/2026
3-26-26 Dustin A, Punch List for Final 1. Water valve near vault needs to be cut to grade and correct top hat installed 2. ADA ramp is cracked and needs to be replaced
Occupancy Inspection - Codes Commercial Pending
Misc
Corrective Action Required
04/01/2026
Address pending sidewalk inspection All units -splash blocks to extend 36” from foundation -provide clearance from grade for siding - pay outstanding not ready fee
Footing Inspection - Commercial Partial 6/10/2025 6/10/2025 06/10/2025
Misc
Informational
06/10/2025
Footings okay.
Footing Inspection - Commercial Partial 6/16/2025 6/16/2025 06/16/2025
Misc
Informational
06/10/2025
-Footings okay. -stem wall okay
Underslab Plumbing Inspection - Commercial Failed 7/1/2025 7/1/2025 07/01/2025
Misc
Corrective Action Required
07/01/2025
Inspection denied pump water out for inspection Address erosion control issues before calling for reinspection
Erosion Control Inspection Failed 7/1/2025 7/1/2025 07/01/2025
Misc
Corrective Action Required
07/01/2025
No further inspections until erosion control in compliance -clean storm drain top and inlet -clean curb and street -repair downed silt fence
Underslab Plumbing Inspection - Commercial Not Ready 7/2/2025 7/2/2025 07/02/2025
Misc
Corrective Action Required
07/01/2025
Not ready for inspection Uncover all covered pipe for inspection Address erosion control issues before calling for reinspection
Underslab Plumbing Inspection - Commercial Passed 7/3/2025 7/3/2025 07/03/2025
Misc
Resolved
07/03/2025
Not ready for inspection Uncover all covered pipe for inspection Address erosion control issues before calling for reinspection
Underslab Electrical Inspection - Commercial Passed 07/03/2025
Footing Inspection - Commercial Passed 7/9/2025 7/9/2025 07/09/2025
Misc
Informational
06/16/2025
-Footings okay. -stem wall okay -thickened slab areas OK
Sewer Service Inspection Passed 7/22/2025 7/22/2025 07/22/2025
Miscellaneous Correction
Informational
07/22/2025
07/22/25, Jamie S, Sewer Service has fall, correct bedding, and is connected to tracer wire.
Water Service Inspection Passed 08/25/2025
Misc
Informational
08/25/2025
8-20-25 Dustin A, Water service is in and pit is installed to city specs
Rated Assembly Inspection Failed 8/28/2025 8/28/2025 08/28/2025
Misc
Corrective Action Required
08/28/2025
Inspection denied no address posted
Rated Assembly Inspection Failed 8/29/2025 8/29/2025 08/29/2025
Misc
Corrective Action Required
08/28/2025
Exterior sheathing inspection only. No plans on site to confirm portal framing locations or sheathing nail pattern requirements Nail all truss ends to sheathing where missing
Rated Assembly Inspection Failed 9/4/2025 9/4/2025 09/04/2025
Misc
Corrective Action Required
08/29/2025
Exterior sheathing nailing, including garage PFH walls-OK
Rated Assembly Inspection Not Ready 10/7/2025 10/7/2025 10/07/2025
Misc
Corrective Action Required
09/04/2025
Exterior sheathing nailing, including garage PFH walls-OK
Misc
Corrective Action Required
10/07/2025
Not ready for inspection, nothing done
Electrical Service Inspection Failed 10/7/2025 10/7/2025 10/07/2025
Misc
Corrective Action Required
10/07/2025
Electrical not done not ready for inspection
All Rough Inspection - Commercial Failed 11/10/2025 11/10/2025 11/10/2025
Misc
Corrective Action Required
11/10/2025
-Missing address -erosion control not in compliance
All Rough Inspection - Commercial Failed 11/13/2025 11/13/2025 11/13/2025
Misc
Resolved
11/13/2025
-Missing address -erosion control not in compliance
Misc
Corrective Action Required
11/13/2025
Trusses not fully inspected check all hangers, holddowns, nailing and bracing Throughout -seal 10’ horizontal fire blocking gaps and where using sheerock will not come to face of framing -protect all wiring within 6’ of attic accesses -nail all trusses doubled to plans -nail all stud packs together -nail all intersecting wall corners to code 636 -stud spacing greater than 16” OC rear bedroom -seal top plate penetration garage S wall and replace notched stud -address supply vent at furnace not connected -secure furnace whip -secure SE Cable in attic space -support bath vents in attic space 638 -seal top plate penetrations rear garage wall -broken truss above 4 trusses in from rear bedroom -seal top plate penetrations at vanity wall 636/638 -vent bath vents to exterior -dryer vent not complete -address beam added to double truss above great room(not supported, not on plans, why is this added?) -nail double truss together 640 -seal gap in fireblock for separation walls -separation wall horizontal fire blocking greater to 10’ 640/642 - 642 -land electrical in garage -tighten anchor bolt in back bedroom
All Rough Inspection - Commercial Failed 11/17/2025 11/17/2025 11/17/2025
Misc
Corrective Action Required
11/13/2025
Throughout Seal gaps in 10’ fire blocking in separation wall throughout -secure electrical in attic space 636 -stud spacing greater than 16” OC rear bedroom (stud used to fix issue over notched ) 638 -broken truss 4 trusses in from rear bedroom great room -address beam added to double truss above great room(not supported, not on plans, why is this added?) 640 -seal gap in 10’ fireblock for separation wall -address 4 broken trusses above unit 642 -land electrical in garage -tighten anchor bolt in back bedroom
Driveway Inspection Failed 11/24/2025 11/24/2025 11/24/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted.
All Rough Inspection - Commercial Failed 12/3/2025 12/3/2025 12/03/2025
Misc
Corrective Action Required
11/17/2025
Throughout Secure all cables in attic every 4.5’ per code 636 Holes being drilled in top plate near electrical service exterior wall(work still being done) 638 -address beam added to double truss above great room(not supported/ no bearing. Not fixed to engineer specifications, screws are through plates and both sides) 640 -repair truss to engineer specifications outside entry bath 642
Driveway Inspection Partial 12/8/2025 12/8/2025 12/08/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, DW is compacted and there is no standing water . Approved to pour , Reminder ground temps need to be above 32 and rising. Dw under commercial permits need to 8 in .
All Rough Inspection - Commercial Not Ready 12/10/2025 12/10/2025 12/10/2025
Misc
Corrective Action Required
12/03/2025
Throughout 636 Fireblock Holes being drilled in top plate near electrical service exterior wall 638 -address beam added to double truss above great room(not supported/ no bearing. Not fixed to engineer specifications, screws are through plates and both sides) 640 642
Rated Assembly Inspection Failed 12/10/2025 12/10/2025 12/10/2025
Misc
Corrective Action Required
10/07/2025
Exterior sheathing nailing, including garage PFH walls-OK
Misc
Corrective Action Required
10/07/2025
Not ready for inspection, missing nails throughout
Rated Assembly Inspection Failed 12/11/2025 12/11/2025 12/11/2025
Misc
Corrective Action Required
12/10/2025
Exterior sheathing nailing, including garage PFH walls-OK
Misc
Corrective Action Required
12/10/2025
640 -truss up rights missing sheet rock Entire wall must be covered
All Rough Inspection - Commercial Not Ready 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/10/2025
Throughout 636 638 -address beam added to double truss above great room(not supported/ no bearing. Not fixed to engineer specifications, screws are through plates and both sides) 640 642
Rated Assembly Inspection Partial 12/15/2025 12/15/2025 12/15/2025
Misc
Informational
12/15/2025
Exterior sheathing nailing, including garage PFH walls-OK 1st layer sheet rock screw pattern-okay
Misc
Resolved
12/15/2025
640 -truss up rights missing sheet rock Entire wall
Electrical Service Inspection Failed 12/15/2025 12/15/2025 12/15/2025
Misc
Resolved
12/15/2025
Electrical not done not ready for inspection
Misc
Corrective Action Required
12/15/2025
-no more than one conductor per lug in panel -copper main bonding jumper shall be minimum #4
Driveway Inspection Partial 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/08/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, DW is compacted and there is no standing water . Approved to pour , Reminder ground temps need to be above 32 and rising. Dw under commercial permits need to 8 in .
Electrical Service Inspection Passed 12/18/2025 12/18/2025 12/18/2025
Misc
Resolved
12/18/2025
-no more than one conductor per lug in panel -copper main bonding jumper shall be minimum #4
All Rough Inspection - Commercial Not Ready 12/18/2025 12/18/2025 12/18/2025
Misc
Corrective Action Required
12/15/2025
Throughout 636 638 -address beam added to double truss above great room(not supported/ no bearing. Not fixed to engineer specifications, screws are through plates and both sides) READ engineer letter, fix is not to engineer specifications, you haw screwed through all metal connector plates. Have engineer address this 640 642
Driveway Inspection Passed 12/22/2025 12/22/2025 12/22/2025
Misc
Corrective Action Required
12/15/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, DW is compacted and there is no standing water . Approved to pour , Reminder ground temps need to be above 32 and rising. Dw under commercial permits need to 8 in . 12-22-25 Dustin A, dw poured to city spec
Rated Assembly Inspection Partial 12/29/2025 12/29/2025 12/29/2025
Misc
Informational
12/15/2025
Exterior sheathing nailing, including garage PFH walls-OK 1st layer sheet rock screw pattern-okay 2nd layer in attic space okay to tape
Rated Assembly Inspection Partial 1/5/2026 1/5/2026 01/05/2026
Misc
Informational
12/29/2025
Exterior sheathing nailing, including garage PFH walls-OK 1st layer sheet rock screw pattern-okay 2nd layer in attic space okay to tape Ceiling space complete
All Rough Inspection - Commercial Partial 1/6/2026 1/6/2026 01/06/2026
Misc
Resolved
01/06/2026
Throughout 636 638 -address beam added to double truss above great room(not supported/ no bearing. Not fixed to engineer specifications, screws are through plates and both sides) READ engineer letter, fix is not to engineer specifications, you haw screwed through all metal connector plates. Have engineer address this 640 642
Misc
Corrective Action Required
01/06/2026
Will check GB bracing at time of drywall
Rated Assembly Inspection Partial 1/13/2026 1/13/2026 01/13/2026
Misc
Informational
01/05/2026
Following areas inspected Exterior sheathing nailing, including garage PFH walls-OK 1st layer sheet rock screw pattern-okay 2nd layer in attic space okay to tape Ceiling space complete GB BRACING
Sidewalk Inspection Partial 2/5/2026 2/5/2026 02/05/2026
Misc
Corrective Action Required
02/05/2026
2-5-26 Dustin A, sw in back of property along sw highland Park dr has been formed and compacted. Approved to pour
Sidewalk Inspection Partial 2/12/2026 2/12/2026 02/12/2026
Misc
Corrective Action Required
02/05/2026
2-5-26 Dustin A, sw in back of property along sw highland Park dr has been formed and compacted. Approved to pour 2-12-26 Dustin A, To much silt on sw to do final inspection. Ada ramp is cracked . Will need to call in for final sw inspection when sidewalk is cleaned off
All Rough Inspection - Commercial Passed 03/26/2026
Misc
Resolved
03/26/2026
Will check GB bracing at time of drywall
Rated Assembly Inspection Passed 03/26/2026
Misc
Informational
01/13/2026
Following areas inspected Exterior sheathing nailing, including garage PFH walls-OK 1st layer sheet rock screw pattern-okay 2nd layer in attic space okay to tape Ceiling space complete GB BRACING
Occupancy Inspection - Codes Commercial Failed 3/26/2026 3/26/2026 03/26/2026
Misc
Corrective Action Required
03/26/2026
Address pending sidewalk inspection All units -sod -splash blocks to extend 36” from foundation -provide clearance from grade for siding -correctly identified each units meter and disconnect (2 unit numbers are listed for each meter and disconnect) 636 - 638 -entry circuit to be afci protected 640 -entry circuit to be Afci protected 642
Occupancy Inspection - Engineering Temporary C of O 3/26/2026 3/26/2026 03/26/2026
Misc
Corrective Action Required
03/26/2026
3-26-26 Dustin A, Punch List for Final 1. Water valve near vault needs to be cut to grade and correct top hat installed 2. ADA ramp is cracked and needs to be replaced
Occupancy Inspection - Codes Commercial Not Ready 3/31/2026 3/31/2026 03/31/2026
Misc
Corrective Action Required
03/26/2026
Address pending sidewalk inspection All units -splash blocks to extend 36” from foundation -provide clearance from grade for siding -correctly identified each units meter and disconnect (2 unit numbers are listed for each meter and disconnect) 636 - 638 -entry circuit to be afci protected (not done) 640 -entry circuit to be Afci protected (not done) 642
Occupancy Inspection - Codes Commercial Ready for Temp CO 4/1/2026 4/1/2026 04/01/2026
Misc
Corrective Action Required
03/31/2026
Address pending sidewalk inspection All units -splash blocks to extend 36” from foundation -provide clearance from grade for siding - pay outstanding not ready fee
Documents & Images
Date Uploaded File Type Document Name
04/03/2025 Receipt Receipt for transaction:2025-002032
04/03/2025 Letter DS Building Permit
03/31/2025 Approved Plans Approved plans V1
06/10/2025 Letter INSPECTION SUMMARY
06/16/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter DS Building Permit
07/01/2025 Letter INSPECTION SUMMARY
07/01/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/03/2025 Letter INSPECTION SUMMARY
07/03/2025 Letter INSPECTION SUMMARY
07/09/2025 Letter INSPECTION SUMMARY
03/31/2025 Approved Plans Approved plans V1
03/06/2025 Approved Plans Approved plans V2
07/22/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
08/28/2025 Letter INSPECTION SUMMARY
08/29/2025 Letter INSPECTION SUMMARY
08/29/2025 Letter INSPECTION SUMMARY
09/04/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
11/05/2025 Approved Plans Approved G111
11/06/2025 Approved Plans Approved trusses B1
11/10/2025 Letter INSPECTION SUMMARY
11/12/2025 Approved Plans Approved Truss repair
11/13/2025 Letter INSPECTION SUMMARY
11/17/2025 Letter INSPECTION SUMMARY
11/17/2025 Approved Plans Truss repair doc
11/24/2025 Letter INSPECTION SUMMARY
12/03/2025 Approved Plans Approved truss repair
12/03/2025 Letter INSPECTION SUMMARY
12/08/2025 Approved Plans Approved E200 revision
12/08/2025 Letter INSPECTION SUMMARY
12/08/2025 Letter INSPECTION SUMMARY
12/10/2025 Letter INSPECTION SUMMARY
12/10/2025 Letter INSPECTION SUMMARY
12/11/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/18/2025 Letter INSPECTION SUMMARY
12/18/2025 Letter INSPECTION SUMMARY
12/22/2025 Letter INSPECTION SUMMARY
12/29/2025 Letter INSPECTION SUMMARY
01/05/2026 Approved Plans Approved - Roof truss fix PRCOM20251162
01/05/2026 Letter INSPECTION SUMMARY
01/06/2026 Letter INSPECTION SUMMARY
01/13/2026 Letter INSPECTION SUMMARY
02/05/2026 Letter INSPECTION SUMMARY
02/09/2026 Approved Plans REUNION GRADING PLA
02/12/2026 Letter INSPECTION SUMMARY
03/24/2026 Receipt Receipt for transaction:2026-001774
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/26/2026 Letter INSPECTION SUMMARY
03/31/2026 Letter INSPECTION SUMMARY
04/01/2026 Receipt Receipt for transaction:2026-001928
04/01/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home