Summary
PRCOM20232358
Building Permit - Commercial
Certificate of Occupancy
NLV TOWNHOMES LLC
NEW MULTI-FAMILY
VILLAGE AT NEW LONGVIEW TOWNHOMES PHASE 1 - BUILDING 4-5 UNIT TOWNHOMES
05/24/2023
07/27/2023
07/17/2023
11/18/2024
Locations
Contacts
NLV TOWNHOMES LLC, Address:3152 SW GRANDSTAND CIR  
O'REILLY BUILD LLC, Address:5051 S NATIONAL AVE STE 4-110, Phone:(417) 862-9500  
Jacob Johnson - O'Reilly Build, Phone:(318) 413-2151  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CLAYCO ELECTRIC COMPANY, Address:319 E 11TH AVE, Phone:(816) 221-0593  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
CLOCKWORK, Address:423 DELAWARE STREET #102, Phone:(816) 807-3787  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/20/2023 05/08/2023
Joe Frogge
LC - General Contractor
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential Excise Tax Fee $2,121.60 $2,121.60 Paid 07/18/2023
9110078-Valuation Fee for New Multi-Family $8,919.79 $8,919.79 Paid 07/18/2023
8331401-Water Tap Fee $18,800.00 $18,800.00 Paid 07/18/2023
8350015-Water Meter Fee $3,402.30 $3,402.30 Paid 07/18/2023
8331507-Sanitary Sewer Development Fee $10,795.00 $10,795.00 Paid 07/18/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/31/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 9/29/2023 09/29/2023
Misc
Corrective Action Required
09/29/2023
Building 4 - North and West side.
Footing Inspection - Commercial Passed 10/3/2023 10/3/2023 10/03/2023
Misc
Informational
10/03/2023
Building 4
Foundation Inspection - Commercial Passed 10/19/2023 (8:30) 10/19/2023 10/19/2023
Misc
Informational
10/19/2023
Building 4 approved
Underslab Plumbing Inspection - Commercial Passed 10/24/2024 11/06/2023
Underslab Electrical Inspection - Commercial Passed 11/6/2023 11/06/2023
Foundation Inspection - Commercial Passed 11/14/2023 (2:00) 11/14/2023 11/14/2023
Misc
Informational
11/14/2023
Inspection of steel of basement floor
Footing Inspection - Commercial Partial 2/26/2024 02/26/2024
Misc
Corrective Action Required
02/26/2024
BUILDING 4 - 450 ONLY, REBAR FOR STOOP OK
Footing Inspection - Commercial Passed 2/27/2024 2/27/2024 02/27/2024
Misc
Informational
02/27/2024
BUILDING 4 - 450 ,452, 454, 456, 458, ONLY, REBAR FOR STOOP OK
Foundation Inspection - Commercial Partial 3/5/2024 3/5/2024 03/05/2024
Misc
Corrective Action Required
03/05/2024
Steel for stoops at building 4 450 & 456,458
Foundation Inspection - Commercial Passed 3/13/2024 3/13/2024 03/13/2024
Misc
Resolved
03/13/2024
Steel for stoops at building 4 ALL UNITS
Electrical Service Inspection Passed 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/17/2024
- BUILDING 4
All Rough Inspection - Commercial Failed 5/1/2024 5/1/2024 05/01/2024
Misc
Corrective Action Required
05/01/2024
Fb= Fire block 450 Main floor •Fb floor penetration at A/C chase •Provide front door Second floor •Fb gaps at top of chase front bedroom/ shower •Vent at laundry to be round not distorted •Fb demise wall top plate rock wool missing in some areas •Provide stud shoe bathroom back wall •Fb floor penetration at a/c duct chase Basement •provide Egress window •Fb vertically every 10’ of demise wall •Fb top plate of demise wall with rock wool where missing •Submit plan for protection of plumbing in demise wall at floor 452 Main floor •provide missing door •Fb top of HVAC chase Second floor •Fb gaps top at chase master bathroom/ shower and HVAC •Fb HVAC at stairs chase at floor •Laundry vent to be round Basement •provide Egress window •Fb top plate of demise wall •Fb vertically every 10’ of demise wall •Submit plans to address plumbing from floor into demise wall 454 Main floor •provide missing door •Fb top of HVAC chase and floor penetration Second floor •fb penetration at floor of HVAC chase near stairs also provide missing stud •Laundry vent to be round •Fb top plate of demise wall walls gap back bedroom Basement •provide Egress window •Fb demise wall vertically every 10’ •Fb top plate gap of demise wall 456 Main floor •Provide missing door •Fb penetrations at top plate bathroom vanity wall Second floor •laundry vent to be round •Fb HVAC chase across from stairs, seal gaps and use approved materials •Provide stud shoes for over board of Bering wall. Back wall •Provide missing windows Basement •provide space for sheet rock at stairs •Provide Egress window •Water line in demise wall 458 Main floor •provide missing door Second floor •Fb HVAC chase at back of house seal gaps •Laundry vent to be round •Provide missing windows •Fb gaps at shower chase top plate Basement •address plumbing in demise wall •Provide Egress window
Sprinkler - Hydrostatic Test Passed 05/01/2024
All Rough Inspection - Commercial Failed 5/13/2024 5/13/2024 05/13/2024
Misc
Corrective Action Required
05/01/2024
OK to insulate Do not sheet rock until missing stud shoes are inspected. 450 Main floor •Provide front door Second floor •Provide stud shoe bathroom back wall Basement •provide Egress window •Submit plan for protection of plumbing in demise wall at floor 452 Main floor •provide missing door Second floor •Laundry vent to be round Basement •provide Egress window •Submit plans to address plumbing from floor into demise wall 454 Main floor •provide missing door Second floor •Laundry vent to be round Basement •provide Egress window 456 Main floor •Provide missing door Second floor •laundry vent to be round •Provide stud shoes for over board of Bering wall. Back wall •Provide missing windows Basement •Provide Egress window •Water line in demise wall 458 Main floor •provide missing door Second floor •Laundry vent to be round •Provide missing windows Basement •address plumbing in demise wall •Provide Egress window
Rated Assembly Inspection Partial 5/29/2024 5/29/2024 05/29/2024
Misc
Corrective Action Required
05/29/2024
Rated Assembly 450- OK to cover 452- Address plumbing in basement demise wall ( leave open) Ok to cover 454- Address plumbing in basement demise wall ( leave open) Ok to cover 456, 458 - not inspected
Erosion Control Inspection Residential Failed 5/29/2024 05/29/2024
Misc
Corrective Action Required
05/29/2024
- REPAIR SILT FENCE AROUND SOUTH EAST CORNER OF LOT.
Footing Inspection - Commercial Partial 6/6/2024 6/6/2024 06/06/2024
Misc
Informational
06/06/2024
- Footing for Building 4 garages approved
Erosion Control Inspection Residential Failed 6/11/2024 06/11/2024
Misc
Corrective Action Required
06/11/2024
- TRIM TALL VEGETATION ON LOT.
Rated Assembly Inspection Partial 6/11/2024 6/11/2024 06/11/2024
Misc
Corrective Action Required
05/29/2024
Rated Assembly 450- OK to cover 452- Address plumbing in basement demise wall ( leave open) Ok to cover 454- Address plumbing in basement demise wall ( leave open) Ok to cover 456 OK 458 OK
Foundation Inspection - Commercial Partial 6/12/2024 (11:00) 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
BUILDING 4 110 FOOT NORTH WALL & EAST WALL 2 PIER PADS 456,458
Erosion Control Inspection Residential Failed 6/12/2024 06/12/2024
Corrective Action Required
06/12/2024
- TRIM TALL VEGETATION ON LOT.
Footing Inspection - Commercial Passed 8/26/2024 08/26/2024
Misc
Informational
06/06/2024
- Footing for Building 4 garages approved
Foundation Inspection - Commercial Passed 8/26/2024 08/26/2024
Misc
Informational
06/12/2024
BUILDING 4 110 FOOT NORTH WALL & EAST WALL 2 PIER PADS 456,458
All Rough Inspection - Commercial Partial 8/26/2024 08/26/2024
Misc
Corrective Action Required
08/26/2024
Gargages Building 4 - Provide attic access -Nail patern for shear walls approved
Underground Electrical Inspection - Commercial Partial 8/27/2024 8/27/2024 08/27/2024
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
08/27/2024
- Inspection of conduit for monument sign located at South West corner of property ran East to South East corner of building 4 - inspection of light pole base South East corner of building 4 - Conduit ran in front of building 4 to quasi box between building 3–4
All Rough Inspection - Commercial Partial 8/30/2024 08/30/2024
Misc
Corrective Action Required
05/13/2024
OK to insulate Do not sheet rock until missing stud shoes are inspected. 450 Main floor •Provide front door Second floor •Provide stud shoe bathroom back wall Basement •provide Egress window •Submit plan for protection of plumbing in demise wall at floor 452 Main floor •provide missing door Second floor •Laundry vent to be round Basement •provide Egress window •Submit plans to address plumbing from floor into demise wall 454 Main floor •provide missing door Second floor •Laundry vent to be round Basement •provide Egress window 456 Main floor •Provide missing door Second floor •laundry vent to be round •Provide stud shoes for over board of Bering wall. Back wall •Provide missing windows Basement •Provide Egress window •Water line in demise wall 458 Main floor •provide missing door Second floor •Laundry vent to be round •Provide missing windows Basement •address plumbing in demise wall •Provide Egress window
Misc
Corrective Action Required
08/30/2024
450 sw Brumel GARGES 450-458 - provide 2x2” washers at portal frame anchorage on all - Draft stop all top plate penetrations all units - Provide engineering on broken truss in 458
Misc
Informational
08/30/2024
450 sw Brumel All deck framing approved All breezeway covers framing with fire rock 1 side. Approved
All Rough Inspection - Commercial Passed 9/4/2024 09/04/2024
Misc
Resolved
09/04/2024
Gargages Only Building 4 : Approved
Erosion Control Inspection Residential Failed 9/13/2024 09/13/2024
Misc
Corrective Action Required
09/13/2024
- TRIM VEGETATION ON LOT
Rated Assembly Inspection Passed 9/13/2024 09/13/2024
Misc
Resolved
09/13/2024
Underground Electrical Inspection - Commercial Passed 09/13/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/13/2024
- Inspection of conduit for monument sign located at South West corner of property ran East to South East corner of building 4 - inspection of light pole base South East corner of building 4 - Conduit ran in front of building 4 to quasi box between building 3–4
Gas Piping Inspection - Commercial Passed 10/10/2024 10/10/2024
Gas Service Inspection - Commercial Passed 10/10/2024 10/10/2024
Miscellaneous Inspection Failed 10/10/2024 10/10/2024 10/10/2024
Misc
Corrective Action Required
10/10/2024
450 S W BRUMMEL Pre check All units - complete handrails and guards at front porch - Water meter pits at grade - Complete lights at porch - Seal exterior penetrations - Provide gutters and downspouts - Splash pads - Complete all courtyards - All garages to have 1 outlet per car bay - Support expansion tanks at water heaters - Pressure regulator required at each units water service after fire sprinkler line - Provide blanks at all open slots in all electrical sub panels 450 - address sprinkler head at second floor attic access - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 452 - Close attic access lid lifted by screws - Secure water main line to code - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 454 - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 456 - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 458 - Install a anti siphon device to spigot at water main in basement - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected
Occupancy Inspection - Planning Passed 10/24/2024 10/24/2024
Occupancy Inspection - Engineering Failed 10/24/2024 10/24/2024
Miscellaneous Correction
Corrective Action Required
10/24/2024
10-24-24 DP. Building 4 punch list: -Need to fix list for water meter issues -Fix broken curb, especially in front of ADA ramp -Extend indicator pad at ADA the width of the opening.
Occupancy Inspection - Codes Commercial Failed 10/24/2024 10/24/2024
Misc
Corrective Action Required
10/24/2024
450 S W BRUMMEL All units - complete handrails and guards at front porch - Water meter pits at grade - Provide gutters and downspouts - Splash pads - Pressure regulator required at each units water service after fire sprinkler line 450ok 452 - Missing 2 blanks for knock outs at electrical panel 454 - Missing 2 blanks for knock outs at electrical panel 456 - Missing 2 blanks for knock outs in electrical panel 458 - Install a anti siphon device to spigot at water main in basement
Erosion Control Inspection Residential Passed 10/24/2024 10/24/2024
Misc
Resolved
10/24/2024
- TRIM TALL VEGETATION ON LOT.
Miscellaneous Inspection Passed 10/24/2024 10/24/2024
Misc
Resolved
10/24/2024
450 S W BRUMMEL Pre check All units - complete handrails and guards at front porch - Water meter pits at grade - Complete lights at porch - Seal exterior penetrations - Provide gutters and downspouts - Splash pads - Complete all courtyards - All garages to have 1 outlet per car bay - Support expansion tanks at water heaters - Pressure regulator required at each units water service after fire sprinkler line - Provide blanks at all open slots in all electrical sub panels 450 - address sprinkler head at second floor attic access - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 452 - Close attic access lid lifted by screws - Secure water main line to code - Label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 454 - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 456 - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected 458 - Install a anti siphon device to spigot at water main in basement - label non GFCI outlet at water heater - Outlet at electrical panel to be GFCI protected
Occupancy Inspection - Codes Commercial Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/24/2024
All units - Provide Splash pads - All water mains to have regulator installed after fire sprinkler line
Occupancy Inspection - Codes Commercial Failed 10/30/2024 10/30/2024 10/30/2024
Misc
Corrective Action Required
10/29/2024
All units - Provide Splash pads - All water mains to have regulator installed after fire sprinkler line Shawn Hoffman 10/30/2024 1:37 PM incorrect instalation of regulators
Occupancy Inspection - Engineering Temporary C of O 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Corrective Action Required
10/24/2024
10-24-24 DP. Building 4 punch list: -Need to fix list for water meter issues -Fix broken curb, especially in front of ADA ramp -Extend indicator pad at ADA the width of the opening. 10-30-24 DP. Water meters issues have been repaired. TCO Granted. Still need to fix site related work before receiving C/O
Water Service Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP. All water service inspections have been installed and repairs have been completed.
Sewer Service Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP All sewer services have been installed and repairs have been completed.
Occupancy Inspection - Engineering Passed 10/31/2024 10/31/2024 10/31/2024
Miscellaneous Correction
Corrective Action Required
10/30/2024
10-24-24 DP. Building 4 punch list: -Need to fix list for water meter issues -Fix broken curb, especially in front of ADA ramp -Extend indicator pad at ADA the width of the opening. 10-30-24 DP. Water meters issues have been repaired. TCO Granted. Still need to fix site related work before receiving C/O 10-31-24 DP. All punch list items have been completed for building 4. Any site related issues will transfer to PRSITE20224130
Occupancy Inspection - Engineering Passed 10/31/2024
Miscellaneous Correction
Corrective Action Required
10/24/2024
10-24-24 DP. Building 4 punch list: -Need to fix list for water meter issues -Fix broken curb, especially in front of ADA ramp -Extend indicator pad at ADA the width of the opening. 10-31-24 DP. Punch list items for building 4 are complete. Sitework related items were transferred to PRSITE.
Occupancy Inspection - Codes Commercial Ready for Temp CO 10/31/2024 10/31/2024
Misc
Corrective Action Required
10/30/2024
All units - Provide Splash pads
Occupancy Inspection - Codes Commercial Full C of O 11/18/2024 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
All units - Provide Splash pads
Documents & Images
Date Uploaded File Type Document Name
07/18/2023 Receipt Receipt for transaction:2023-005574
07/27/2023 Letter DS Building Permit
09/29/2023 Letter INSPECTION SUMMARY
10/19/2023 Letter INSPECTION SUMMARY
10/19/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/31/2024 Receipt Receipt for transaction:2024-008701
11/18/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.