Summary
PRCOM20232356
Building Permit - Commercial
Certificate of Occupancy
NLV TOWNHOMES LLC
NEW MULTI-FAMILY
VILLAGE AT NEW LONGVIEW TOWNHOMES PHASE 1 - BUILDING 2- 7 UNIT TOWNHOMES
05/24/2023
05/26/2023
07/17/2023
11/18/2024
Locations
Contacts
NLV TOWNHOMES LLC, Address:3152 SW GRANDSTAND CIR  
O'REILLY BUILD LLC, Address:5051 S NATIONAL AVE STE 4-110, Phone:(417) 862-9500  
Jacob Johnson - O'Reilly Build, Phone:(318) 413-2151  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CLAYCO ELECTRIC COMPANY, Address:319 E 11TH AVE, Phone:(816) 221-0593  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
CLOCKWORK, Address:423 DELAWARE STREET #102, Phone:(816) 807-3787  
NLV TOWNHOMES LLC, Address:3152 SW GRANDSTAND CIR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/20/2023 05/08/2023
Joe Frogge
LC - General Contractor
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Resolved
05/08/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential Excise Tax Fee $2,970.24 $2,970.24 Paid 05/26/2023
9110078-Valuation Fee for New Multi-Family $12,487.71 $12,487.71 Paid 05/26/2023
8331401-Water Tap Fee $26,110.00 $26,110.00 Paid 06/19/2023
8350015-Water Meter Fee $3,853.50 $3,853.50 Paid 06/19/2023
8331507-Sanitary Sewer Development Fee $9,688.00 $9,688.00 Paid 06/19/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/12/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/12/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 6/29/2023 (1:00) 6/30/2023 06/30/2023
Misc
Informational
06/30/2023
- BA B1-B9, B1 BA-BC, B9 BA-BC OK
Footing Inspection - Commercial Passed 7/7/2023 (10:30) 7/7/2023 07/07/2023
Misc
Informational
06/30/2023
- BA B1-B9, B1 BA-BC, B9 BA-BC OK - BC B1-B9 B2 BA- BC, B8 BA-BC OK
Footing Inspection - Commercial Passed 7/12/2023 (2:00) 7/12/2023 07/12/2023
Misc
Informational
07/12/2023
Building 2 complete
Foundation Inspection - Commercial Passed 7/25/2023 (11:00) 7/26/2023 07/26/2023
Misc
Informational
07/26/2023
Building (2)
Resolved
07/26/2023
Underslab Plumbing Inspection - Commercial Failed 8/4/2023 8/4/2023 08/04/2023
Misc
Corrective Action Required
08/04/2023
INSPECTION DENIED no address posted
Underslab Plumbing Inspection - Commercial Passed 8/7/2023 08/07/2023
Misc
Resolved
08/07/2023
Underslab Electrical Inspection - Commercial Passed 8/11/2023 08/11/2023
Misc
Informational
08/11/2023
BUILDING 2 OK
Foundation Inspection - Commercial Not Ready 11/2/2023 (9:00) 11/2/2023 11/02/2023
Miscellaneous Correction
Corrective Action Required
11/02/2023
City approved plans were not on site for reference guide. (Not ready)
Foundation Inspection - Commercial Passed 11/7/2023 11/07/2023
Miscellaneous Correction
Resolved
11/07/2023
City approved plans were not on site for reference guide. (Not ready)
Misc
Informational
11/07/2023
- inspected steel for front porch building 2
Foundation Inspection - Commercial Passed 11/13/2023 11/13/2023
Misc
Informational
11/13/2023
Last 2 on building 2
Gas Service Inspection - Commercial Passed 2/5/2024 02/05/2024
Misc
Informational
02/05/2024
OK UNITS: 455,457,459,461,463,465,467
Gas Service Inspection - Commercial Failed 2/16/2024 02/16/2024
Misc
Corrective Action Required
02/16/2024
Test pressure not holding for units 463 and 467. All other units are OK
All Rough Inspection - Commercial Failed 2/16/2024 2/16/2024 02/16/2024
Misc
Corrective Action Required
02/16/2024
** Unit 457, 459, 461, and 463 not inspected ** Complete framing for rear balcony per engineer *Fb = fire block Unit 455: -Complete installing all windows -Install all required hold downs per plan -Protect plumbing at 1st floor bedroom bottom wall plate -Provide receptacle within 3ft of 1st floor study/bedroom bath sink -Anchor all sill plates per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space -Install fire pad per listing requirement -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Fb duct chase from horizontal spaces -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Secure 3rd floor rear bathroom sink circuit per code -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Fb dryer duct penetration of floor -Use 3/4” sheathing for fire blocking; seal gaps Unit 465: -Complete installing all windows -Install all required hold downs per plan -Install puffy pad per listing requirement. Fully cover the boxes -Leave gap between stairs and common fire separation wall for fire GB -Fb double-stud garage and fire separation wall vertically at max 10 ft intervals -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Dryer duct cannot be distorted from its round shape -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Complete installing bathroom tub -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb dyer penetration of wall plate -Provide a wall receptacle in master bedroom for wall wider than 2 ft -Fb space at rear bathroom from attic Unit south 467: -Complete installing all windows -Install all required hold downs per plan -Anchor all sill plate per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space; Fb duct chase from horizontal spaces; Fb bathroom wall from ceiling space -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Protect vent pipe at kitchen exterior wall top plate -Fb bath fan duct penetrations of wall plates; Fb hole at master bedroom bottom wall plate; Fb dryer duct penetration of floor -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Protect vent pipe at rear bedroom exterior wall top plates -Strap top plates where bored more than 50% -Relocate attic access opening to location that allows min 30” of headroom clearance
All Rough Inspection - Commercial Failed 2/20/2024 02/20/2024
Misc
Corrective Action Required
02/16/2024
** Unit 463 not inspected ** Complete framing for rear balcony per engineer *Fb = fire block Unit 455: -Complete installing all windows -Install all required hold downs per plan -Protect plumbing at 1st floor bedroom bottom wall plate -Provide receptacle within 3ft of 1st floor study/bedroom bath sink -Anchor all sill plates per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space -Install fire pad per listing requirement -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Fb duct chase from horizontal spaces -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Secure 3rd floor rear bathroom sink circuit per code -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Fb dryer duct penetration of floor -Use 3/4” sheathing for fire blocking; seal gaps Unit 465: -Complete installing all windows -Install all required hold downs per plan -Install puffy pad per listing requirement. Fully cover the boxes -Leave gap between stairs and common fire separation wall for fire GB -Fb double-stud garage and fire separation wall vertically at max 10 ft intervals -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Dryer duct cannot be distorted from its round shape -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Complete installing bathroom tub -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb dyer penetration of wall plate -Provide a wall receptacle in master bedroom for wall wider than 2 ft -Fb space at rear bathroom from attic Unit south 467: -Complete installing all windows -Install all required hold downs per plan -Anchor all sill plate per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space; Fb duct chase from horizontal spaces; Fb bathroom wall from ceiling space -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Protect vent pipe at kitchen exterior wall top plate -Fb bath fan duct penetrations of wall plates; Fb hole at master bedroom bottom wall plate; Fb dryer duct penetration of floor -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Protect vent pipe at rear bedroom exterior wall top plates -Strap top plates where bored more than 50% -Relocate attic access opening to location that allows min 30” of headroom clearance
Misc
Corrective Action Required
02/20/2024
455 sw Longview ** Unit 463 not inspected ** Complete framing for rear balcony per engineer - FRONT STOOP TO BE 36” all *Fb = fire block 2/20/24 **UNIT 457 - Fb top plate penetrations second floor refrigerator wall - Nail double girder to code at second floor top of stairs - Provide Boca plate at DWV kitchen bottom plate - Fb floor around 4” duct in HVAC chase second floor - Fb floor and top plate penetrations of double 4” duct at top of stairs 3rd floor - Repair damaged duct in attic space above bathroom - Seal gaps at third floor chase at stairs op plate fire blocking - Provide missing windows - Fire blocking to be 3/4” through out - Provide outlet at second floor stair wall , over 6’ ** UNIT 459 - Provide Boca plate for SE cable below electrical panel - Fb top of mechanical room to prevent vertical to horizontal flame spread - Complete balcony framing - Window second floor stairs to be tempered (at final) - Fb penetration second floor toilet top plate - Protect DWV kitchen top and bottom - Fb floor penetrations in second floor HVAC chase - Complete vent ductwork third floor toilet - Complete fire blocking third floor front wall to demise wall in chase - Seal penetration above top plate demise wall master closet - Provide missing windows - Fb DWV third floor back closet top plate - Fb dryer vent third floor laundry **UNIT 461 - Fb vertically every 10’ demise wall garage and first floor - Window to be tempered second floor front of building with in 6’ of stairs - Solid block sheeting break by kitchen sink - Add outlet second floor stairs wall at front. Over 6’ - Provide missing windows - Fb floor and top plate third floor landing bathroom wall @ (2) 4” ducts -
All Rough Inspection - Commercial Failed 2/21/2024 02/21/2024
Misc
Corrective Action Required
02/20/2024
** Complete framing for rear balcony per engineer *Fb = fire block Unit 455: -Complete installing all windows -Install all required hold downs per plan -Protect plumbing at 1st floor bedroom bottom wall plate -Provide receptacle within 3ft of 1st floor study/bedroom bath sink -Anchor all sill plates per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space -Install fire pad per listing requirement -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Fb duct chase from horizontal spaces -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Secure 3rd floor rear bathroom sink circuit per code -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Fb dryer duct penetration of floor -Use 3/4” sheathing for fire blocking; seal gaps Unit 465: -Complete installing all windows -Install all required hold downs per plan -Install puffy pad per listing requirement. Fully cover the boxes -Leave gap between stairs and common fire separation wall for fire GB -Fb double-stud garage and fire separation wall vertically at max 10 ft intervals -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Dryer duct cannot be distorted from its round shape -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Complete installing bathroom tub -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb dyer penetration of wall plate -Provide a wall receptacle in master bedroom for wall wider than 2 ft -Fb space at rear bathroom from attic Unit south 467: -Complete installing all windows -Install all required hold downs per plan -Anchor all sill plate per code -Leave gap between stairs and common fire separation wall for fire GB -Fb stair stringer space from horizontal space; Fb duct chase from horizontal spaces; Fb bathroom wall from ceiling space -Wall space receptacle must be within 6 ft of any point along the duct chase/stair wall. FYI: the guardrail adjacent to stair is considered as a wall space -Protect vent pipe at kitchen exterior wall top plate -Fb bath fan duct penetrations of wall plates; Fb hole at master bedroom bottom wall plate; Fb dryer duct penetration of floor -Protect roof deck within 4 ft of firewall per IRC R302.2.4(2) exception. This protection must extend min 4 ft out from side of common fire separation wall -Install TJC57 support at corner trusses connection to girder truss -Nail together girder truss per truss detail (nail @ 7” oc) -Protect vent pipe at rear bedroom exterior wall top plates -Strap top plates where bored more than 50% -Relocate attic access opening to location that allows min 30” of headroom clearance
Misc
Corrective Action Required
02/20/2024
455 sw Longview ** Complete framing for rear balcony per engineer - FRONT STOOP TO BE 36” all *Fb = fire block 2/20/24 **UNIT 457 - Fb top plate penetrations second floor refrigerator wall - Nail double girder to code at second floor top of stairs - Provide Boca plate at DWV kitchen bottom plate - Fb floor around 4” duct in HVAC chase second floor - Fb floor and top plate penetrations of double 4” duct at top of stairs 3rd floor - Repair damaged duct in attic space above bathroom - Seal gaps at third floor chase at stairs op plate fire blocking - Provide missing windows - Fire blocking to be 3/4” through out - Provide outlet at second floor stair wall , over 6’ ** UNIT 459 - Provide Boca plate for SE cable below electrical panel - Fb top of mechanical room to prevent vertical to horizontal flame spread - Complete balcony framing - Window second floor stairs to be tempered (at final) - Fb penetration second floor toilet top plate - Protect DWV kitchen top and bottom - Fb floor penetrations in second floor HVAC chase - Complete vent ductwork third floor toilet - Complete fire blocking third floor front wall to demise wall in chase - Seal penetration above top plate demise wall master closet - Provide missing windows - Fb DWV third floor back closet top plate - Fb dryer vent third floor laundry **UNIT 461 - Fb vertically every 10’ demise wall garage and first floor - Window to be tempered second floor front of building with in 6’ of stairs - Solid block sheeting break by kitchen sink - Add outlet second floor stairs wall at front. Over 6’ - Provide missing windows - Fb floor and top plate third floor landing bathroom wall @ (2) 4” ducts -
Misc
Corrective Action Required
02/21/2024
** UNIT 463 - Fb ceiling of mechanical room - Fb floor penetration second floor toilet room - Fb second floor pantry demise wall studs - Fb top of HVAC chase second floor - Fb floor penetrations HVAC chase second floor - Window at second floor stairs front building to be tempered ( at final) - Provide Boca plate at third floor laundry supply line - Fb floor penetration laundry dryer duct - At chase between third floor laundry and shower,Fb floor around ductwork and top plate to attic space - Provide missing window third floor
All Rough Inspection - Commercial Failed 3/5/2024 3/5/2024 03/05/2024
Misc
Corrective Action Required
02/21/2024
*Fb = fire block Unit 455: -Complete installing all windows Unit 465: -Complete installing all windows -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb dyer penetration of wall Unit south 467: -Complete installing all windows -Fb duct chase from horizontal spaces; Fb bathroom wall from ceiling space -Fb bath fan duct penetrations of wall plates; Fb hole at master bedroom bottom wall plate; Fb dryer duct penetration of floor
Misc
Corrective Action Required
02/21/2024
455 sw Longview *Fb = fire block 2/20/24 **UNIT 457 - Fb top plate penetrations second floor refrigerator wall - Fb floor and top plate penetrations of double 4” duct at top of stairs 3rd floor - Provide missing windows ** UNIT 459 - Provide missing windows - Fb floor penetrations at second floor HVAC chase **UNIT 461 - Fb vertically every 10’ demise wall garage and first floor - Window to be tempered second floor front of building with in 6’ of stairs - Solid block sheeting break by kitchen sink - Add outlet second floor stairs wall at front. Over 6’ - Provide missing windows - Fb floor and top plate third floor landing bathroom wall @ (2) 4” ducts -
Misc
Corrective Action Required
02/21/2024
** UNIT 463 - Fb floor penetration second floor toilet room (sprinker lines) - Fb top of HVAC chase second floor - Fb floor penetration laundry dryer duct - At wall third floor top of stairs and tub ,Fb floor around ductwork and top plate to attic space - Provide missing window third floor
All Rough Inspection - Commercial Failed 3/8/2024 3/8/2024 03/08/2024
Misc
Resolved
03/08/2024
Misc
Resolved
03/08/2024
Misc
Resolved
03/08/2024
Misc
Corrective Action Required
03/08/2024
*Fb = fire block Unit 455: -Complete installing all windows **UNIT 457 - Provide missing windows ** UNIT 459 - Provide missing windows **UNIT 461 - Provide missing windows ** UNIT 463 - Fb top of HVAC chase second floor - F b At wall third floor top of stairs and tub , - Fb floor around ductwork and top plate to attic space - Provide missing window third floor Unit 465: -Complete installing all windows -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb Unit south 467: -Complete installing all windows -Fb duct chase from horizontal spaces; second floor
All Rough Inspection - Commercial Failed 3/13/2024 3/13/2024 03/13/2024
Misc
Corrective Action Required
03/08/2024
*Fb = fire block Unit 455: -Complete installing all windows **UNIT 457 - Provide missing windows ** UNIT 459 - Provide missing windows **UNIT 461 - Provide missing windows ** UNIT 463 - Fb top of HVAC chase second floor - F b At wall third floor top of stairs and tub , - Fb floor around ductwork and top plate to attic space - Provide missing window third floor Unit 465: -Complete installing all windows -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb Unit south 467: -Complete installing all windows -Fb duct chase from horizontal spaces; second floor
All Rough Inspection - Commercial Failed 03/13/2024
Misc
Corrective Action Required
03/13/2024
*Fb = fire block Unit 455: -Complete installing all windows **UNIT 457 - Provide missing windows ** UNIT 459 - Provide missing windows **UNIT 461 - Provide missing windows ** UNIT 463 - Fb top of HVAC chase second floor - F b At wall third floor top of stairs and tub , - Fb floor around ductwork and top plate to attic space - Provide missing window third floor Unit 465: -Complete installing all windows -Fb 3rd duct chase at floor and ceiling. Use 3/4” sheathing for fire blocking and seal all gaps; fb Unit south 467: -Complete installing all windows -Fb duct chase from horizontal spaces; second floor **OK to insulate-DO NOT COVER INSPECTION ITEMS
All Rough Inspection - Commercial Failed 3/15/2024 3/15/2024 03/15/2024
Misc
Corrective Action Required
03/13/2024
Unit 455: -Complete installing all windows **UNIT 457 - Provide missing windows ** UNIT 459 - Provide missing windows **UNIT 461 - Provide missing windows ** UNIT 463 - Provide missing window third floor Unit 465: -Complete installing all windows Unit south 467: -Complete installing all windows **OK to insulate
Rated Assembly Inspection Failed 3/26/2024 3/26/2024 03/26/2024
Misc
Corrective Action Required
03/26/2024
Rated assembly inspection: -467 bathroom 3rd floor north wall insufficient screws -465 PASSED -463 northwest corner 8ft up garage wall insufficient screws -461 PASSED -459 PASSED -457 PASSED -455 PASSED
Rated Assembly Inspection Passed 3/27/2024 3/27/2024 03/27/2024
Misc
Informational
03/27/2024
Rated assembly inspection: -467 PASSED -465 PASSED -463 PASSED -461 PASSED -459 PASSED -457 PASSED -455 PASSED
Electrical Service Inspection Failed 4/10/2024 4/10/2024 04/10/2024
E110.22 Identification of disconnection means
Corrective Action Required
04/10/2024
Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose os evident. The marking shall be of sufficient durability to withstand the environment involved. Where circuit breakers or fuses are applied in compliance with the series combination ratings marked on the equipment by the manufacturer, the equipment enclosure(s) shall bbe marked in the field to indicate the equipment has been applied with a series combination rating. The marking shall be readily visible and state the following: CAUTION-SERIES COMBINATION SYSTEM RATED ___AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. EACH UNIT
Electrical Service Inspection Passed 4/16/2024 4/16/2024 04/16/2024
E110.22 Identification of disconnection means
Resolved
04/16/2024
Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose os evident. The marking shall be of sufficient durability to withstand the environment involved. Where circuit breakers or fuses are applied in compliance with the series combination ratings marked on the equipment by the manufacturer, the equipment enclosure(s) shall bbe marked in the field to indicate the equipment has been applied with a series combination rating. The marking shall be readily visible and state the following: CAUTION-SERIES COMBINATION SYSTEM RATED ___AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. EACH UNIT
Occupancy Inspection - Engineering Failed 8/20/2024 8/20/2024 08/20/2024
Misc
Corrective Action Required
08/20/2024
8-20-24 DP. This occupancy fails for the same reasons as building 1. -Clean up roads, fix erosion control -Vegetation -Surface Curry Road down to Brummel Rd and also fix the bad spots in the road. -Pour approach to the alleyway.
Occupancy Inspection - Codes Commercial Failed 8/20/2024 8/20/2024 08/20/2024
Misc
Corrective Action Required
08/20/2024
All units *** - Final grading and sod - Provide gutters and down spouts - Splash blocks - Uncover water meters - Complete deck railing - Missing locks and secondary locks all units - Provide tamper proof caps at A/C compressors - Provide 3” security screws at front entry (2) per hinge, and in strike plates all units - Oven anti tipping devices installed but not set in 455 - Permanent address posted - Provide handrail at front steps - Uncover water meter - Stars at garage over 3/8” variance and risers over 7 3/4” - 18” of copper required before pex at water heater - Handrail to low at stairs second floor to third level - Third floor back bathroom window is to be tempered 457 - Uncover water meter - Permanent address posted - Provide handrail at front steps - outlet in mechanical room to be GFCI or single pole with label - Stars at garage over 3/8” variance and risers over 7 3/4” - 18” of copper required before pex at water heater - Fire block penetration at line set in mechanical room - Missing outlet cover in kitchen - Handrail low at top of stairs third floor - Third floor bathroom window behind door to be tempered 459 - - Uncover water meter - Permanent address posted - Provide handrail at front steps - outlet in mechanical room to be GFCI or single pole with label - Stars at garage over 3/8” variance and risers over 7 3/4” - 18” of copper required before pex at water heater - Handrail at bottom of first floor stairs under 34” - Window at bottom of third floor stairs to be tempered 461 - Permanent address posted - outlet in mechanical room to be GFCI or single pole with label - Stars at garage over 3/8” variance and risers over 7 3/4” - 18” of copper required before pex at water heater - Third floor bathroom back to be tempered door to close 463 - Permanent address posted - outlet in mechanical room to be GFCI or single pole with label - Stars at garage over 3/8” variance and risers over 7 3/4” - 18” of copper required before pex at water heater - Window at bottom of third floor stairs to be tempered 465, 467not inspected ( correct alike items) I will complete on re inspection
All Rough Inspection - Commercial Passed 8/20/2024 08/20/2024
Misc
Resolved
08/20/2024
Unit 455: -Complete installing all windows **UNIT 457 - Provide missing windows ** UNIT 459 - Provide missing windows **UNIT 461 - Provide missing windows ** UNIT 463 - Provide missing window third floor Unit 465: -Complete installing all windows Unit south 467: -Complete installing all windows **OK to insulate
Erosion Control Inspection Residential Partial 8/20/2024 08/20/2024
Misc
Corrective Action Required
08/20/2024
- ok at time of inspection
Sprinkler - Hydrostatic Test Passed 08/21/2024
Occupancy Inspection - Planning Temporary C of O 8/20/2024 8/20/2024 09/11/2024
Corrective Action Required
09/11/2024
LANDSCAPING. Staff will confirm compliance with the approved landscape plan prior to the issuance of Final Occupancy.
Occupancy Inspection - Codes Commercial Failed 9/11/2024 9/11/2024 09/11/2024
Misc
Resolved
09/11/2024
Misc
Corrective Action Required
09/11/2024
Misc
Corrective Action Required
09/11/2024
All units *** - Provide gutters and down spouts - Splash blocks 455 - outlet in mechanical room to be GFCI or single pole with label - Third floor back bathroom window is to be tempered ( covered with plexiglass) 457 - Fire block penetration at line set in mechanical room - Third floor bathroom window behind door to be tempered ( covered with plexiglass) - Provide tamper proof caps at A/C compressors - outlet in mechanical room to be GFCI or single pole with label 459 - outlet in mechanical room to be GFCI or single pole with label 461 - outlet in mechanical room to be GFCI or single pole with label - Stars at garage over 3/8” variance - 18” of cop - Third floor bathroom back to be tempered door to close 463 - outlet in mechanical room to be GFCI or single pole with label 465, - missing switch cover at garage - Fire block penetration at line set - Label single outlet non GFCI in mechanical room - Variance of rise over 3/8” on basement stairs - Provide smoke detector top floor back bedroom 467 - cover missing on outlet in garage - Label outlet non gfci in mechanical room - Vent fan at master shower not operating - Too floor back bathroom window to be tempered ( covered by plexiglass)
Occupancy Inspection - Engineering Temporary C of O 9/11/2024 9/11/2024 09/11/2024
Misc
Corrective Action Required
08/20/2024
8-20-24 DP. This occupancy fails for the same reasons as building 1. -Clean up roads, fix erosion control -Vegetation -Surface Curry Road down to Brummel Rd and also fix the bad spots in the road. -Pour approach to the alleyway.
Miscellaneous Correction
Corrective Action Required
09/11/2024
9-11-24 DP. -There is 1 panel in the 10' sidewalk that needs replaced -Still two small sections of curb needing replaced The sidewalk on the north side of the buildings that runs down to the corner or Curry and Brummel is in the plans to be ADA compliant. The contractor installed 1 step in the sidewalk before the indicator pad. This is not ADA compliant and will need to be addressed. This issue will not stop buildings 1 and 2 from getting TCO from FEI. When the contractor is ready to address the issue with the sidewalk, I am willing to meet onsite and strategize. TCO still granted.
Erosion Control Inspection Residential Passed 9/12/2024 09/12/2024
Misc
Resolved
09/12/2024
- ok at time of inspection
Occupancy Inspection - Codes Commercial Ready for Temp CO 9/13/2024 9/12/2024 09/12/2024
Misc
Resolved
09/12/2024
Misc
Corrective Action Required
09/11/2024
All units *** - Provide gutters and down spouts - Splash blocks 455,457,461- - Third floor bathroom back to be tempered door to close ( covered with plexiglass) 459,463,465,467-ok Re-inspecctions shall be schedule before 30 days. TCo extension request required if not complete in 30day to extend the TCO
Sewer Service Inspection Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP. All sewer services are have been installed with all repairs complete.
Sewer Service Inspection Passed 10/31/2024
Misc
Informational
10/31/2024
10-31-24 DP. All sewer services are have been installed with all repairs complete.
Occupancy Inspection - Engineering Passed 10/31/2024 10/31/2024 10/31/2024
Misc
Corrective Action Required
08/20/2024
8-20-24 DP. This occupancy fails for the same reasons as building 1. -Clean up roads, fix erosion control -Vegetation -Surface Curry Road down to Brummel Rd and also fix the bad spots in the road. -Pour approach to the alleyway. 10-31-24 DP. All punch list items have been completed.
Occupancy Inspection - Codes Commercial Full C of O 11/18/2024 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
All units *** - Provide gutters and down spouts
Documents & Images
Date Uploaded File Type Document Name
05/26/2023 Receipt Receipt for transaction:2023-003701
05/26/2023 Letter DS Building Permit
06/19/2023 Receipt Receipt for transaction:2023-004560
06/30/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
08/04/2023 Letter INSPECTION SUMMARY
08/07/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
11/02/2023 Letter INSPECTION SUMMARY
11/02/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/13/2023 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Receipt Receipt for transaction:2024-007661
09/12/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/12/2024 Receipt Receipt for transaction:2024-007663
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter Codes Final Certificate of Occupancy
11/18/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home