Summary
PRCOM20225103
Building Permit - Commercial
Certificate of Occupancy
SOCIAL PROPERTIES LLC
CHANGE OF TENANT
RETAIL STORE FOR SALE OF BOOKS AND OTHER ITEMS *Invite Planner to final to verify screening of equipment
10/11/2022
12/06/2022
04/17/2023
08/02/2023
Locations
Contacts
SOCIAL PROPERTIES LLC, Address:807 SW OLDHAM PKWY  
Mark Deaton, Address:4409 SE Secretariat Dr, Phone:(816) 401-9050  
FINN CONSTRUCTION LLC, Address:1039 NE HUNTERS RDG, Phone:(816) 835-2091  
COPELAND ELECTRICAL, Address:2520 LEES SUMMIT RD, Phone:(816) 461-3636  
STEPHEN DELGADO, Address:1039 NE HUNTERS RIDGE, Phone:(816) 835-2091  
ERIC KJELSHUS ENERGY, Address:25001 E OUTER BELT RD, Phone:(816) 537-5100  
Elsewhere Apothecary & Bookstore LLC, Address:809 OLDHAM PKWY SW, Phone:(816) 726-0079  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 11/22/2022 12/02/2022
Joe Frogge
LC - General Contractor
Resolved
12/02/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Resolved
12/02/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. (Electrical and Mechanical/HVAC subs required)
Building Plan Review Approved 12/01/2022 11/22/2022
Joe Frogge
IBC 1011.11 Handrails - handrails at stairways
Resolved
11/22/2022

2018 IBC 1011.11 Handrails. Flights of stairways shall have handrails on each side and shall comply with Section 1014. Where glass is used to provide the handrail, the handrail shall also comply with Section 2407. (see code for exceptions) Action required: Provide handrail on both sides of stairs.
ICC A117.1 904.3 Sales and Service Counters
Resolved
11/22/2022

ICC A117.1 Section 904.3 Sales and service counters and windows. Sales and service counters and windows shall comply with Section 904.3.1 and either 904.3.2 or 904.3.3. Where counters are provided, the accessible portion of the countertop shall extend the same depth as the public portion of the sales and service countertop provided for standing customers. (see code for exception) 904.3.1 Vertical barriers. At service windows or service counters, any vertical barrier between service personnel and customers shall be at a height of 43 inches maximum above the floor. (see code for exception regarding security glazing) 904.3.2 Parallel Approach. A portion of the public use side of the counter surface 36 inches minimum in length and 26 inches minimum and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a parallel approach adjacent to the accessible counter shall be provided. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12 inches minimum. (see code for exception) 904.3.3 Forward Approach. A portion of the public use side of the counter surface 30 inches minimum in length and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a forward approach to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12” minimum. Action required: Modify plans to comply. At least 36" length of checkout counter to be maximum 36" tall.
IBC 2902.3 Employee and public toilet facilities - access to public toilet
Resolved
11/22/2022

2018 IBC 2902.3 Employee and public toilet facilities. For structures and tenant spaces intended for public utilization, customers, patrons and visitors shall be provided with public toilet facilities. Employees associated with structures and tenant spaces shall be provided with toilet facilities. The number of plumbing fixtures located within the required toilet facilities shall be provided in accordance with Section 2902 for all users. Employee toilet facilities shall be either separate or combined employee and public toilet facilities. Exception: Public toilet facilities shall not be required for: 1. Parking garages where operated without parking attendants. 2. Structures and tenant spaces intended for quick transactions, including takeout, pickup and drop-off, having a public access area less than or equal to 300 square feet. Action required: Remove note stating "no public restrooms."
Fire Plan Review Approved with Conditions 12/01/2022 11/22/2022
Joe Frogge
Misc
Corrective Action Required
11/22/2022

The exterior door locks shall be openable from the inside without a key, tool, or special knowledge. Provide thumblatches if needed. Verified at inspection.
Fire Plan Review Approved with Conditions 10/21/2022 10/18/2022
Jim Eden
Misc
Corrective Action Required
10/18/2022

The exterior door locks shall be openable from the inside without a key, tool, or special knowledge. Provide thumblatches if needed. Verified at inspection.
Building Plan Review Rejected 10/21/2022 10/11/2022
Joe Frogge
IBC 1011.11 Handrails - handrails at stairways
Corrective Action Required
10/11/2022

2018 IBC 1011.11 Handrails. Flights of stairways shall have handrails on each side and shall comply with Section 1014. Where glass is used to provide the handrail, the handrail shall also comply with Section 2407. (see code for exceptions) Action required: Provide handrail on both sides of stairs.
ICC A117.1 904.3 Sales and Service Counters
Corrective Action Required
10/11/2022

ICC A117.1 Section 904.3 Sales and service counters and windows. Sales and service counters and windows shall comply with Section 904.3.1 and either 904.3.2 or 904.3.3. Where counters are provided, the accessible portion of the countertop shall extend the same depth as the public portion of the sales and service countertop provided for standing customers. (see code for exception) 904.3.1 Vertical barriers. At service windows or service counters, any vertical barrier between service personnel and customers shall be at a height of 43 inches maximum above the floor. (see code for exception regarding security glazing) 904.3.2 Parallel Approach. A portion of the public use side of the counter surface 36 inches minimum in length and 26 inches minimum and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a parallel approach adjacent to the accessible counter shall be provided. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12 inches minimum. (see code for exception) 904.3.3 Forward Approach. A portion of the public use side of the counter surface 30 inches minimum in length and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a forward approach to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12” minimum. Action required: Modify plans to comply. At least 36" length of checkout counter to be maximum 36" tall.
IBC 2902.3 Employee and public toilet facilities - access to public toilet
Corrective Action Required
10/11/2022

2018 IBC 2902.3 Employee and public toilet facilities. For structures and tenant spaces intended for public utilization, customers, patrons and visitors shall be provided with public toilet facilities. Employees associated with structures and tenant spaces shall be provided with toilet facilities. The number of plumbing fixtures located within the required toilet facilities shall be provided in accordance with Section 2902 for all users. Employee toilet facilities shall be either separate or combined employee and public toilet facilities. Exception: Public toilet facilities shall not be required for: 1. Parking garages where operated without parking attendants. 2. Structures and tenant spaces intended for quick transactions, including takeout, pickup and drop-off, having a public access area less than or equal to 300 square feet. Action required: Remove note stating "no public restrooms."
Licensed Contractors Rejected 10/21/2022 10/11/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
10/11/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
10/11/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. (Electrical and Mechanical/HVAC subs required)
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $50.00 $50.00 Paid 11/21/2022
$0.00
Commercial Excise Tax Fee $990.00 $990.00 Paid 11/21/2022
$882.75
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/12/2022
COMPLETE ALL MEPS AND FRAMING FOR INSPECTION
Electrical Service Inspection Passed 2/13/2023 2/13/2023 02/13/2023
Occupancy Inspection - Fire Passed 8/2/2023 8/2/2023 08/02/2023
Occupancy Inspection - Codes Commercial Full C of O 8/2/2023 8/2/2023 08/02/2023
Documents & Images
Date Uploaded File Type Document Name
10/11/2022 Application Form Commercial Permit Application Elsewhere Apothecary Bookstore
10/11/2022 Plans 809 SW Oldham Pkwy Elsewhere - Permit Dwg Set
10/18/2022 Letter Fire Building Plan Review
10/19/2022 Letter DS P/R Corrections Document
10/19/2022 Letter License Tax Bill
11/21/2022 Receipt Receipt for transaction:2022-009077
11/21/2022 Drawing 22_1118 Sht 2 Rev 1
11/21/2022 Drawing 22_1118 Sht 3 - Rev 1
11/22/2022 Approved Plans approved - 809 SW Oldham Pkwy Elsewhere - Permit Dwg Set
12/06/2022 Letter DS Building Permit
12/12/2022 Letter INSPECTION SUMMARY
02/13/2023 Letter INSPECTION SUMMARY
07/03/2023 Letter Codes 140 Day Letter
08/02/2023 Letter Field Certificate of Occupancy
08/02/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home