Permit Application Status

PRCOM20220426


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20220426
Building Permit - Commercial
Certificate of Occupancy
RENOURISH LLC
CHANGE OF TENANT
TENANT FINSH FOR NUTRITIONAL COUNSELING OFFICE - INCLUDES SOME SITE WORK ***FIRE RATED ASSEMBLY OMITTED PER CMR
02/02/2022
04/27/2022
08/10/2022
02/23/2023
Locations
Contacts
WHD Management Inc., Address:PO Box 1059   
anthony@cammconstruction.com, Address:anthony@cammconstruction.com, Phone:(816) 607-3608  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit B, Phone:(816) 249-2270  
RENOURISH LLC, Address:102 SW 2ND ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved 02/24/2022 02/18/2022
Jim Eden
Misc
Resolved
02/18/2022

What is the plan for the upstairs and basement?
Portable fire extinguishers - general
Resolved
02/18/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Note- The fire extinguisher is required by the 2018 International Fire Code and not the Wisconsin Fire Prevention Code.
Building Plan Review Approved 02/24/2022 02/16/2022
Joe Frogge
Code analysis required
Resolved
02/16/2022

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Add use and analysis of other floor levels to "Code Information."
IBC 1104.3 Connected spaces - accessibility
Resolved
02/16/2022

2018 IBC 1104.3 Connected spaces. When a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and the public way. (see code for exceptions) Action required: Show how one or more entry/egress is accessible.
Licensed Contractors Approved 02/24/2022 02/16/2022
Joe Frogge
LC - General Contractor
Resolved
02/16/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Resolved
02/16/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 02/14/2022 02/11/2022
Jim Eden
Misc
Corrective Action Required
02/11/2022

What is the plan for the upstairs and basement?
Portable fire extinguishers - general
Corrective Action Required
02/11/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Note- The fire extinguisher is required by the 2018 International Fire Code and not the Wisconsin Fire Prevention Code.
Building Plan Review Rejected 02/14/2022 02/10/2022
Joe Frogge
Code analysis required
Corrective Action Required
02/10/2022

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Add use and analysis of other floor levels to "Code Information."
IBC 1104.3 Connected spaces - accessibility
Corrective Action Required
02/10/2022

2018 IBC 1104.3 Connected spaces. When a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and the public way. (see code for exceptions) Action required: Show how one or more entry/egress is accessible.
Licensed Contractors Rejected 02/14/2022 02/10/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
02/10/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
02/10/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Commercial $300.00 $300.00 Paid 04/26/2022
$3,231.36
Commercial Excise Tax Fee $1,905.00 $1,905.00 Paid 04/12/2022
$1,077.12
Paved Surface Inspection Fee $174.77 $174.77 Paid 04/26/2022
Site Grading Fee $27.17 $27.17 Paid 04/26/2022
Right of Way Permit Fee $85.00 $85.00 Paid 04/26/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 11/30/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 12/19/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 02/22/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Site Visit Partial 05/26/2022
Misc
Informational
05/26/2022
5/26/22 Thursday Pre-Con with contractor and project manager onsite. Everything was okayed for contractor to proceed with preparing for work.
Grading/Excavation/Fill Inspection Partial 08/22/2022
Misc
Informational
08/22/2022
08/22/22 Monday JMJ ( TempStop ) Contractor began work on site 08/19/22 Friday. Excavation of site for removal of existing driveway and grading for parking lot & detention basin.
Storm Sewer Construction Inspection Partial 08/23/2022
Misc
Informational
08/23/2022
08/23/22 Tuesday JMJ (TempStop) Contractor is install 4”corrugated black storm pipe and detention basin. Contractor excavated existing clay storm pipe.
Grading/Excavation/Fill Inspection Passed 08/24/2022
Misc
Informational
08/22/2022
08/22/22 Monday JMJ ( TempStop ) Contractor began work on site 08/19/22 Friday. Excavation of site for removal of existing driveway and grading for parking lot & detention basin. 08/24/22 Wednesday JMJ ( Precision Construction ) Backfilled storm drain and basin area.
Storm Sewer Construction Inspection Passed 08/24/2022
Misc
Informational
08/23/2022
08/23/22 Tuesday JMJ (TempStop) Contractor is install 4”corrugated black storm pipe and detention basin. Contractor excavated existing clay storm pipe. 08/24/22 Wednesday JMJ ( Precision Construction ) Contractor backfilled the HPDE corrugated storm pipe and detention basin.
Sidewalk Inspection Partial 08/31/2022
Misc
Informational
08/31/2022
08/31/22 Wednesday JMJ ( Precision Construction ) Contractor installed redesign ADA compliance sidewalk all changes shall be reflected on As-Built.
Driveway Inspection Partial 09/01/2022
Misc
Informational
09/01/2022
09/01/22 Thursday JMJ ( Precision Construction ) Contractor continued to frame driveway/parking lot for concrete pour.
Driveway Inspection Partial 9/6/2022 9/6/2022 09/06/2022
Misc
Informational
09/01/2022
09/01/22 Thursday JMJ ( Precision Construction ) Contractor continued to frame driveway/parking lot for concrete pour. 09/06/22 Tuesday JMJ ( Percision Construction ) Contractor poured driveway it appears that right-away agents allowed contractor to keep water meter in parking lot area.
Driveway Inspection Partial 09/07/2022
Misc
Informational
09/06/2022
09/01/22 Thursday JMJ ( Precision Construction ) Contractor continued to frame driveway/parking lot for concrete pour. 09/06/22 Tuesday JMJ ( Percision Construction ) Contractor poured driveway it appears that right-away agents allowed contractor to keep water meter in parking lot area. 09/07/22 Wednesday JMJ ( Precision Construction ) Contractor poured the entrance for the driveway approach and match existing sidewalk on the West & Eastside driveway.
Pavement-Surface Passed 10/31/2022
Pavement-Aggregate Base Passed 10/31/2022
Pavement-Curb Construction Passed 10/31/2022
Pavement-Stabilized Subgrade Passed 10/31/2022
ESC - (Vegetation/Ground Cover) Passed 10/31/2022
In-wall Inspection Failed 10/31/2022 10/31/2022 10/31/2022
Miscellaneous Correction
Corrective Action Required
10/31/2022
NO INSPECTION CAMM CONSTRUCTION IS NOT THE CONTRACTOR OBTAIN PERMIT IN THE NAME OF CONTRACTOR'S THAT PERFORMED WORK PRRPR 20213876, 20213534, 20210740 ALL PERMITS FOR THIS ADDRESS
Miscellaneous Correction
Corrective Action Required
10/31/2022
(1012.8 2018 IBC ) RAMPS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE HANDRAILS ON BOTH SIDES HANDRAILS SHALL COMPLY WITH SECTION 1014 PROVIDE GRAB BARS RESTROOM PROVIDE RESTROOM SIGNAGE
Water Service Inspection Passed 11/30/2022
Sidewalk Inspection Passed 11/30/2022
Misc
Informational
08/31/2022
08/31/22 Wednesday JMJ ( Precision Construction ) Contractor installed redesign ADA compliance sidewalk all changes shall be reflected on As-Built.
Occupancy Inspection - Engineering Passed 11/30/2022 11/30/2022
Misc
Informational
11/30/2022
All items are complete. Full occupancy on our end.
Occupancy Inspection - Codes Commercial Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
-Provide accessible restroom signage 48"-60" aff to braille on latch side of door -Provide open faced toilet seat -Mirror to be max 40" to reflective surface -Non absorbant baseboard and wall finish required in restroom min of 48" aff -Stair risers at exterior to be within 3/8" variance
Gas Service Inspection - Commercial Not Ready 11/30/2022
In-wall Inspection Passed 11/30/2022
Miscellaneous Correction
Resolved
11/30/2022
NO INSPECTION CAMM CONSTRUCTION IS NOT THE CONTRACTOR OBTAIN PERMIT IN THE NAME OF CONTRACTOR'S THAT PERFORMED WORK PRRPR 20213876, 20213534, 20210740 ALL PERMITS FOR THIS ADDRESS
Occupancy Inspection - Codes Commercial Failed 11/30/2022
Misc
Corrective Action Required
11/30/2022
-Provide accessible restroom signage 48"-60" aff to braille on latch side of door -Provide open faced toilet seat -Mirror to be max 40" to reflective surface -Non absorbant baseboard and wall finish required in restroom min of 48" aff -Stair risers at exterior to be within 3/8" variance -Mount fire extinguisher
Occupancy Inspection - Fire Passed 11/30/2022 11/30/2022 11/30/2022
Corrective Action Required
11/30/2022
All life safety was appropriate. Okay to occupy with approval from codes.
Occupancy Inspection - Codes Commercial Ready for Temp CO 12/13/2022 12/13/2022 12/13/2022
Misc
Corrective Action Required
11/30/2022
-Stair risers at exterior to be within 3/8" variance
Occupancy Inspection - Codes Commercial Failed 1/19/2023 01/19/2023
Misc
Corrective Action Required
12/13/2022
-Stair risers at exterior to be within 3/8" variance **1/19/23 TCO has expired. Emailed and called contractor on 1/18/23 with no replies. Permit has been placed in NOV status. R. Popp
Occupancy Inspection - Codes Commercial Ready for Temp CO 02/21/2023
Misc
Corrective Action Required
01/19/2023
-Stair risers at exterior to be within 3/8" variance **1/19/23 TCO has expired. Emailed and called contractor on 1/18/23 with no replies. Permit has been placed in NOV status. R. Popp
Occupancy Inspection - Codes Commercial Full C of O 2/23/2023 2/23/2023 02/23/2023
Misc
Resolved
02/23/2023
-Stair risers at exterior to be within 3/8" variance **1/19/23 TCO has expired. Emailed and called contractor on 1/18/23 with no replies. Permit has been placed in NOV status. R. Popp
Documents & Images
Date Uploaded File Type Document Name
02/02/2022 Application Form 220202_ReNourish_LS_Commercial Permit Application
02/02/2022 Plans 22018_220202_ReNourish_G001
02/11/2022 Letter DS P/R Corrections Document
02/16/2022 Letter 22018_220216_ReNourish_102 SW 2nd_Response Letter
02/16/2022 Drawing 22018_220216_ReNourish_102 SW 2nd_G001_resubmittal
02/22/2022 Approved Plans approved drawing
02/22/2022 Letter License Tax Bill
02/23/2022 Letter Fire Building Plan Review
04/12/2022 Receipt Receipt for transaction: 2022-002011
04/12/2022 Code Mod Request ReNourish_Code Modification Request COMMERCIAL
04/26/2022 Receipt Receipt for transaction:2022-002411
04/27/2022 Letter DS Building Permit
04/21/2022 Approved Plans FDP Approved_042122_RENOURISH FDP 4-13-2022
05/26/2022 Letter INSPECTION SUMMARY
08/22/2022 Retention Basin Excavation Area
08/22/2022 Grading of New Parking Lot Area
08/22/2022 Grading & Removal of Existing Driveway
08/22/2022 Letter INSPECTION SUMMARY
08/23/2022 Storm Pipe 1
08/23/2022 Storm Pipe 2
08/23/2022 Retention Basin
08/23/2022 Storm Pipe & Retention Basin
08/23/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
08/24/2022 Storm Pipe Backfilled 1
08/24/2022 Storm Pipe Backfilled 2
08/24/2022 Storm Pipe Backfilled 3
08/24/2022 Storm Drain Basin
08/24/2022 Letter INSPECTION SUMMARY
08/31/2022 Sidewalk & Curbs Concrete Pour
08/31/2022 Curbs Concrete Pour
08/31/2022 Concrete Ticket
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/07/2022 Driveway Approach
09/07/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
11/30/2022 Receipt Receipt for transaction:2022-009186
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter Fire Loss Reduction Form
12/19/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/19/2022 Receipt Receipt for transaction:2022-009569
01/19/2023 Letter INSPECTION SUMMARY
01/19/2023 Letter Codes 10 Day Letter
02/22/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/22/2023 Receipt Receipt for transaction:2023-001039
02/23/2023 Letter Codes Final Certificate of Occupancy
02/23/2023 Letter Field Certificate of Occupancy
01/02/2024 Codes Temporary Certificate of Occupancy48
01/02/2024 Codes Temporary Certificate of Occupancy103
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home