Summary
PRCOM20212613
Building Permit - Commercial
Certificate of Occupancy
CITY OF LEES SUMMIT
NEW TENANT FINISH
TENANT FINISH FOR SALES OF SOAP PRODUCTS
05/20/2021
06/25/2021
08/18/2021
Locations
Contacts
TaraCo, LLC, Address:300 NW 35th St.  
Cpogue@pldi.net, Address:Cpogue@pldi.net  
GREEN FIELD ENERGY GROUP INC, Address:5 SW 4TH ST, Phone:(816) 524-5616  
CS ELECTRIC LLC, Address:1408 W COLLEGE ST, Phone:(816) 423-0061  
GREEN FIELD ENERGY GROUP INC, Address:5 SW 4TH ST, Phone:(816) 524-5616  
IDesign Drafting, Address:1499 Bircham Rd, Phone:(502) 572-0712  
CITY OF LEES SUMMIT, Address:220 SE GREEN ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/14/2021 06/23/2021
Joe Frogge
LC - MEP Subs
Resolved
06/23/2021

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 6/7/21 - acknowledged in letter
Building Plan Review Approved with Conditions 06/14/2021 06/07/2021
Joe Frogge
IBC 602.1 Type of Construction - general
Resolved
06/07/2021

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update Building Code Design Data to show correct construction type which is 5B.
Misc
Resolved
06/07/2021

Unable to determine pipe materials. Action required: Provide pipe material schedule that includes waste, vent, and NG.
Miscellaneous Correction
Resolved
06/07/2021

Electrical power riser diagram doesn't match diagram provided at shell building construction. Action required: Coordinate electric service design with existing conditions and update new diagram accordingly.
Suite address
Corrective Action Required
06/07/2021

This structure has been assigned one address. All suites/apartments shall be assigned an address by the owner which can be numeric, alphabetic or a combination of both. If the building has multiple stories the suite/apartment number shall start with a number representing the floor on which the unit is located. Action required: Provide verification that this tenant will be suite C as submitted. Shell construction indicates 3 suites with the middle suite being B. Designs provided look like this is the middle suite. 6/7/21 - verified by architect/tenant - field verify
Fire Plan Review Approved 06/14/2021 06/07/2021
Michael Weissenbach
Miscellaneous Correction
Resolved
06/07/2021

(Informational Purposes) 1. Knox Box is not required. 2. Building is not sprinkled.
Door operations
Resolved
06/07/2021

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (Verified At Inspection)
Building Plan Review Rejected 06/02/2021 05/24/2021
Joe Frogge
IBC 602.1 Type of Construction - general
Corrective Action Required
05/24/2021

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update Building Code Design Data to show correct construction type which is 5B.
Misc
Corrective Action Required
05/24/2021

Unable to determine pipe materials. Action required: Provide pipe material schedule that includes waste, vent, and NG.
Miscellaneous Correction
Corrective Action Required
05/24/2021

Electrical power riser diagram doesn't match diagram provided at shell building construction. Action required: Coordinate electric service design with existing conditions and update new diagram accordingly.
Suite address
Corrective Action Required
05/24/2021

This structure has been assigned one address. All suites/apartments shall be assigned an address by the owner which can be numeric, alphabetic or a combination of both. If the building has multiple stories the suite/apartment number shall start with a number representing the floor on which the unit is located. Action required: Provide verification that this tenant will be suite C as submitted. Shell construction indicates 3 suites with the middle suite being B. Designs provided look like this is the middle suite.
Licensed Contractors Rejected 06/02/2021 05/24/2021
Joe Frogge
LC - MEP Subs
Corrective Action Required
05/24/2021

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
LC - General Contractor
Resolved
06/01/2021

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact.
Fire Plan Review Approved with Conditions 06/02/2021 05/20/2021
Joe Frogge
Miscellaneous Correction
Corrective Action Required
05/20/2021

(Informational Purposes) 1. Knox Box is not required. 2. Building is not sprinkled.
Door operations
Corrective Action Required
05/20/2021

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (Verified At Inspection)
Fire Plan Review Approved with Conditions 06/02/2021 05/20/2021
Michael Weissenbach
Miscellaneous Correction
Corrective Action Required
05/20/2021

(Informational Purposes) 1. Knox Box is not required. 2. Building is not sprinkled.
Door operations
Corrective Action Required
05/20/2021

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (Verified At Inspection)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $500.00 $500.00 Paid 06/24/2021
8331507-Sewer Connection Fee $240.00 $240.00 Paid 06/24/2021
7232302-Commercial License Tax Fee $3,967.50 $3,967.50 Paid 08/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2021
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 6/29/2021 6/29/2021 06/29/2021
Underslab Electrical Inspection - Commercial Passed 6/30/2021 6/30/2021 06/30/2021
Misc
Informational
06/30/2021
UNDERSLAB CONDUIT FOR CABINETS
In-wall Inspection Partial 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/14/2021
- ELECTRIC APPROVED - FIRE CAULK GAS LINES AT TOP PLATE PENETRATION SCHEDULE PLUMBING & MECHANICAL INSPECTIONS BEFORE COVERING
In-wall Inspection Failed 7/15/2021 7/15/2021 07/15/2021
Misc
Corrective Action Required
07/14/2021
- ELECTRIC APPROVED - FIRE CAULK GAS LINES AT TOP PLATE PENETRATION Provide dryer vent Provide exhaust fan restroom Provide midpoint support DWV 2" & smaller Provide boca plates @ DWV restroom & dishwasher Support pex above water heater Provide grommets pex line penetrations at top plate
In-wall Inspection Not Ready 7/16/2021 7/16/2021 07/16/2021
Misc
Corrective Action Required
07/15/2021
- ELECTRIC APPROVED - Provide dryer vent Provide exhaust fan restroom Support pex above water heater
Above Ceiling Inspection Partial 7/20/2021 07/20/2021
Misc
Informational
07/20/2021
- HARD LID RESTROOM -
In-wall Inspection Partial 7/20/2021 7/20/2021 07/20/2021
Misc
Informational
07/20/2021
- ELECTRIC, PLUMBING, FRAMING, APPROVED
Occupancy Inspection - Codes Commercial Not Ready 8/16/2021 8/16/2021 08/16/2021
Miscellaneous Correction
Corrective Action Required
08/16/2021
License tax and fees have not been paid as of Friday, August 13
In-wall Inspection Passed 8/16/2021 08/16/2021
Misc
Informational
07/20/2021
- ELECTRIC, PLUMBING, FRAMING, APPROVED
Occupancy Inspection - Fire Not Ready 8/16/2021 8/16/2021 08/16/2021
Above Ceiling Inspection Passed 8/18/2021 08/18/2021
Misc
Informational
07/20/2021
- HARD LID RESTROOM -
Gas Piping Inspection - Commercial Passed 8/18/2021 08/18/2021
Gas Service Inspection - Commercial Passed 8/18/2021 08/18/2021
Occupancy Inspection - Codes Commercial Full C of O 8/18/2021 08/18/2021
Miscellaneous Correction
Corrective Action Required
08/16/2021
License tax and fees have not been paid as of Friday, August 13
Occupancy Inspection - Fire Passed 8/18/2021 08/18/2021
Resolved
08/18/2021
Informational
08/18/2021
Final was appropriate with no life safety violations noted.
Resolved
08/18/2021
Documents & Images
Date Uploaded File Type Document Name
05/20/2021 Application Form soap app
05/20/2021 Application Form soap LT
05/20/2021 Plans BCS Lees Summit, MO - Final S&S 4-5-21 (1)
05/20/2021 Letter Fire Building Plan Review
05/24/2021 Letter DS P/R Corrections Document
06/07/2021 Drawing P5 Gas Piping Plan
06/07/2021 Letter DS P_R Corrections Document
06/07/2021 Drawing A0.1 Projectr Information
06/07/2021 Drawing E3 Panel Schedule & Riser
06/07/2021 Drawing P4 Schedules, Notes & Details
06/07/2021 Letter Fire Building Plan Review
06/07/2021 Approved Plans approved - BCS Lees Summit, MO
06/07/2021 Letter License Tax Bill
06/24/2021 Receipt Receipt for transaction:2021-004917
06/25/2021 Letter DS Building Permit
06/29/2021 Letter INSPECTION SUMMARY
06/30/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
08/16/2021 Letter INSPECTION SUMMARY
08/16/2021 Receipt Receipt for transaction:2021-006567
08/16/2021 Receipt Receipt for transaction:2021-006569
08/17/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter Field Certificate of Occupancy
08/18/2021 Letter Codes Final Certificate of Occupancy
08/18/2021 Letter Fire Loss Reduction Form
08/18/2021 Letter Fire Loss Reduction Form
08/18/2021 Letter Fire Loss Reduction Form
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home