Summary
PRCOM20114952
Building Permit - Commercial
Final Completion
BARBIERI KARA ANN &
CHANGE OF TENANT
CONVERT PREVIOUS OFFICE SPACE INTO A SALON. ORIGINALLY A HOUSE
09/07/2011
12/27/2011
04/02/2012
08/20/2012
Locations
Contacts
HIRST & ASSOCIATES P.C., Address:621 NE WOODS CHAPEL RD , Phone:(816) 525-2100  
MAR ENTERPRISES INC, Address:24408 E US 50 HWY, Phone:(816) 524-2398  
KANE ELECTRIC, Address:11 NW 1771ST RD, Phone:(816) 720-3740  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CLASSIC PLUMBING INC, Address:PO BOX 460, Phone:(816) 779-6200  
BARBIERI KARA ANN &, Address:203 SW JEFFERSON ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 12/27/2011
Codes Admin
Fire Plan Review Approved 12/22/2011 12/22/2011
Brian Austerman
Address numbers required
Corrective Action Required
12/21/2011

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action required - To be verified on inspection.
Portable fire extinguishers - general
Corrective Action Required
12/21/2011

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Building Plan Review Approved 12/22/2011 12/21/2011
Mike Weisenborn
Business License
Corrective Action Required
12/21/2011

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances.
License Tax Codes Approved 10/12/2011 10/14/2011
Mike Weisenborn
NEED CONTRACTOR INFORMATION
Building Plan Review Approved 10/12/2011 10/07/2011
Mike Weisenborn
Bldg - Stairways - Handrails required
Resolved
10/07/2011

2006 IBC 1009.10 - Handrails. Stairways shall have handrails on each side and shall comply with Section 1012. Where glass is used to provide the handrail, the handrail shall also comply with Section 2047. Provide more information on the required handrails for the new stairs on the north side of the building. Include size of the handrails and extensions. Mike Weisenborn October 03, 2011 - Per Tracy Deister, a code modification request needs to be submitted if the requirements of this section are not to be met. Mike Weisenborn October 07, 2011 - CMR approved
Bldg - Stairways - Treads and risers
Resolved
10/07/2011

2006 IBC 1009.3 - Stair treads and risers. Stair riser heights shall be 7 inches maximum and 4 inches minimum. Stair tread depths shall be 11 inches minimum. The riser height shall be measured vertically between the leading edges of adjacent treads. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the treads leading edge. Winder treads shall have a minimum tread depth of 11 inches measured at a right angle to the treads leading edge at a point 12 inches from the side where the treads are narrower and a minimum tread depth of 10 inches. Action required - Provide additional information for the new stairs on the north side of the building. Mike Weisenborn October 03, 2011 - Per Tracy Deister, a code modification request needs to be submitted if the requirements of this section are not to be met. Mike Weisenborn October 07, 2011 - CMR approved
Misc
Resolved
10/07/2011

I am unable to locate vent information for the new shampoo bowls. Action required - Provide additional information. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Plumb - Backflow general 608.3
Resolved
10/07/2011

2006 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softeners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination. Action required - Show compliance for the shampoo bowls. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Mech - Outdoor air required
Resolved
10/07/2011

2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - The outside air calculation provided is not based on beauty shop. Make needed corrections. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Business License
Corrective Action Required
10/05/2011

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - The permit can not be approved until the names of the general, mechanical, electrical and plumbing contractors have been provided and their license verified.
Fire Plan Review Approved 10/12/2011 10/06/2011
Brian Austerman
Address numbers required
Corrective Action Required
10/06/2011

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Provide addressing and suite numbers on exterior doors
Portable fire extinguishers - general
Corrective Action Required
10/06/2011

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Internal Plan Review (Res) Rejected 10/04/2011 10/05/2011
Mike Weisenborn
Fire Plan Review Approved 10/04/2011 10/04/2011
Jim Eden
Building Plan Review Rejected 10/04/2011 10/03/2011
Mike Weisenborn
Bldg - Ramps - Edge protection
Resolved
10/03/2011

2006 IBC 1010.9 - Edge protection. Edge protection complying with Sections 1010.9.1 or 1010.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. Action required - Show how this requirement will be met. Mike Weisenborn October 03, 2011 - Notes have been added.
Misc
Resolved
10/03/2011

2006 IBC 10105.1 - Width. The minimum width of a means of egress ramp shall not be less than that required for corridors by Section 1017.2. The clear width of a ramp and clear width between handrails, if provided, shall be 36 inches minimum. Action required - Provide this minimum dimension on the plans. Mike Weisenborn October 03, 2011 - Added to Sheet A-2.
Bldg - Stairways - Handrails required
Corrective Action Required
09/28/2011

2006 IBC 1009.10 - Handrails. Stairways shall have handrails on each side and shall comply with Section 1012. Where glass is used to provide the handrail, the handrail shall also comply with Section 2047. Provide more information on the required handrails for the new stairs on the north side of the building. Include size of the handrails and extensions. Mike Weisenborn October 03, 2011 - Per Tracy Deister, a code modification request needs to be submitted if the requirements of this section are not to be met.
Bldg - Stairways - Treads and risers
Corrective Action Required
09/28/2011

2006 IBC 1009.3 - Stair treads and risers. Stair riser heights shall be 7 inches maximum and 4 inches minimum. Stair tread depths shall be 11 inches minimum. The riser height shall be measured vertically between the leading edges of adjacent treads. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the treads leading edge. Winder treads shall have a minimum tread depth of 11 inches measured at a right angle to the treads leading edge at a point 12 inches from the side where the treads are narrower and a minimum tread depth of 10 inches. Action required - Provide additional information for the new stairs on the north side of the building. Mike Weisenborn October 03, 2011 - Per Tracy Deister, a code modification request needs to be submitted if the requirements of this section are not to be met.
Accessibility - Water closet - Grab bars
Resolved
10/03/2011

ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - A code modifiaction request must be submitted and reviewed prior to allowance for the variance requested for the vertical grab bar.
Misc
Resolved
10/03/2011

The plans submitted for review do not include a nails area. The review performed is based on the assumption that nail work will not be done at this facility. If nail work is to be done than the stations need to be located on the plans and the required alterations to the space for outside air, exhaust and possible restrooms need to be made. Action required - This comment is for information purposes. Mike Weisenborn October 03, 2011 - Per the re-submittal letter, nails will not be done at this location.
Misc
Resolved
10/03/2011

The scale for the floor plan on Sheet A2 is incorrect. Action required - Make needed corrections.
Misc
Corrective Action Required
09/28/2011

I am unable to locate vent information for the new shampoo bowls. Action required - Provide additional information. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Plumb - Backflow general 608.3
Corrective Action Required
09/28/2011

2006 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softeners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination. Action required - Show compliance for the shampoo bowls. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Mech - Outdoor air required
Corrective Action Required
09/28/2011

2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - The outside air calculation provided is not based on beauty shop. Make needed corrections. Mike Weisenborn October 03, 2011 - The re-submittal letter references Sheet M-1 but we did not receive a revision on this sheet. Provide additional information.
Misc
Resolved
10/03/2011

The initial Total Building Area provided under the Building Data states 35,000 square feet. Action required - Make needed corrections.
Misc
Resolved
10/03/2011

When calculating occupant loads they are always rounded up. The occupant load calculations found in the Building Data are not. The occupant load for the first floor area would be 12 based on the formula shown but we do not calculate salons based on this formula. The occupant load of a salon is based on two people for each cutting station plus seating in the waiting area. Action required - Make needed corrections. If the occupant load of the 1st floor is greater than 15 separate restroom facilities are required. A second restroom can be added or a code modification request can be submitted.
Business License
Corrective Action Required
10/03/2011

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - The permit can not be approved until the names of the general, mechanical, electrical and plumbing contractors have been provided and their license verified.
Internal Plan Review (Res) Rejected 09/19/2011 09/19/2011
Mike Weisenborn
Building Plan Review Rejected 09/19/2011 09/19/2011
Mike Weisenborn
Bldg - Ramps - Edge protection
Corrective Action Required
09/19/2011

2006 IBC 1010.9 - Edge protection. Edge protection complying with Sections 1010.9.1 or 1010.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. Action required - Show how this requirement will be met.
Misc
Corrective Action Required
09/19/2011

2006 IBC 10105.1 - Width. The minimum width of a means of egress ramp shall not be less than that required for corridors by Section 1017.2. The clear width of a ramp and clear width between handrails, if provided, shall be 36 inches minimum. Action required - Provide this minimum dimension on the plans.
Bldg - Stairways - Handrails required
Corrective Action Required
09/19/2011

2006 IBC 1009.10 - Handrails. Stairways shall have handrails on each side and shall comply with Section 1012. Where glass is used to provide the handrail, the handrail shall also comply with Section 2047. Provide more information on the required handrails for the new stairs on the north side of the building. Include size of the handrails and extensions.
Bldg - Stairways - Treads and risers
Corrective Action Required
09/19/2011

2006 IBC 1009.3 - Stair treads and risers. Stair riser heights shall be 7 inches maximum and 4 inches minimum. Stair tread depths shall be 11 inches minimum. The riser height shall be measured vertically between the leading edges of adjacent treads. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the treads leading edge. Winder treads shall have a minimum tread depth of 11 inches measured at a right angle to the treads leading edge at a point 12 inches from the side where the treads are narrower and a minimum tread depth of 10 inches. Action required - Provide additional information for the new stairs on the north side of the building.
Accessibility - Water closet - Grab bars
Corrective Action Required
09/19/2011

ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - A code modifiaction request must be submitted and reviewed prior to allowance for the variance requested for the vertical grab bar.
Misc
Corrective Action Required
09/19/2011

The plans submitted for review do not include a nails area. The review performed is based on the assumption that nail work will not be done at this facility. If nail work is to be done than the stations need to be located on the plans and the required alterations to the space for outside air, exhaust and possible restrooms need to be made. Action required - This comment is for information purposes.
Misc
Corrective Action Required
09/19/2011

The scale for the floor plan on Sheet A2 is incorrect. Action required - Make needed corrections.
Misc
Corrective Action Required
09/19/2011

I am unable to locate vent information for the new shampoo bowls. Action required - Provide additional information.
Plumb - Backflow general 608.3
Corrective Action Required
09/19/2011

2006 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softeners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination. Action required - Show compliance for the shampoo bowls.
Mech - Outdoor air required
Corrective Action Required
09/19/2011

2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - The outside air calculation provided is not based on beauty shop. Make needed corrections.
Misc
Corrective Action Required
09/19/2011

The initial Total Building Area provided under the Building Data states 35,000 square feet. Action required - Make needed corrections.
Misc
Corrective Action Required
09/19/2011

When calculating occupant loads they are always rounded up. The occupant load calculations found in the Building Data are not. The occupant load for the first floor area would be 12 based on the formula shown but we do not calculate salons based on this formula. The occupant load of a salon is based on two people for each cutting station plus seating in the waiting area. Action required - Make needed corrections. If the occupant load of the 1st floor is greater than 15 separate restroom facilities are required. A second restroom can be added or a code modification request can be submitted.
Fire Plan Review Approved 09/19/2011 09/14/2011
Jim Eden
Address numbers required
Corrective Action Required
09/14/2011

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm).
Portable fire extinguishers - general
Corrective Action Required
09/14/2011

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum 2A:10B:C fire extinguishernear the stairs on the first floor. Verified at inspection.
Misc
Corrective Action Required
09/15/2011

Plans were not provided for the second floor. According to Mr Hirst the upstairs was to used for storage for now. Provide emergency lighting on the stairs. Verified at inspection.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $102.13 $102.13 Paid 12/27/2011
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 4/2/2012 (8:00 to 5:00) 04/02/2012
Misc
Corrective Action Required
04/02/2012
ELECTRIAL LUMINAIRES INSTALLED AT SHOWERS MUST BE LISTED FOR WET LOCATIONS -- PROVIDE DOCUMENTATION
Misc
Corrective Action Required
04/02/2012
CHECK WIRING OF ELECTRICAL SUB-PANEL PER NEC: BONDING JUMPER NOT REMOVED; 4-WIRE FEEDER REQUIRED; TERMINATIONS SUBJECT TO APPROVAL WHEN COMPLETED AND REQUESTED FOR INSPECTION
Misc
Corrective Action Required
04/02/2012
NEC 110 - 26 (a) (b); IRC 3305.1: DEDICATED WORKING/CLEAR SPACE AT ELECTRICAL SERVICE EQUIPMENT NOT WIDTH OF EQPMT OR 30" BY 36" DEEP
Misc
Corrective Action Required
04/02/2012
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL
Misc
Corrective Action Required
04/02/2012
NEC 330.30: NON-METALLIC ELECTRICAL BRANCH CIRCUIT CABLES NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO SUB-PANEL ENCLOSURE; ENSURE EACH ENTRY IS PROTECTED BY GROMMET
Misc
Corrective Action Required
04/02/2012
NEC 110-12: UNUSED OPENINGS AT ELECTRICAL PANELS / BOXES NOT PLUGGED. CHECK ALL.
Misc
Corrective Action Required
04/02/2012
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE; 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES
Misc
Corrective Action Required
04/02/2012
NEC 314.16; IRC E3905.13 ELECTRICAL BOX FILL: CHECK ALL ELECTRICAL BOXES FOR BOX FILL RESTRICTIONS -- CORRECT AS NEEDED
Misc
Corrective Action Required
04/02/2012
COMPLETE GLUING OF ALL PVC PLUMBING PIPING JOINTS AND SUPPORTING OF PIPING SUCH AS AT BASEMENT BELOW RESTROOM ABOVE
Misc
Corrective Action Required
04/02/2012
SECURE PEX WATER SERVICE PIPING TO WALL ABOVE PRESSURE REGULATOR
Misc
Corrective Action Required
04/02/2012
SECURE ELECTRICAL GROUNDING ELECTRODE CONDUCTOR CONDUIT TO WALL ABOVE CONNECTION TO WATER SERVICE PIPE
Misc
Corrective Action Required
04/02/2012
SECURE ALL (NEW AND EXISTING) NM AND BX ELECTRICAL CABLE TO JOISTS ABOVE OR OTHER STRUCTURE AT BASEMENT
Misc
Corrective Action Required
04/02/2012
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. CHECK ALL.
Misc
Corrective Action Required
04/02/2012
REPLACE OR REINFORCE STUDS, JOISTS, OR BEAMS CUT OR NOTCHED FOR INSTALLATION OF PLUMBING PIPING. EXAMPLE: FLOOR JOISTS OR BEAMS WITH DAMAGE VISIBLE AT BASEMENT
Final Inspection - Commercial Not Ready 4/2/2012 at 12:00 AM 04/02/2012
Misc
Corrective Action Required
04/02/2012
WATER HEATER REQUIRES EXPANSION TANK -- SEE INSTALLATION INSTRUCTIONS AND PLUMBING CODE
Misc
Corrective Action Required
04/02/2012
BACKFLOW PREVENTION REQUIRED AT HOSE BIBS AT BASEMENT
Misc
Corrective Action Required
04/02/2012
GUARDS AND HANDRAILS AT STAIRS TO BE MADE SUBSTANTIALLY CODE-COMPLIANT. INFORMATION TO BE PROVIDED AND DISCUSSIONS TO FOLLOW.
Final Inspection - Commercial Not Ready 4/24/2012 at 12:00 AM 04/24/2012
Misc
Resolved
04/24/2012
WATER HEATER REQUIRES EXPANSION TANK -- SEE INSTALLATION INSTRUCTIONS AND PLUMBING CODE
Misc
Resolved
04/24/2012
BACKFLOW PREVENTION REQUIRED AT HOSE BIBS AT BASEMENT
Misc
Resolved
04/24/2012
GUARDS AND HANDRAILS AT STAIRS TO BE MADE SUBSTANTIALLY CODE-COMPLIANT. INFORMATION TO BE PROVIDED AND DISCUSSIONS TO FOLLOW.
Misc
Resolved
05/04/2012
ALL EXPOSED ELEMENTS ARE SUBJECT TO APPROVAL AT FINAL INSPECTION FOR OCCUPANCY
All Rough Inspection - Commercial Failed 4/24/2012 at 12:00 AM 04/24/2012
Misc
Corrective Action Required
04/02/2012
ELECTRIAL LUMINAIRES INSTALLED AT SHOWERS MUST BE LISTED FOR WET LOCATIONS -- PROVIDE DOCUMENTATION
Misc
Resolved
04/24/2012
CHECK WIRING OF ELECTRICAL SUB-PANEL PER NEC: BONDING JUMPER NOT REMOVED; 4-WIRE FEEDER REQUIRED; TERMINATIONS SUBJECT TO APPROVAL WHEN COMPLETED AND REQUESTED FOR INSPECTION
Misc
Resolved
04/24/2012
NEC 110 - 26 (a) (b); IRC 3305.1: DEDICATED WORKING/CLEAR SPACE AT ELECTRICAL SERVICE EQUIPMENT NOT WIDTH OF EQPMT OR 30" BY 36" DEEP
Misc
Resolved
04/24/2012
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL
Misc
Corrective Action Required
04/02/2012
NEC 330.30: NON-METALLIC ELECTRICAL BRANCH CIRCUIT CABLES NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO SUB-PANEL ENCLOSURE; ENSURE EACH ENTRY IS PROTECTED BY GROMMET
Misc
Resolved
04/24/2012
NEC 110-12: UNUSED OPENINGS AT ELECTRICAL PANELS / BOXES NOT PLUGGED. CHECK ALL.
Misc
Corrective Action Required
04/02/2012
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE: SEE AT WOOD-FACED WALLS @ SE SPACE
Misc
Corrective Action Required
04/02/2012
NEC 314.16; IRC E3905.13 ELECTRICAL BOX FILL: CHECK ALL ELECTRICAL BOXES FOR BOX FILL RESTRICTIONS. SEE AT BASEMENT -- CORRECT AS NEEDED BEFORE FINAL INSPECTION
Misc
Resolved
04/24/2012
COMPLETE GLUING OF ALL PVC PLUMBING PIPING JOINTS AND SUPPORTING OF PIPING SUCH AS AT BASEMENT BELOW RESTROOM ABOVE
Misc
Resolved
04/24/2012
SECURE PEX WATER SERVICE PIPING TO WALL ABOVE PRESSURE REGULATOR
Misc
Resolved
04/24/2012
SECURE ELECTRICAL GROUNDING ELECTRODE CONDUCTOR CONDUIT TO WALL ABOVE CONNECTION TO WATER SERVICE PIPE
Misc
Corrective Action Required
04/02/2012
BEFORE FINAL INSPECTION SECURE ALL (NEW AND EXISTING) NM ELECTRICAL CABLE TO JOISTS ABOVE OR OTHER STRUCTURE AT BASEMENT
Misc
Corrective Action Required
04/02/2012
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD (BOCA) PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. CHECK ALL.
Misc
Corrective Action Required
04/24/2012
REINFORCE BORED & NOTCHED JOIST AT 1ST FLOOR RESTROOM TOP OF EAST WALL
Misc
Corrective Action Required
04/24/2012
IRC R502.13; R602.8: FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN PLATES, HOLES IN FLOOR
All Rough Inspection - Commercial Failed 4/30/2012 at 12:00 AM 04/30/2012
Misc
Resolved
04/30/2012
ELECTRIAL LUMINAIRES INSTALLED AT SHOWERS MUST BE LISTED FOR WET LOCATIONS -- PROVIDE DOCUMENTATION
Misc
Resolved
04/30/2012
NEC 330.30: NON-METALLIC ELECTRICAL BRANCH CIRCUIT CABLES NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO SUB-PANEL ENCLOSURE; ENSURE EACH ENTRY IS PROTECTED BY GROMMET
Misc
Corrective Action Required
04/24/2012
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE: SEE AT WOOD-FACED WALLS @ SE SPACE
Misc
Resolved
04/30/2012
NEC 314.16; IRC E3905.13 ELECTRICAL BOX FILL: CHECK ALL ELECTRICAL BOXES FOR BOX FILL RESTRICTIONS. SEE AT BASEMENT -- CORRECT AS NEEDED BEFORE FINAL INSPECTION
Misc
Resolved
04/30/2012
BEFORE FINAL INSPECTION SECURE ALL (NEW AND EXISTING) NM ELECTRICAL CABLE TO JOISTS ABOVE OR OTHER STRUCTURE AT BASEMENT
Misc
Corrective Action Required
04/24/2012
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD (BOCA) PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. CHECK ALL.
Misc
Resolved
04/30/2012
REINFORCE BORED & NOTCHED JOIST AT 1ST FLOOR RESTROOM TOP OF EAST WALL
Misc
Corrective Action Required
04/24/2012
IRC R502.13; R602.8: FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN PLATES, HOLES IN FLOOR
All Rough Inspection - Commercial Passed 5/4/2012 5/4/2012 at 12:00 AM 05/04/2012
Misc
Resolved
05/04/2012
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE: SEE AT WOOD-FACED WALLS @ SE SPACE
Misc
Resolved
05/04/2012
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD (BOCA) PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. CHECK ALL.
Misc
Resolved
05/04/2012
IRC R502.13; R602.8: FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN PLATES, HOLES IN FLOOR
Final Inspection - Commercial Failed 8/6/2012 at 12:00 AM 08/06/2012
Misc
Corrective Action Required
08/06/2012
RESOLVE ISSUES OF OTHER DEPARTMENTS: - WATER UTILITIES DEPARTMENT - FIRE DEPARTMENT - PLANNING & DEVELOPMENT DEPARTMENT
Misc
Corrective Action Required
08/06/2012
NEC 330.30: NON-METALLIC ELECTRICAL WHIP NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO A/C DISCONNECT ENCLOSURE.
Misc
Corrective Action Required
08/06/2012
TEST ALL ELECTRICAL RECEPTACLES. OPEN GROUNDS FOUND AT EXTERIOR RECEPT @ SW, 2ND FLOOR SW ROOM, BASEMENT CENTER & WEST CIRCUITS
Misc
Corrective Action Required
08/06/2012
WATER CLOSETS AT RESTROOM REQUIRE COMMERCIAL TYPE OPEN FRONT SEATS. ACCESSIBILITY REQUIRES FLUSH HANDLE ON FREE SIDE OF TANK. RECCOMMEND SEAL BASE TO FLOOR.
Misc
Corrective Action Required
08/06/2012
BOTTOM OF ACCESSIBLE RESTROOM MIRROR GLASS IS ABOVE 40" MAXIMUM FROM FLOOR.
Misc
Corrective Action Required
08/06/2012
WIRING CONNECTION FOR EXTERIOR LIGHTS MUST BE HARD-WIRED INSTEAD OF PLUG-IN AT 2ND FLOOR NW ROOM CLOSET
Misc
Corrective Action Required
08/06/2012
ELECT RECEPTS @ KIT SINK COUNTER NOT GFI-PROTECTED.
Misc
Corrective Action Required
08/06/2012
ELECT RECEPTS AT 1ST FLR RESTROOM NOT GFI PROTECTED
Misc
Corrective Action Required
08/06/2012
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE; SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE"
Misc
Corrective Action Required
08/06/2012
UNUSED OPENINGS AT MAIN ELECTRICAL PANEL NOT CLOSED -- USE LISTED PLUGS
Misc
Corrective Action Required
08/06/2012
BEAM SUPPORT POST AT BASEMENT CENTER NEEDS SPICE REINFORCED.
Misc
Corrective Action Required
08/06/2012
ENSURE A/C CONDENSER ELECTRICAL CIRCUIT IS NOT OVER-AMPED (40A MAX).
Occupancy Inspection - Fire Passed 8/6/2012 at 12:00 AM 08/06/2012
Misc
Corrective Action Required
08/06/2012
remove slide bolt lock from west exit
Final Inspection - Commercial Partial 8/13/2012 8/13/2012 at 12:00 AM 08/13/2012
Misc
Resolved
08/13/2012
RESOLVE ISSUES OF OTHER DEPARTMENTS: - WATER UTILITIES DEPARTMENT - FIRE DEPARTMENT - PLANNING & DEVELOPMENT DEPARTMENT
Misc
Resolved
08/13/2012
NEC 330.30: NON-METALLIC ELECTRICAL WHIP NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO A/C DISCONNECT ENCLOSURE.
Misc
Resolved
08/13/2012
TEST ALL ELECTRICAL RECEPTACLES. OPEN GROUNDS FOUND AT EXTERIOR RECEPT @ SW, 2ND FLOOR SW ROOM, BASEMENT CENTER & WEST CIRCUITS
Misc
Resolved
08/13/2012
WATER CLOSETS AT RESTROOM REQUIRE COMMERCIAL TYPE OPEN FRONT SEATS. ACCESSIBILITY REQUIRES FLUSH HANDLE ON FREE SIDE OF TANK. RECCOMMEND SEAL BASE TO FLOOR.
Misc
Resolved
08/13/2012
BOTTOM OF ACCESSIBLE RESTROOM MIRROR GLASS IS ABOVE 40" MAXIMUM FROM FLOOR.
Misc
Resolved
08/13/2012
WIRING CONNECTION FOR EXTERIOR LIGHTS MUST BE HARD-WIRED INSTEAD OF PLUG-IN AT 2ND FLOOR NW ROOM CLOSET
Misc
Corrective Action Required
08/06/2012
ELECT RECEPT @ NORTH END OF KIT COUNTER NOT GFI-PROTECTED.
Misc
Corrective Action Required
08/06/2012
ELECT RECEPT NEAR SINK AT 1ST FLR RESTROOM NOT GFI PROTECTED
Misc
Resolved
08/13/2012
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE; SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE"
Misc
Resolved
08/13/2012
UNUSED OPENINGS AT MAIN ELECTRICAL PANEL NOT CLOSED -- USE LISTED PLUGS
Misc
Resolved
08/13/2012
BEAM SUPPORT POST AT BASEMENT CENTER NEEDS SPLICE REINFORCED.
Misc
Resolved
08/13/2012
ENSURE A/C CONDENSER ELECTRICAL CIRCUIT IS NOT OVER-AMPED (40A MAX).
Misc
Corrective Action Required
08/13/2012
ELECT RECEPT @ EXTERIOR WALL WEST NOT GFI-PROTECTED. IN-USE COVER REQUIRED FOR WET LOCATION.
Final Inspection - Commercial Partial 8/15/2012 at 12:00 AM 08/15/2012
Misc
Resolved
08/15/2012
ELECT RECEPT @ NORTH END OF KIT COUNTER NOT GFI-PROTECTED.
Misc
Resolved
08/15/2012
ELECT RECEPT NEAR SINK AT 1ST FLR RESTROOM NOT GFI PROTECTED
Misc
Resolved
08/15/2012
ELECT RECEPT @ EXTERIOR WALL WEST NOT GFI-PROTECTED. IN-USE COVER REQUIRED FOR WET LOCATION.
Misc
Corrective Action Required
08/15/2012
OBTAIN FINAL APPROVAL OF WATER DEPARTMENT
Final Inspection - Commercial Passed 8/17/2012 at 12:00 AM 08/17/2012
Misc
Resolved
08/17/2012
OBTAIN FINAL APPROVAL OF WATER DEPARTMENT
Documents & Images
Date Uploaded File Type Document Name
09/19/2011 Letter Plan Review Conditions
10/05/2011 Letter Plan Review Conditions
12/27/2011 Letter Building Permit
12/27/2011 Letter Plan Review Conditions
12/27/2011 Letter 20111227160405592.pdf
04/02/2012 Letter Inspection Summary
04/24/2012 Letter Inspection Summary
04/30/2012 Letter Inspection Summary
05/04/2012 Letter Inspection Summary
08/06/2012 Letter Inspection Summary
08/06/2012 Letter Fire Loss Reduction Form
08/13/2012 Letter Inspection Summary
08/15/2012 Letter Inspection Summary
08/17/2012 Letter Inspection Summary
06/25/2013 Letter Fire Building Plan Review
06/27/2013 Letter Fire Building Plan Review
06/27/2013 Letter Fire Loss Reduction Form
06/27/2013 Letter Fire Building Plan Review
06/27/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home