Planning Application Status

PL2025189




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2025189
Sequoia Residential Lots 4-5 and Tract 1B
Minor Plat
Minor Plat
In Plan Review
07/18/2025
A Replat of Sequoia Residential
Locations
Contacts
Sean A Siebert, Address:1813 SW Fountain Drive, Phone:(816) 365-3848  
Sean Siebert, Address:1813 SW Fountain Drive  
BOUNDARY AND CONSTRUCTION SURVEYING, Address:821 NE COLUMBUS ST., SUITE 100, Phone:(816) 554-9798  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review Corrections 08/11/2025 08/11/2025
Adair Bright
Corrective Action Required
08/11/2025

Renumber the lots to be 7-10. This will provide clarity in the future and allow for amendments to those lots if needed.
Corrective Action Required
08/11/2025

Rename the Tract to "Tract A1"
Corrective Action Required
08/11/2025

Update the plat title, dedication, "square footage" table, and common area language to reflect the updated lots and tract names.
Corrective Action Required
08/11/2025

Remove the building setback dimensions and building separation dimensions.
Corrective Action Required
08/11/2025

Remove the 20' dashed setback line shown around the detention area.
Corrective Action Required
08/11/2025

Update the signature block - "Tracy L. Albers, Director of Development Services."
Corrective Action Required
08/11/2025

Are the driveways really intended to be covered with access easements instead of being included in the lots? This would allow for everyone within the subdivision to have the right to park on a driveway whether or not it relates to their unit. If that is the intent, provide access easement language.
Corrective Action Required
08/11/2025

Update Lots 1-6 to reflect the comments made on PL2025188.
Engineering Review Corrections 08/11/2025 08/11/2025
Gene Williams, P.E.
Corrective Action Required
08/11/2025

Easement dedication language does not match what is shown on the plat. U/e is shown on the plat, but the dedication language calls-out U.E. Therefore, change the plat to match what is shown on the dedication language and vice versa.
Traffic Review No Comments 08/11/2025 08/06/2025
Erin Ralovo
Fire Review No Comments 08/11/2025 08/06/2025
Jim Eden
GIS Plat Review Corrections 08/11/2025 07/30/2025
Kathy Kraemer
Corrective Action Required
07/30/2025

Please provide a dimension between the lot 3B and 4A along the ROW. I see 25.69 between 4B and 5A but no dimension on 3B/4A
Fees
Paid Fees Amount Paid Owing Date Paid
None $0.00 $0.00 $0.00
Outstanding Fees Amount Paid Owing Date Paid
Minor Plat fee $725.00 $0.00 $725.00 Not Paid


$725.00    Add Fees to My Cart
Hearings
Title Location Date Time
Documents & Images
Date Uploaded File Type Document Name
07/18/2025 Plans Minor Plat_Rev 0_PL2025189
07/28/2025 Application Form Minor Plat Application_PL2025189
08/11/2025 Letter Applicant Letter - MP (DRCL)
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home