Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review Approved with Conditions 08/17/2021 08/31/2021
Sue Pyles, P.E.
DE C&O #01 Eng Plans – FP/PP
Corrective Action Required
08/31/2021

All required engineering plans and studies, including water lines, sanitary sewers, storm drainage, streets and erosion and sediment control shall be submitted along with the final plat and approved prior to the approval of the final plat. All public infrastructure must be substantially complete, prior to the issuance of any building permits.
Fire Review No Comments 08/17/2021 08/17/2021
Mike Weisenborn
Planning Review Corrections 08/17/2021 08/17/2021
Shannon McGuire
Corrective Action Required
08/17/2021

To help make the document less cluttered, please reduce the topography contour lines to 10’ intervals.
Corrective Action Required
08/17/2021

Please add a note to the plat document that no gas wells are present and include the source of your information.
Corrective Action Required
08/17/2021

Please show the existing ROW for Main Street and label the portion to be vacated.
Traffic Review Corrections 08/17/2021 08/17/2021
Brad Cooley, P.E., RSPI
Corrective Action Required
08/17/2021

Sidewalk needs to be shown on the plat, to the extent of the plat boundary.
Engineering Review Corrections 07/23/2021 07/23/2021
Sue Pyles, P.E.
Corrective Action Required
07/23/2021

Please revise the Water Utilities contact information on the Cover Sheetto 816-969-1900 with no specific contact name or email. If you’d like to include the address, it is 1200 SE Hamblen Road, Lee’s Summit, MO 64081.
Corrective Action Required
07/23/2021

Please delete Sheet C101. It is not required at this time. Please review all notes on future submittals to ensure the correct city, state, departments, requirements, etc. are being referenced.
Corrective Action Required
07/23/2021

Please note that building footprints and parking lot layouts are not required on subsequent submittals.
Corrective Action Required
07/23/2021

Please provide a sanitary sewer analysis too determine downstream capacity of the existing sanitary sewer system. Please note that you'll want to estimate the most intensive sanitary use for the study.
Traffic Review Corrections 07/23/2021 07/22/2021
Brad Cooley, P.E., RSPI
Corrective Action Required
07/22/2021

Sheet L100 - Confirm sight distance is adequate on landscaping plan.
Corrective Action Required
07/22/2021

Sheet C200 - Main Street will extend past Sloan to Tudor. Change street name appropriately.
Corrective Action Required
07/22/2021

Sheet C200 - Existing Main St. needs to be removed at Tudor with curb, gutter and sidewalk replaced.
Corrective Action Required
07/22/2021

Sheet C200 - Median along Tudor needs to be constructed at Main St. break.
Corrective Action Required
07/22/2021

C200 - Clarify what the overlapping lines at the new intersection of Main and Sloan are.
Corrective Action Required
07/22/2021

Include typical section, and plan/profile for relocated Main Street.
Corrective Action Required
07/22/2021

Provide plan for signs/pavement markings and a plan for temporary traffic control.
Corrective Action Required
07/22/2021

Corrective Action Required
07/22/2021

Fire Review No Comments 07/23/2021 07/19/2021
Jim Eden
Planning Review Corrections 07/23/2021 07/15/2021
Shannon McGuire
Corrective Action Required
07/15/2021

Please note that when FDP’s and Final Plats are applied for, the plan size maximum will be 24” x 36” with 1” border. For the Preliminary Plat the 42” x 30” plan sheets are fine.
Corrective Action Required
07/15/2021

Please show the location of all oil and gas wells, whether active, inactive, or capped. If none are present please add note indicating so and cite your source of information.
Corrective Action Required
07/15/2021

Please take note, any existing easements that are recorded and/or platted but not needed and public roadways that conflict with the proposed plat must be vacated prior to final plat approval.
Corrective Action Required
07/15/2021

Please remove all references to proposed buildings, parking lots, and driveways. Please remove all landscaping and elevation sheets from the plan set. This information is not needed at this point in the project.
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Preliminary Plat fee $859.00 $859.00 Paid 07/09/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Planning Commission Meeting 09/09/2021 05:00 PM Council Chambers 09/09/2021 05:00 PM
Public Hearing Review
Complete
09/09/2021
Documents & Images
Date Uploaded File Type Document Name
07/07/2021 Application Form Signed Ownership Affidavit
07/07/2021 Plans V_PP_2104157 - Preliminary Plat Property Description - 2021.06.28
07/08/2021 Application Form Signed Preliminary Plat Application
07/08/2021 Application Form Preliminary Plat Checklist
07/08/2021 Engineer Report/Study Northeast Douglas Street & Northeast Skyline Drive_20210609144024
07/08/2021 Engineer Report/Study Tudor and Douglas_20210609144329
07/08/2021 Engineer Report/Study Tudor and Main_20210609145338
07/08/2021 Engineer Report/Study Tudor and Sloan_20210609144814
07/08/2021 Engineer Report/Study Tudor and Ward_20210609145448
07/08/2021 Engineer Report/Study Scannell TIS_Final
07/08/2021 Plans LEGAL DESCRIPTION-Preliminary Plat_2021_07_08
07/08/2021 Plans A200-ExteriorElevations-A200-24x36
07/08/2021 Plans A201-ExteriorElevations-A201-24x36
07/08/2021 Plans Mando_A200-ExteriorElevations-A200-24x36
07/08/2021 Plans Mando_A201-ExteriorElevations-A201-24x36
07/08/2021 Engineer Report/Study 2021-07-08_Preliminary Flood Study
07/08/2021 Engineer Report/Study 2021-07-08_Preliminary Stormwater Drainage Study
07/08/2021 Plans Preliminary Plat Plans
07/09/2021 Receipt Receipt for transaction: 2021-005506
07/09/2021 Application Form Signed Ownership Affidavit
07/23/2021 Letter Applicant Letter - PP (PP)
08/10/2021 Letter 2021_08_10_PP-General Engineering_Comment Response Letter
08/10/2021 Plans 2021_08_10_Preliminary Plat
08/10/2021 Engineer Report/Study 2021_08_10_Sanitary Sewer Memo
08/10/2021 Plans LEGAL DESCRIPTION-Preliminary Plat_2021_07_08
08/10/2021 Engineer Report/Study 2021_07_08_Scannell TIS_Final
08/10/2021 Engineer Report/Study 2021-07-08_Preliminary Stormwater Drainage Study
08/10/2021 Plans 2021_08_10_Preliminary Engineering Plans
08/10/2021 Engineer Report/Study 2021-07-08_Preliminary Flood Study
08/17/2021 Letter Applicant Letter - PP (PP)
08/27/2021 Letter 2021_08_27_PP-General Engineering_Comment Response Letter
08/27/2021 Plans 2021_08_27_Preliminary Plat
09/02/2021 Engineer Report/Study PL2021255 Lee's Summit Logistics TIA
09/02/2021 Engineer Report/Study Scannell TIS - Summary
09/07/2021 Letter PL2021-255 PP Lee's Summit Logistics PC
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home