Planning Application Status

PL2020040




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2020040
WOODLAND GLEN 2ND PLAT(SANITARY SEWER MAIN EXTENSION)
Engineering Plan Review
Engineering Plan Review
Approved
02/21/2020
ABP FUNDING LLC
Locations
Contacts
ABP FUNDING LLC, Address:11040 OAKMONT ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Record Drawings Review No Comments 10/31/2022 10/31/2022
Sue Pyles, P.E.
Record Drawings Review Corrections 10/17/2022 10/17/2022
Sue Pyles, P.E.
Engineering Review No Comments 06/04/2020 06/03/2020
Sue Pyles, P.E.
DE Contact Field Eng. Inspector
Corrective Action Required
06/01/2020

Contact the Field Engineering Inspector at (816) 969-1200 at least 48 hours prior to the onset of construction.
DE Engineers Estimate
Corrective Action Required
06/01/2020

The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee of $7,049.45 (which is based on 3% of the total infrastructure cost) must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit.
DE Future Repair Work
Corrective Action Required
06/01/2020

Please be aware that any future repair work to public infrastructure (e.g., water main repair, sanitary sewer repair, storm sewer repair, etc.) within public easements will not necessarily include the repair of pavement, curbing, landscaping, or other private improvements which are located within the easement.
Engineering Review Corrections 05/13/2020 05/13/2020
Sue Pyles, P.E.
Corrective Action Required
05/13/2020

Please review the easement widths to ensure you meet the minimum requirements of the Design and Construction Manual Section 6501.L.1.c. It would appear that Line B does not meet this requirement. Please review all widths and revise as needed. All revisions will need to be included on the Final Plat, as well as all other engineering plans.
Corrective Action Required
05/13/2020

Although not required, consider extending the sewer stub lengths for Lots 56-58 to extend all the way through the easement.
Corrective Action Required
05/13/2020

Please review the estimate quantity for Item 5, 6" PVC, it doesn't appear to match the plans. Revise the estimate as needed, and reflect any changes on the Summary of Quantities Table on Sheet 1. Make sure to resubmit a signed/sealed estimate.
Engineering Review Corrections 03/06/2020 03/06/2020
Sue Pyles, P.E.
Corrective Action Required
03/06/2020

Public infrastructure plans must match the associated plats for location of improvements. When resubmitting, please provide separate plan sets for Woodland Glen 2nd Plat and Woodland Glen 3rd Plat.
Corrective Action Required
03/06/2020

Sheet 1: • Please add the plat number to the project title on this sheet and the title block on all sheets. • Please revise the phone number to 816-969-1200 in General Note 13. • Please remove General Notes 13 & 14, they are not applicable. • Please remove the sanitary sewer portion of Utility Note 4, it is not allowed by MDNR. • Please include a Vicinity Map with nearby streets labeled.
Corrective Action Required
03/06/2020

Sheet 2: City records indicate the water main continues east from SW Winthrop Terrace on the north side of SW Heartwood Drive. Please show this main throughout the plan set.
Corrective Action Required
03/06/2020

Sheet 4: Design and Construction Manual Section 6501.D.g requires a minimum 0.5’ drop between the upstream and downstream sewer pipe inverts. Line A at MH A1 & Ex MH 3-B don’t meet this requirement. Please revise.
Corrective Action Required
03/06/2020

Sheet 5: • Include a note stating Doghouse MH for MH B! is not allowed. • Design and Construction Manual Section 6501.D.g requires a minimum 0.5’ drop between the upstream and downstream sewer pipe inverts. Line B at MH B2 doesn’t meet this requirement. Please revise.
Corrective Action Required
03/06/2020

Sheet 6: Design and Construction Manual Section 6501.D.g requires a minimum 0.5’ drop between the upstream and downstream sewer pipe inverts. Line C at MH B2 doesn’t meet this requirement. Please revise.
Corrective Action Required
03/06/2020

Sheets 7 & 8: Please remove all standard details not required for this project.
Corrective Action Required
03/06/2020

General: • Submit an Engineer's Estimate of Probable Construction Costs. • Submit the SWPPP and a copy of the MDNR Land Disturbance Permit.
Hearings
Title Location Date Time
Documents & Images
Date Uploaded File Type Document Name
02/21/2020 Letter Routing Sheet
03/06/2020 Letter DE-Comment Letter (Engineering Plans)
05/05/2020 Plans 18-017 SAN (REV1)
05/06/2020 Engineer Report/Study RESPONSE TO DE-Comment Letter 2nd-Sanitary(Engineering Plans) dated 05-06-2020
05/06/2020 Engineer Report/Study MDNR PERMIT.pdf
05/06/2020 Engineer Report/Study SWP2
05/06/2020 Engineers Estimate 18-017_Sanitary Public Engineers Probable Cost Estimate to City_RPM
05/11/2020 Plans 20200220_18-017 SAN (REV0)
05/13/2020 Letter DE-Comment Letter (Engineering Plans)
05/26/2020 Letter RESPONSE TO DE-Comment Letter 2nd-Sanitary(Engineering Plans) 5-21-2020
05/26/2020 Engineers Estimate 18-017_Sanitary Public Engineers Probable Cost Estimate to City_RPM 5-21-2020
05/26/2020 Plans 18-017 SAN (REV2)
06/01/2020 Activity Document Fees PL2020040 Woodland Glen 2nd Plat Public Sanitary
07/15/2020 Letter WoodlandGlen2ndplat_MO0101087_202000701_MOGSE0035_CP
07/15/2020 Activity Document PL2020040 Woodland Glen 2nd Plat MDNR Conc. Letter SAT Elec Signed
07/20/2020 Email PL2020040 Woodland Glen 2nd Plat Sanitary Pending Items
05/27/2021 Plans Woodland Glen 2nd Plat - Barbour - Sanitary Submittal RPM
06/01/2021 Plans 20210601_18-017 SS ESC SET (Rev_3)
06/04/2021 Plans 20210603_18-017 SANITARY SET (Rev_ 5)
06/07/2021 Approved Plans Woodland Glen, 2nd Plat - Sanitary Sewer extention Approved 6.7.21
06/08/2021 Letter DE-Engineering Plans Approval Letter
12/01/2021 Plans Full Set Line D Revision
12/01/2021 Plans Pages from Woodland Glen, 2nd Plat - Sanitary Sewer extention Approved 6.7.21 CORRECTED MH SLOPES LINE B (1)
10/05/2022 Plans 20220926_18-017 SANIATARY AS-BUILTS
10/17/2022 Email Woodland Glen 2nd Plat Sanitary Sewer and Water Record Drawing Review Comments
10/19/2022 Plans 20221018_18-017 SANIATARY AS-BUILTS-Rev_1
10/21/2022 Email Woodland Glen 2nd Plat Sanitary Sewer and Water Record Drawing Review Comments
10/21/2022 Plans 20221021_18-017 SANIATARY AS-BUILTS-Rev_1
11/14/2022 Plans 20221021_18-017 SANIATARY AS-BUILTS-Rev_1
12/01/2022 Accepted Record Drawings Woodland Glen 2nd Sanitary AsBuilts Accepted RD
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home