Permit Application Status

PRRES20116155


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20116155
Building Permit - Residential
Certificate of Occupancy
WOODLAND SHORES REAL ESTATE INC
NEW SINGLE FAMILY
HOUSE AND DECK
11/28/2011
12/09/2011
10/12/2012
Locations
Contacts
RIFFE HOMES INC, Address:1800 NE BLUE HERON DR, Phone:(816) 537-7000  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
SUBURBAN PLUMBING, Address:20124 HOPS CREEK DR, Phone:(816) 985-0259  
WOODLAND SHORES REAL ESTATE INC, Address:450 WINNEBAGO DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 12/06/2011
Codes Admin
True
Residential Plan Review Approved 11/30/2011 12/06/2011
Codes Admin
Plot Plan Review (P&D) Approved 11/30/2011 11/29/2011
Hector Soto Jr.
Plot Plan Review Approved 11/29/2011
Gene Williams, P.E.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,174.73 $1,174.73 Paid 12/09/2011
8331507-Sewer Connection Fee $570.00 $570.00 Paid 12/09/2011
Right of Way Permit Fee $60.00 $60.00 Paid 12/09/2011
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/9/2011 at 12:00 AM 12/09/2011
Underslab Plumbing Inspection - Residential Not Ready 1/18/2012 at 12:00 AM 01/18/2012
Sewer Service Inspection - R Passed 1/19/2012 at 12:00 AM 01/19/2012
Water Service Inspection - R Partial 1/19/2012 at 12:00 AM 01/19/2012
Erosion Control Inspection Residential Failed 1/19/2012 at 12:00 AM 01/19/2012
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/19/2012
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. EROSION CONTROL SHALL BE INSTALLED ALONG PROPERTY LINE WITH NEIGHBOR AND ALONG THE BACK PROPERTY LINE
Underslab Plumbing Inspection - Residential Passed 1/19/2012 at 12:00 AM 01/19/2012
All Rough Inspection - Residential Not Ready 5/15/2012 (8:00 to 5:00) 5/15/2012 at 12:00 AM 05/15/2012
Misc
Corrective Action Required
05/15/2012
NOT READY FOR INSPECTION *HAVE THE APPROVED PLAN ON SITE FOR INSPECTION *I SEE TOO MANY FRAMING DEFICIENCIES. HAVE THE STRUCTURAL ENGINEER GO THROUGH THE HOUSE TO CORRECT THINGS THAT NEED TO BE CORRECTED.
Gas Service Inspection - Residential Passed 5/15/2012 at 12:00 AM 05/15/2012
Electrical Service Inspection Failed 12/9/2011 at 12:00 AM 05/15/2012
Misc
Corrective Action Required
05/15/2012
PROVIDE LISTING OF THE GROUNDING CLAMP TO REBAR.
All Rough Inspection - Residential Not Ready 5/25/2012 (8:00 to 5:00) 5/25/2012 at 12:00 AM 05/25/2012
Misc
Corrective Action Required
05/15/2012
NOT READY FOR INSPECTION *STILL TOO MANY STRUCTURAL DEFICIENCIES. I SEE TOO MANY FRAMING DEFICIENCIES. HAVE THE STRUCTURAL ENGINEER GO THROUGH THE HOUSE TO CORRECT THINGS THAT NEED TO BE CORRECTED. INSPECTION TERMINATED. THINGS TO NOTE SO FAR: NAILING PATTERN OR 1000 LB STRAP AT GARAGE PORTAL WALL. TOE NAILING ALL JOISTS INTO PLATES NAILING OF 2ND FLOOR JOISTS TO LVL AT CURVED PORTION AT REAR OF THE HOUSE. AS IS, THERE IS NO WITHDRAW RESISTENCE. FULL BEARING FOR RED IRON I BEAM SUPPORTING SECOND FLOOR AT GARAGE ENTRY AND AT OPPOSITE SIDE BY STAIRS. VENT KITCHEN SINK ALL PLUMBING DWV DRILLED THROUGH STUDS REQUIRE STUD SHOES. LVL OVER FRONT DOOR NOT FASTENED TOGETHER PROPERLY.
Electrical Service Inspection Failed 5/29/2012 at 12:00 AM 05/29/2012
Misc
Corrective Action Required
05/15/2012
-REVERSE THE BOTTOM CLAMP WHEN CONNECT TO REBAR PER ILSCO INSTRUCTION; OR USE GREAVES JONES BOND REBAR CLAMP WHICH REQUIRES LESS SPACE AROUND REBAR
All Rough Inspection - Residential Failed 5/29/2012 at 12:00 AM 05/29/2012
Misc
Corrective Action Required
05/25/2012
FRAMING: -HAVE ENGINEER ADDRESS GARAGE PROTAL BRACE WALL. WALL COVERED -HAVE ENGINEER ADDRESS BASEMENT WINDOW HEADERS SUPPORT AT CURVED WALL -ANCHOR GARAGE AND BASEMENT SILL PLATE PER CODE: WITHIN 12" OF SILL BREAK AND MINIMUM 2 ANCHORS PER PLATE -NAIL CORNER STUDS PER CODE: 16D NAIL EVERY 12" OC (OR EQUIVALENT NAILING) -FIREBLOCKING: FB GARAGE CHASE FROM I BEAM FURDOWN, FROM JOIST SPACE, AND FROM KITCHEN SOFFIT. USE PROPER MATERIAL. 1/2" SHEATHING IS NO GOOD. USE 3/4" SHEATHING; FB WALL FROM SOFFIT AROUND IRON WASTE STACK. USE INSULATION; FB 2ND FL FIREPLACE SPACE FROM ATTIC -INSTALL JOIST HANGERS TO I BEAM CONNECTION ABOVE MUD RM -PROVIDE JOISTS LAYOUT PER PLAN ABOVE KITCHEN AREA-DOUBLE EVERY OTHER JOIST AND 3X 2X10 JOISTS -BRACE ALL INTERIOR WALLS PER PLAN -PROVIDE STEEL COLUMNS IN GARAGE PER PLAN OR HAVE ENGINEER OK -TOE-NAIL ALL JOISTS TO WALL TOP PLATES -LAG REAR WALL METAL FRAME TO LVLs AND FLOOR -VERIFY THAT THE REAR WINDOWS GLAZING AT REAR CURVED WALL ARE TEMPERED GLAZING -SUPPORT STAIR LANDING WHERE 5 2X6 ARE NAILED TOGETHER. LAG-SCREW THESE TOGETHER -PROVIDE FULL BEARING UNDER 2X JOISTS AT 1ST FL BED/BATH WALL -SUPPORT ALL HIP RAFTERS AT RIDGE ABOVE 2ND FL; SUPPORT UNDER CORNER CANTILEVERED LVL HIP AT MASTER CLOSET -INSTALL HEADER ABOVE FIRPLACE FIRESTOP ASSY MECHANICAL: -PROVIDE MINIMUM 1" CLEARANCE FROM B-VENT TO COMBUSTIBLE -PAN OFF RETURN AIR AT SHOWER SPACE -FRONT BATH RM NEAR STAIR PLUMBING: -VENT CONNECTIONS OPPOSITE OF DRAINAGE FLOW DIRECTION ABOVE GARAGE I BEAM AND ABOVE 1ST FL BATH -SHALL USE PROPER STIRKE PLATES FOR WARDFLEX PROTECTION. SEE MANUAL -STRAP TOP PLATE BORED MORE THAN 50% AT MASTER BATH ELECTRICAL: -PROTECT WIRING ACROSS CEILING JOISTS WITHIN 6 FT OF ATTIC ACCESS *DO NOT INSULATE NOR ROCK
All Rough Inspection - Residential Failed 6/4/2012 (8:00 to 5:00) 6/4/2012 at 12:00 AM 06/04/2012
Misc
Corrective Action Required
05/29/2012
FRAMING: -HAVE ENGINEER ADDRESS GARAGE PROTAL BRACE WALL. WALL COVERED -ANCHOR BASEMENT SILL PLATE PER CODE: WITHIN 12" OF SILL BREAK AND MINIMUM 2 ANCHORS PER PLATE -NAIL CORNER STUDS PER CODE: 16D NAIL EVERY 12" OC (OR EQUIVALENT NAILING) -FIREBLOCKING: FB GARAGE CHASE FROM I BEAM FURDOWN, FROM JOIST SPACE, AND FROM KITCHEN SOFFIT. USE PROPER MATERIAL. 1/2" SHEATHING IS NO GOOD. USE 3/4" SHEATHING; FB WALL FROM SOFFIT AROUND IRON WASTE STACK. USE INSULATION; FB 2ND FL FIREPLACE SPACE FROM ATTIC -PROVIDE JOISTS LAYOUT PER PLAN ABOVE KITCHEN AREA-DOUBLE EVERY OTHER JOIST AND 3X 2X10 JOISTS -BRACE ALL INTERIOR WALLS PER PLAN -TOE-NAIL ALL JOISTS TO WALL TOP PLATES -VERIFY THAT THE REAR WINDOWS GLAZING AT REAR CURVED WALL ARE TEMPERED GLAZING -PROVIDE FULL BEARING UNDER 2X JOISTS AT 1ST FL BED/BATH WALL CAN NOT VERIFY SOME THINGS DUE TO NOT HAVING PLANS ON SITE PLUMBING: -VENT CONNECTIONS OPPOSITE OF DRAINAGE FLOW DIRECTION ABOVE GARAGE I BEAM AND ABOVE 1ST FL BATH ELECTRICAL: -PROTECT WIRING ACROSS CEILING JOISTS WITHIN 6 FT OF ATTIC ACCESS *DO NOT INSULATE NOR ROCK
Water Service Inspection - R Passed 06/05/2012
All Rough Inspection - Residential Failed 6/5/2012 at 12:00 AM 06/05/2012
Misc
Corrective Action Required
06/04/2012
FRAMING: -NAIL SHEATHING -INTERIOR SIDE OF GARAGE PROTAL BRACE WALL PER ENGINEER LETTER -FIREBLOCKING: FB GARAGE CHASE FROM I BEAM FURDOWN, FROM JOIST SPACE, AND FROM KITCHEN SOFFIT. USE PROPER MATERIAL. 1/2" SHEATHING IS NO GOOD. USE 3/4" SHEATHING; FB 2ND FL FIREPLACE SPACE FROM ATTIC-FIREBLOCK PENETRATIONS OF FIRESTOP *OK TO INSULATE. NO ROCK
Electrical Service Inspection Passed 6/5/2012 at 12:00 AM 06/05/2012
Misc
Resolved
06/05/2012
-REVERSE THE BOTTOM CLAMP WHEN CONNECT TO REBAR PER ILSCO INSTRUCTION; OR USE GREAVES JONES BOND REBAR CLAMP WHICH REQUIRES LESS SPACE AROUND REBAR
Erosion Control Inspection Residential Passed 06/05/2012
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/05/2012
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. EROSION CONTROL SHALL BE INSTALLED ALONG PROPERTY LINE WITH NEIGHBOR AND ALONG THE BACK PROPERTY LINE
All Rough Inspection - Residential Passed 6/5/2012 at 12:00 AM 06/05/2012
Misc
Resolved
06/05/2012
FRAMING: -NAIL SHEATHING -INTERIOR SIDE OF GARAGE PROTAL BRACE WALL PER ENGINEER LETTER -FIREBLOCKING: FB GARAGE CHASE FROM I BEAM FURDOWN, FROM JOIST SPACE, AND FROM KITCHEN SOFFIT. USE PROPER MATERIAL. 1/2" SHEATHING IS NO GOOD. USE 3/4" SHEATHING; FB 2ND FL FIREPLACE SPACE FROM ATTIC-FIREBLOCK PENETRATIONS OF FIRESTOP *OK TO INSULATE. NO ROCK
Driveway Inspection Passed 7/27/2012 at 11:00 AM 07/30/2012
Occupancy Inspection - Codes Residential Failed 9/6/2012 9/6/2012 at 12:00 AM 09/06/2012
Misc
Corrective Action Required
09/06/2012
-OBTAIN LAWN SPRINKLER PERMIT -FINAL GRADE, SOD, SPLASHBLOCKS -ADDRESS -SEAL EXTERIOR WALL PENETRATIONS -SECURE GROUNDING ELECTRODE CONDUCTOR (TO ROD) TO WALL -INSTALL GRASPABLE HANDRAIL FOR DECK STAIR -REMOVE INSULATION FACING IN BASEMENT -INSTALL SECONDARY LOCKING DEVICES FOR BASEMENT SLIDE DOORS-PIN ASSY OR BOTTOM-MOUNTED BOLT ASSY -INSTALL LOCK DEVICE FOR HOOD BREAKER -INSTALL STRIKE PLATE WITH 4 OFFSET HOLES AND 3-3" SCREWS INTO STUDS AT FRONT DOOR -STAIR GUARDRAIL -PROVIDE ACCESS TO HYDROTUB MOTOR AND RECEPTACLE. I MIGHT BREAK THE PANEL IF I OPEN IT -INSTALL WATER ANTI-HAMMERING ARRESTORS FOR ALL QUICK CLOSING VALVES
Occupancy Inspection - Codes Residential Temporary C of O 9/12/2012 at 12:00 AM 09/12/2012
Misc
Corrective Action Required
09/06/2012
-OBTAIN LAWN SPRINKLER PERMIT -FINAL GRADE, SOD, SPLASHBLOCKS -INSTALL SECONDARY LOCKING DEVICES FOR BASEMENT SLIDE DOORS-PIN ASSY OR BOTTOM-MOUNTED BOLT ASSY All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frame's exterior surface. The surface mounted bolt assembly shall be installed at the base of the door. (Ord. No. 6600, § 1, 3-13-2008)
Piers/Caissons Inspection - Residential Passed 3/28/2012 (8:00) 3/28/2012 at 12:00 AM 09/12/2012
Misc
Resolved
10/12/2012
OK TO POUR BELOW: -FRONT PORCH PIERS APPROVED
Occupancy Inspection - Codes Residential Full C of O 10/12/2012 10/12/2012 at 12:00 AM 10/12/2012
Misc
Resolved
10/12/2012
-OBTAIN LAWN SPRINKLER PERMIT -FINAL GRADE, SOD, SPLASHBLOCKS -INSTALL SECONDARY LOCKING DEVICES FOR BASEMENT SLIDE DOORS-PIN ASSY OR BOTTOM-MOUNTED BOLT ASSY All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frame's exterior surface. The surface mounted bolt assembly shall be installed at the base of the door. (Ord. No. 6600, § 1, 3-13-2008)
Documents & Images
Date Uploaded File Type Document Name
12/09/2011 Letter Building Permit
12/09/2011 Letter Inspection Summary
12/09/2011 Plans 20111209161245239.pdf
01/18/2012 Letter Inspection Summary
01/19/2012 Letter Inspection Summary
01/19/2012 Letter Inspection Summary
03/28/2012 Letter Inspection Summary
05/15/2012 Letter Inspection Summary
05/25/2012 Letter Inspection Summary
05/29/2012 Letter Inspection Summary
06/04/2012 Letter Inspection Summary
06/05/2012 Letter Inspection Summary
06/06/2012 Activity Document 20120606100455016.pdf
06/08/2012 Activity Document 20120608125628346.pdf
09/06/2012 Letter Inspection Summary
09/12/2012 Letter Temporary Certificate of Occupancy
10/12/2012 Letter Field Certificate of Occupancy
10/15/2012 Letter Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home