Permit Application Status

PRRES20253369


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253369
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. ROOF TRUSSES. UNCOVERED DECK. STOP WORK ORDER generated on 08/28/2025 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/29/2025 12:00 AM by username 'Mitchell Schwarz'.
08/11/2025
08/15/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
taylor@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 08/15/2025
Water Meter Fee $791.53 $791.53 Paid 08/15/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 08/15/2025
Right of Way Permit Fee $85.00 $85.00 Paid 08/15/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/15/2025
Valuation Fee New Single Family $2,182.14 $2,182.14 Paid 08/15/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 08/15/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Sidewalk Inspection Pending
Electrical Service Inspection Pending
Misc
Corrective Action Required
10/28/2025
Ufer ground clam not installed correctly
All Rough Inspection - Residential Pending 11/4/2025 11/4/2025
Misc
Corrective Action Required
10/30/2025
-fire block all wall space to ceiling space at kitchen/garage wall. Multiple areas into furr downs and outs -provide insulation behind tub/shower in bath 4 -seal penetration into landing great room/stairwell wall -seal penetrations from hvac chase to ceiling space
Underslab Plumbing Inspection - Residential Failed 8/28/2025 8/28/2025 08/28/2025
Misc
Corrective Action Required
08/28/2025
Inspection denied footing poured without inspection
Footing Inspection - Residential Failed - Stop Work 8/28/2025 8/28/2025 08/28/2025
Misc
Corrective Action Required
08/28/2025
Footing poured without inspection
Footing Inspection - Residential Passed 8/29/2025 08/29/2025
Misc
Resolved
08/29/2025
Footing poured without inspection
Underslab Plumbing Inspection - Residential Passed 9/2/2025 9/2/2025 09/02/2025
Misc
Corrective Action Required
08/28/2025
Inspection denied footing poured without inspection
Sewer Service Inspection - R Passed 9/2/2025 9/2/2025 09/02/2025
Water Service Inspection - R Passed 9/2/2025 9/2/2025 09/02/2025
All Rough Inspection - Residential Partial 9/26/2025 9/26/2025 09/26/2025
Misc
Corrective Action Required
09/26/2025
Ok to cover portal frame
All Rough Inspection - Residential Not Ready 10/17/2025 10/17/2025 10/17/2025
Misc
Informational
10/17/2025
Ok to cover portal frame
Misc
Corrective Action Required
10/17/2025
-No city stamped plans on site -work still being performed Not ready
Gas Service Inspection - Residential Passed 10/17/2025 10/17/2025 10/17/2025
Electrical Service Inspection Failed 10/17/2025 10/17/2025 10/17/2025
Misc
Corrective Action Required
10/17/2025
Bonding clasp at gas line not installed properly
All Rough Inspection - Residential Failed 10/22/2025 10/22/2025 10/22/2025
Misc
Resolved
10/22/2025
Ok to cover portal frame
Misc
Resolved
10/22/2025
-No city stamped plans on site -work still being performed Not ready
Misc
Corrective Action Required
10/22/2025
- -missing stud pack under girder truss rear garage wall per plan -fire block all wall space to ceiling space at kitchen/garage wall. Multiple areas into furr downs and outs -plans call for steel column under beam S garage wall -provide insulation behind tub/shower in bath 4 -seal bottom plate and penetration into landing great room/stairwell wall -seal penetrations from hvac chase to ceiling space -missing lib in dining room -solid block above wall between cantilever joist above dining room -smoke/co may not be within 3’ of bath room. See bath 3 -fire block wall space to ceiling space at hall linen closet/hvac -provide Boca plate protection at dryer vent top plate -seal top plate penetration primary bath/bath 2 -minimum 3 studs at each exterior wall corner primary wall in closet -missing lateral bracing throughout -nail all trusses together to plan -sister over notched wall studs notched for anchor bolts in basement -minimum 3 studs at all exterior wall studs in basement -solid block between joists above beams in basement -missing triple and double joist above basement bath area
Electrical Service Inspection Not Ready 10/28/2025 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/17/2025
Ufer ground clam not installed correctly
All Rough Inspection - Residential Failed 10/28/2025 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/22/2025
-fire block all wall space to ceiling space at kitchen/garage wall. Multiple areas into furr downs and outs -provide insulation behind tub/shower in bath 4 -seal bottom plate and penetration into landing great room/stairwell wall -seal penetrations from hvac chase to ceiling space -fire block wall space to ceiling space at hall linen closet/hvac (see hall side) -seal top plate penetration primary bath/bath 2
All Rough Inspection - Residential Failed 10/30/2025 10/30/2025 10/30/2025
Misc
Corrective Action Required
10/28/2025
-fire block all wall space to ceiling space at kitchen/garage wall. Multiple areas into furr downs and outs -provide insulation behind tub/shower in bath 4 -seal penetration into landing great room/stairwell wall -seal penetrations from hvac chase to ceiling space
Documents & Images
Date Uploaded File Type Document Name
08/11/2025 BY #0360 - PERMIT APP
08/13/2025 Approved Plans APPROVED PLANS
08/13/2025 Approved Plans APPROVED TRUSS PACKAGE
08/13/2025 Plot Plan APPROVED PLOT PLAN
08/13/2025 Approved Plans APPROVED TRUSS LAYOUT
08/13/2025 Permit Codes Residential Plan Review
08/15/2025 Permit DS Building Permit
08/15/2025 Receipt Receipt for transaction:2025-006423
08/28/2025 Letter INSPECTION SUMMARY
08/28/2025 Letter Stop Work Order
08/28/2025 3RD Party Insp Report 0360 Bailey Farms Footing- Stamped
08/29/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
10/17/2025 Letter INSPECTION SUMMARY
10/17/2025 Letter INSPECTION SUMMARY
10/17/2025 Letter INSPECTION SUMMARY
10/22/2025 Letter INSPECTION SUMMARY
10/22/2025 Letter INSPECTION SUMMARY
10/23/2025 Receipt Receipt for transaction:2025-007963
10/28/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/30/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: