Permit Application Status

PRRES20253209


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253209
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO REFERENCE 20244003 FOR PREVIOUS INSPECTIONS
07/30/2025
09/05/2025
Locations
Contacts
Site360 LLC, Address:1813 SW Fountain Drive  
JGKELLEY2@GMAIL.COM  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Additional Permit Fee $1,858.00 $1,858.00 Paid 09/05/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 09/22/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Footing Inspection - Residential Pending
Foundation Inspection - Commercial Pending
Underslab Plumbing Inspection - Residential Pending
Underslab Electrical Inspection - Residential Pending
Occupancy Inspection - Codes Residential Pending
Sewer Service Inspection - R Pending
Misc
Corrective Action Required
11/12/2025
Unit 223 only
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
02/13/2026
- POST ADDRESS
All Rough Inspection - Residential Not Ready 9/17/2025 9/17/2025 09/17/2025
Misc
Corrective Action Required
09/17/2025
Not ready -Post address -Complete nailing pattern at CS-WSP panels, PFH and CS-PF -Horizontal seams must occur in middle 24" of portal legs
All Rough Inspection - Residential Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Corrective Action Required
09/17/2025
Exterior sheathing ok to cover
Erosion Control Inspection Residential Failed 09/25/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/25/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Provide gravel filter of min 6" lift of min 3/4" gravel at drive. -Clean silt from street
Piers/Caissons Inspection - Residential Failed 10/14/2025 10/14/2025 10/14/2025
Misc
Corrective Action Required
10/14/2025
-Piers to be 36" depth min -Remove loose gravel from bottom of pier
Piers/Caissons Inspection - Residential Passed 10/15/2025 10/15/2025 10/15/2025
Misc
Resolved
10/15/2025
-Piers to be 36" depth min -Remove loose gravel from bottom of pier
All Rough Inspection - Residential Failed 10/27/2025 10/27/2025 10/27/2025
Misc
Corrective Action Required
09/25/2025
Exterior sheathing ok to cover Attic framing ok to cover
Erosion Control Inspection Residential Failed 10/27/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/25/2025
10/27/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Provide gravel filter of min 6" lift of min 3/4" gravel at drive. -Clean silt from street
Gas Service Inspection - Residential Failed 10/27/2025 10/27/2025 10/27/2025
Gas Service Inspection - Residential Passed 10/27/2025
Erosion Control Inspection Residential Partial 10/29/2025 10/29/2025 10/29/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/29/2025
10/27/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Provide gravel filter of min 6" lift of min 3/4" gravel at drive. -Clean silt from street
Rated Assembly Inspection Partial 10/29/2025 10/29/2025 10/29/2025
Misc
Informational
10/29/2025
Above ceiling attic screw pattern ok , screw pattern and tape/mud ok at ductwork location, ok to install the ductwork
Sewer Service Inspection - R Passed 11/10/2025 11/10/2025 11/10/2025
Sewer Service Inspection - R Partial 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
11/12/2025
Unit 223 only
Water Service Inspection - R Passed 11/14/2025 11/14/2025 11/14/2025
All Rough Inspection - Residential Failed 1/8/2026 1/8/2026 01/08/2026
Misc
Corrective Action Required
10/27/2025
223 -Provide engineered correction and protect pex line where holes in joist bored closer than 2” and closer than 2” to bottom of joist at garage closet and powder room -Protect nm at top plate near kitchen exterior wall -Seal penetrations in vertical fire blocking of 2nd floor party wall at exterior wall -Seal gap at top plate in vertical fire blocking in garage at party wall in master bedroom -Provide proper slope at dwv in attic space -Support all dwv in attic space max 4’ oc -Support gas line in basement max 10’ oc -Secure electrical at sump pump -Fireblock gaps at soffits in basement bed, bath and at stairs -Holes drilled closer than 2” at basement mechanical room joists -Seal gap at beam pocket to garage -Fireblock stud to joist space at stair landings 225 -Protect nm at top plate mechanism chase and at entry -Protect nm at top plate of party wall, kitchen exterior wall -Protect nm at top plate in upstairs bed -Nail corner studs at upstairs bed -Provide proper slope at dwv in attic space and support max 48” oc -Protect nm bottom plate upstairs bed -Seal ALL plate penetrations in upstairs bathroom -Strap top plate lapped less than 24” at upstairs bath exterior corner -Seal nm penetration under stairs at first floor landing -Secure electrical at sump and grinder -Seal gaps in dead space Fireblock at column -1/2” plywood not approved Fireblocking material at soffit lines -Fireblock dead space in bedroom closet fur down -Seal penetration at basement bed fireblocking and Fireblock from stairs
Erosion Control Inspection Residential Failed 1/8/2026 1/8/2026 01/08/2026
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/08/2026
DEFICIENT EROSION CONTROL INSTALLATION. 1/8/26 Inlet Protection Curb Inlets: Manufactured products (Gutter buddy, Filter Sox, etc.) are to be properly installed at the opening of curb inlets, as secondary ESC BMPs, with primary BMPs installed upstream on-site. Proper installation requires the filter to fully extend beyond each end of the inlet opening, with clearance at the top for water overflow and no gaps between filters or against the curb. Installation is limited to locations where temporary ponding and sediment do not create a safety hazard or cause property damage. Regular inspection and maintenance of filters shall be performed and sediment build up should be removed. Any torn or damaged filters shall be replaced.
Erosion Control Inspection Residential Partial 1/13/2026 1/13/2026 01/13/2026
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/13/2026
DEFICIENT EROSION CONTROL INSTALLATION. 1/8/26 Inlet Protection Curb Inlets: Manufactured products (Gutter buddy, Filter Sox, etc.) are to be properly installed at the opening of curb inlets, as secondary ESC BMPs, with primary BMPs installed upstream on-site. Proper installation requires the filter to fully extend beyond each end of the inlet opening, with clearance at the top for water overflow and no gaps between filters or against the curb. Installation is limited to locations where temporary ponding and sediment do not create a safety hazard or cause property damage. Regular inspection and maintenance of filters shall be performed and sediment build up should be removed. Any torn or damaged filters shall be replaced.
All Rough Inspection - Residential Failed 1/13/2026 1/13/2026 01/13/2026
Misc
Corrective Action Required
01/08/2026
223 -Seal penetrations in vertical fire blocking of 2nd floor party wall at exterior wall -Fireblock gaps at soffits in basement at stairs -Holes drilled closer than 2” at basement mechanical room joists -Seal gap at beam pocket to garage -Fireblock stud to joist space at stair landings 225 -Protect nm at top plate of party wall -Protect nm at top plate in upstairs bed exterior wall -Seal ALL plate penetrations in upstairs bathroom -Seal nm penetration under stairs at first floor landing -Seal gaps in dead space Fireblock at column -1/2” plywood not approved Fireblocking material at basement -Fireblock dead space in bedroom closet fur down-Seal gaps -Seal penetration at basement bed fireblocking and Fireblock from stairs
All Rough Inspection - Residential Failed 1/15/2026 1/15/2026 01/15/2026
Misc
Corrective Action Required
01/13/2026
223 -Holes drilled closer than 2” at basement mechanical room joists-Provide engineered correction **OK to insulate and rock all other areas
All Rough Inspection - Residential Passed 01/16/2026
Misc
Resolved
01/16/2026
223 -Holes drilled closer than 2” at basement mechanical room joists-Provide engineered correction **OK to insulate and rock all other areas
Electrical Service Inspection Passed 1/22/2026 1/22/2026 01/22/2026
Rated Assembly Inspection Failed 2/13/2026 2/13/2026 02/13/2026
Misc
Informational
10/29/2025
Above ceiling attic screw pattern ok , screw pattern and tape/mud ok at ductwork location, ok to install the ductwork
Misc
Corrective Action Required
02/13/2026
- Screw pattern approved - Seal all gaps under ceiling joist and penetrations
Erosion Control Inspection Residential Failed 2/13/2026 02/13/2026
Misc
Corrective Action Required
02/13/2026
- POST ADDRESS
Driveway Inspection Partial 2/19/2026 2/19/2026 02/19/2026
Misc
Informational
02/19/2026
02/19/26 Thursday JMJ Driveway - Forms and materials passed pre-inspection.
Rated Assembly Inspection Passed 2/20/2026 02/20/2026
Misc
Resolved
02/20/2026
Above ceiling attic screw pattern ok , screw pattern and tape/mud ok at ductwork location, ok to install the ductwork
Misc
Resolved
02/20/2026
- Screw pattern approved - Seal all gaps under ceiling joist and penetrations
Driveway Inspection Passed 2/19/2026 2/19/2026 03/02/2026
Misc
Informational
02/19/2026
02/19/26 Thursday JMJ Driveway - Forms and materials passed pre-inspection.
Misc
Informational
03/02/2026
03/02/26 Monday JMJ Driveway - passed inspection.
Documents & Images
Date Uploaded File Type Document Name
07/30/2025 Application Form APPLICATION
09/04/2025 Letter LETTER FOR PLANS TO BE USED BY NEW OWNER
09/05/2025 Receipt Receipt for transaction: 2025-006927
09/05/2025 Letter OWNERSHIP DOC
09/05/2025 Permit Codes Residential Plan Review
09/05/2025 Letter DS Building Permit
09/05/2025 Plot Plan APPROVED PLOT PLAN
09/10/2025 Approved Plans APPROVED PLANS
09/17/2025 Letter INSPECTION SUMMARY
09/22/2025 Receipt Receipt for transaction:2025-007269
09/25/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
10/14/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/27/2025 Letter INSPECTION SUMMARY
10/27/2025 Letter INSPECTION SUMMARY
10/27/2025 Letter INSPECTION SUMMARY
10/27/2025 Letter INSPECTION SUMMARY
10/29/2025 Letter INSPECTION SUMMARY
10/29/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/14/2025 Letter INSPECTION SUMMARY
01/08/2026 Letter INSPECTION SUMMARY
01/08/2026 Letter INSPECTION SUMMARY
01/08/2026 3RD Party Insp Report Comment Response REO Engineering
01/13/2026 Letter INSPECTION SUMMARY
01/13/2026 Letter INSPECTION SUMMARY
01/15/2026 Letter INSPECTION SUMMARY
01/15/2026 Comment Response REO Engineering (Addendum)
01/16/2026 Letter INSPECTION SUMMARY
01/22/2026 Letter INSPECTION SUMMARY
02/13/2026 Letter INSPECTION SUMMARY
02/13/2026 Letter INSPECTION SUMMARY
02/19/2026 Letter INSPECTION SUMMARY
02/20/2026 Letter INSPECTION SUMMARY
03/02/2026 Letter INSPECTION SUMMARY
03/02/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home