Permit Application Status

PRRES20250185


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20250185
Building Permit - Residential
Issued
DJ23 INVESTMENTS LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES - DEFERRED.
01/20/2025
02/03/2025
07/29/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
DJ23 INVESTMENTS LLC, Address:7200 W 132ND ST  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DOUG@APGKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 02/03/2025
8350015-Water Meter Fee $748.03 $748.03 Paid 02/03/2025
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 02/03/2025
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/03/2025
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 02/03/2025
9110078-Valuation Fee New Single Family $1,561.08 $1,561.08 Paid 02/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
Driveway Inspection Pending
Misc
Informational
06/11/2025
06-11-25 Jamie S, DW is formed, but is not compacted. Grout will need to be done on the curb. Call back in for reinspection.
Footing Inspection - Residential Failed - Stop Work 03/21/2025
Misc
Corrective Action Required
03/21/2025
STOP WORK No footing inspection on file
Footing Inspection - Residential Passed 3/26/2025 03/26/2025
Misc
Resolved
03/26/2025
STOP WORK No footing inspection on file
Misc
Corrective Action Required
03/26/2025
-Footing inspected by third party.
Underslab Plumbing Inspection - Residential Passed 3/28/2025 3/28/2025 03/28/2025
All Rough Inspection - Residential Failed 4/17/2025 4/17/2025 04/17/2025
Misc
Corrective Action Required
04/17/2025
Portal frame only approved
Erosion Control Inspection Residential Failed 4/17/2025 04/17/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/17/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 4/18/2025 4/18/2025 04/18/2025
Misc
Corrective Action Required
04/17/2025
Portal frame only approved
Erosion Control Inspection Residential Failed 5/5/2025 05/05/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/05/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -maintain erosion control
Sewer Service Inspection - R Passed 5/5/2025 5/5/2025 05/05/2025
Water Service Inspection - R Partial 5/5/2025 05/05/2025
Misc
Corrective Action Required
05/05/2025
-pex from house to meter -partial
Water Service Inspection - R Passed 5/6/2025 5/6/2025 05/06/2025
Misc
Resolved
05/06/2025
-pex from house to meter -partial
All Rough Inspection - Residential Failed 5/9/2025 5/9/2025 05/09/2025
Misc
Resolved
05/09/2025
Portal frame only approved Porch is good as well
Misc
Corrective Action Required
05/09/2025
-no further inspections until erosion control is in compliance -provide full bearing for front porch header at garage east wall -strap the south east garage wall top plate where it’s lapped less than 24” -Nail plate under header at garage portal -missing stud packs at girder trusses per plans N wall -for block fireplace wall space to ceiling space -attach truss A1 per truss plans -strap the top plate in bed 3 where it’s over laped less than 24” -nail bed 2 exterior wall corner in the closet to plans -(on east garage wall) provide hold down for trusses at all bearing points -sister all over notched wall studs in basement where over notched for anchor bolts -strap top plate at the I beam where less than 24” overlap -missing sill plate and stud at NW basement tying walls together -provide future vent for future bathroom in basement
Gas Service Inspection - Residential Passed 5/9/2025 5/9/2025 05/09/2025
Electrical Service Inspection Passed 5/9/2025 5/9/2025 05/09/2025
Erosion Control Inspection Residential Failed 5/9/2025 5/9/2025 05/09/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -maintain erosion control
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/09/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -repair downed silt fence -spread gravel filter
All Rough Inspection - Residential Passed 5/29/2025 5/29/2025 05/29/2025
Misc
Resolved
05/29/2025
-no further inspections until erosion control is in compliance -provide full bearing for front porch header at garage east wall -strap the south east garage wall top plate where it’s lapped less than 24” -Nail plate under header at garage portal -missing stud packs at girder trusses per plans N wall -for block fireplace wall space to ceiling space -attach truss A1 per truss plans -strap the top plate in bed 3 where it’s over laped less than 24” -nail bed 2 exterior wall corner in the closet to plans -(on east garage wall) provide hold down for trusses at all bearing points -sister all over notched wall studs in basement where over notched for anchor bolts -strap top plate at the I beam where less than 24” overlap -missing sill plate and stud at NW basement tying walls together -provide future vent for future bathroom in basement
Erosion Control Inspection Residential Partial 5/19/2025 5/19/2025 05/30/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
05/19/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -repair downed silt fence -spread gravel filter
Erosion Control Inspection Residential Failed 5/30/2025 5/30/2025 05/30/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/30/2025
05-30-25 Jamie S, Silt fence on neighboring lot is down a dirt is coming up over it into the street. Silt fence needs to be reestablished or repaired. DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Partial 6/4/2025 6/4/2025 06/05/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/05/2025
05-30-25 Jamie S, Silt fence on neighboring lot is down a dirt is coming up over it into the street. Silt fence needs to be reestablished or repaired. DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. 06-05-25 Jamie S, Erosion control has been reestablished
Driveway Inspection Failed 6/11/2025 6/11/2025 06/11/2025
Misc
Informational
06/11/2025
06-11-25 Jamie S, DW is formed, but is not compacted. Grout will need to be done on the curb. Call back in for reinspection.
Sidewalk Inspection Failed 6/11/2025 6/11/2025 06/11/2025
Misc
Informational
06/11/2025
06-11-25 Jamie S, SW is formed, but is not compacted Call back in for reinspection.
Documents & Images
Date Uploaded File Type Document Name
01/20/2025 RS 113 Permit Application Signed (1)
01/20/2025 RS 113 Tax Application Signed
01/23/2025 Permit Codes Residential Plan Review
01/31/2025 Approved Plans APPROVED PLANS
01/31/2025 Plot Plan APPROVED PLOT PLAN
01/31/2025 Approved Plans APPROVED TRUSS PACKAGE
01/31/2025 Approved Plans APPROVED TRUSS LAYOUT
01/31/2025 Permit Codes Residential Plan Review
02/03/2025 Permit DS Building Permit
02/03/2025 Receipt Receipt for transaction:2025-000661
03/21/2025 Letter Stop Work Order
03/26/2025 3RD Party Insp Report FOOTING INSPECTION
03/26/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/19/2025 Letter INSPECTION SUMMARY
05/29/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter INSPECTION SUMMARY
06/05/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home