Permit Application Status

PRRES20245644


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245644
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX. FINISHED/UNFINISHED BASEMENT. COVERED PORCH. SUSPENDED SLAB
10/23/2024
11/04/2024
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,556.64 $2,556.64 Paid 11/04/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/04/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 11/04/2024
8331401-Water Tap Fee $7,946.00 $7,946.00 Paid 11/04/2024
8350015-Water Meter Fee $1,496.06 $1,496.06 Paid 11/04/2024
8331507-Sanitary Sewer Development Fee $4,570.00 $4,570.00 Paid 11/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Corrective Action Required
02/26/2025
Replace or repair silt fence that has been damaged along the front south side, NW corner and along the north side of the lot Full erosion control measures must be in place and properly maintained until CofO
Rated Assembly Inspection Pending
Misc
Informational
04/23/2025
Attic space and floor joist space-okay
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
05/01/2025
Both sides -Address ridge beam not contentious
Footing Inspection - Residential Partial 11/26/2024 11/26/2024
Misc
Corrective Action Required
11/26/2024
3rd party pier letter uploaded only
Footing Inspection - Residential Passed 12/6/2024 12/06/2024
Misc
Resolved
12/06/2024
3rd party pier letter uploaded only
Miscellaneous Correction
Informational
12/06/2024
Footing inspection was completed by a third party
Underslab Electrical Inspection - Residential Passed 12/16/2024 12/16/2024 12/16/2024
Misc
Corrective Action Required
12/16/2024
- 1401 & 1403
Sewer Service Inspection - R Partial 12/23/2024 12/23/2024 12/23/2024
Misc
Corrective Action Required
12/23/2024
1401 approved only
Sewer Service Inspection - R Passed 12/24/2024 12/24/2024 12/24/2024
Misc
Informational
12/24/2024
1401 and 1403 approved
Water Service Inspection - R Passed 12/27/2024 12/27/2024 12/27/2024
Erosion Control Inspection Residential Failed 12/27/2024 12/27/2024 12/27/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/27/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/27/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/27/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 1/30/2025 01/30/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/30/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
01/30/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
01/30/2025
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Miscellaneous Correction
Corrective Action Required
01/30/2025
Replace or repair silt fence that has been damaged along the front south side, NW corner and along the north side of the lot Full erosion control measures must be in place and properly maintained until CofO
Underslab Plumbing Inspection - Residential Passed 1/30/2025 1/30/2025 01/30/2025
Suspended Slab Inspection Passed 2/26/2025 02/26/2025
Informational
02/26/2025
Garage suspended slab passed by a third party
Erosion Control Inspection Residential Failed 2/26/2025 02/26/2025
Miscellaneous Correction
Corrective Action Required
01/30/2025
Replace or repair silt fence that has been damaged along the front south side, NW corner and along the north side of the lot Full erosion control measures must be in place and properly maintained until CofO
Rated Assembly Inspection Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Informational
04/23/2025
Attic space and floor joist space-okay
Gas Service Inspection - Residential Passed 4/23/2025 4/23/2025 04/23/2025
Electrical Service Inspection Passed 4/23/2025 4/23/2025 04/23/2025
All Rough Inspection - Residential Failed 4/23/2025 4/23/2025 04/23/2025
Misc
Corrective Action Required
04/23/2025
Both sides -Address ridge beam not contentious -missing rafter to ceiling joist connection at N AND S exterior walls where rafters landing on multiple blocks 1401 -strap top plate where lapped less than 24” inches front bedroom closet -fireblock wall space to ceiling space at rear kitchen wall (1/2” osb not approved for fire blocking) -seal top plate penetration right of rear slider -fireblock into furr down bed 4 closet --(2) full height studs each side of rear basement wall header 1403 -fire block wall space to ceiling space at kitchen pantry -anchor bolts to be in the middle 1/3 of sill plate SW corner garage
All Rough Inspection - Residential Failed 5/1/2025 5/1/2025 05/01/2025
Misc
Corrective Action Required
04/23/2025
Both sides -Address ridge beam not contentious
Documents & Images
Date Uploaded File Type Document Name
10/23/2024 Application - Lot 41
10/23/2024 Tax Form - Lot 41
10/30/2024 Plot Plan APPROVED PLOT PLAN
10/30/2024 Approved Plans APPROVED PLANS
10/30/2024 Permit Codes Residential Plan Review
11/04/2024 Permit DS Building Permit
11/04/2024 Receipt Receipt for transaction: 2024-008743
11/25/2024 3RD Party Insp Report 1401-03 SW Winthrop Ter_PIER INSP_2024-11-22
11/26/2024 Letter INSPECTION SUMMARY
12/05/2024 1401-03 Winthrop Ter_FTG INSP_2024-12-02
12/06/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
02/25/2025 2025_02_10_1401-03 SW Winthrop Terrace_Gslab_Report_Sealed
02/26/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
05/01/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home