Permit Application Status

PRRES20245643


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245643
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX - FINISHED AND UNFINISHED BASEMENT - COVERED PORCH - SUSPENDED SLAB
10/23/2024
11/04/2024
04/23/2025
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
KEVIN@ROCKCREEKHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,574.17 $2,574.17 Paid 11/04/2024
8331507-Sanitary Sewer Development Fee $4,570.00 $4,570.00 Paid 11/04/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/04/2024
8331401-Water Tap Fee $7,946.00 $7,946.00 Paid 11/04/2024
8350015-Water Meter Fee $1,496.06 $1,496.06 Paid 11/04/2024
7232302-Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 11/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
02/26/2025
Erosion control is in place at the time of inspection
Footing Inspection - Residential Passed 11/26/2024 11/26/2024
Underslab Electrical Inspection - Residential Passed 12/16/2024 12/16/2024 12/16/2024
Misc
Informational
12/16/2024
1407 & 1409
Sewer Service Inspection - R Partial 12/19/2024 12/19/2024 12/19/2024
Misc
Informational
12/19/2024
1407 approved only
Sewer Service Inspection - R Passed 12/20/2024 12/20/2024 12/20/2024
Misc
Resolved
12/20/2024
1407 approved only
Water Service Inspection - R Partial 12/20/2024 12/20/2024 12/20/2024
Misc
Informational
12/20/2024
1407 only
Water Service Inspection - R Passed 12/20/2024 12/20/2024 12/20/2024
Misc
Resolved
12/20/2024
1407 only
Underslab Plumbing Inspection - Residential Passed 1/31/2025 1/31/2025 01/31/2025
Erosion Control Inspection Residential Failed 1/31/2025 01/31/2025
Miscellaneous Correction
Corrective Action Required
01/31/2025
Repair or replace damaged silt fence at the front of the lot next to the street
Suspended Slab Inspection Passed 2/26/2025 02/26/2025
Informational
02/26/2025
Garage suspended slab passed by a third party
Erosion Control Inspection Residential Partial 2/26/2025 02/26/2025
Miscellaneous Correction
Resolved
02/26/2025
Repair or replace damaged silt fence at the front of the lot next to the street
Miscellaneous Correction
Informational
02/26/2025
Erosion control is in place at the time of inspection
Electrical Service Inspection Failed 4/16/2025 4/16/2025 04/16/2025
Misc
Corrective Action Required
04/16/2025
Use correct size wire for bonding gasline
Gas Service Inspection - Residential Passed 4/16/2025 4/16/2025 04/16/2025
Rated Assembly Inspection Failed 4/16/2025 4/16/2025 04/16/2025
Misc
Corrective Action Required
04/16/2025
Basement-okay Fire caulk penetrations from ridge in attic
All Rough Inspection - Residential Failed 4/16/2025 4/16/2025 04/16/2025
Misc
Corrective Action Required
04/16/2025
Both sides Use correct size wire for bonding gas line Address ridge beam not contenuious 1407 -anchor bolts to be in the middle 1/3 of sill plate -protect all NM Within 6’ of attic access -strap top plate lapped less than 24” at kitchen exterior wall -fireblock wall space to ceiling space at rear exterior wall where ceiling furred down --header across rear wall in basement requires double full length studs each side. 1409 -missing anchor bolts SW Garage -protect NM within 6’ of attic access -nail plate under header at garage portal into header per design -fireblock dead space into ceiling space bath 2 -fireblock rear exterior wall wall space to ceiling space -sister notched exterior wall studs where over notched for anchor bolts bed 4 -header across rear wall in basement requires double full length studs each side.
Rated Assembly Inspection Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Corrective Action Required
04/16/2025
Basement-okay attic- okay
All Rough Inspection - Residential Failed 4/23/2025 4/23/2025 04/23/2025
Misc
Corrective Action Required
04/16/2025
Both sides Address ridge beam not contenuious 1407 -strap top plate lapped less than 24” at kitchen exterior wall 1409 -protect NM within 6’ of attic access
Electrical Service Inspection Passed 4/23/2025 4/23/2025 04/23/2025
Misc
Resolved
04/23/2025
Use correct size wire for bonding gasline
All Rough Inspection - Residential Failed 4/24/2025 4/24/2025 04/24/2025
Misc
Corrective Action Required
04/23/2025
Both sides Address ridge beam not contenuious Okay to insulate
Rated Assembly Inspection Failed 5/13/2025 5/13/2025 05/13/2025
Misc
Corrective Action Required
04/23/2025
Basement-okay attic- okay Inspection denied House locked no code for entry. Provide better access to stoop at 1407 Mitchell Schwarz 05/13/25 08:17 AM
Rated Assembly Inspection Passed 5/14/2025 5/14/2025 05/14/2025
Misc
Resolved
05/14/2025
Basement-okay attic- okay Inspection denied House locked no code for entry. Provide better access to stoop at 1407 Mitchell Schwarz 05/13/25 08:17 AM
All Rough Inspection - Residential Passed 5/22/2025 5/22/2025 05/22/2025
Misc
Resolved
05/22/2025
Both sides Address ridge beam not contenuious Okay to insulate
Documents & Images
Date Uploaded File Type Document Name
10/23/2024 Application - Lot 40
10/23/2024 Tax Form - Lot 40
10/25/2024 Permit Codes Residential Plan Review
10/31/2024 Approved Plans APPROVED PLANS
10/31/2024 Plot Plan APPROVED PLOT PLAN
10/31/2024 Permit Codes Residential Plan Review
11/04/2024 Permit DS Building Permit
11/04/2024 Receipt Receipt for transaction: 2024-008741
11/25/2024 3RD Party Insp Report 1407-09 SW Winthrop Ter_PIER INSP_2024-11-21
11/25/2024 3RD Party Insp Report 1407-09 SW Winthrop Ter_FTG INSP_2024-11-22
11/26/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
02/25/2025 2025_02_10_1407-09 SW Winthrop Terrace_Gslab_Report_Sealed
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
04/16/2025 Letter INSPECTION SUMMARY
04/16/2025 Letter INSPECTION SUMMARY
04/16/2025 Letter INSPECTION SUMMARY
04/16/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
05/13/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
05/21/2025 Engineer Report/Study ENGINEERING LETTER
05/22/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home