Permit Application Status

PRRES20243851


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243851
Building Permit - Residential
Issued
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
07/24/2024
08/02/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 08/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/02/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/02/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 08/02/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 08/02/2024
9110078-Valuation Fee New Single Family $2,227.05 $2,227.05 Paid 08/02/2024
9110078-Additional Permit Fee $179.12 $179.12 Paid 10/10/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/31/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/29/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish control methods at perimeter and maintain gravel filter
Footing Inspection - Residential Passed 9/6/2024 09/06/2024
Erosion Control Inspection Residential Partial 09/06/2024
Misc
Informational
09/06/2024
In compliance at time of inspection
Erosion Control Inspection Residential Partial 09/30/2024
Misc
Informational
09/06/2024
In compliance at time of inspection
Underslab Plumbing Inspection - Residential Failed 9/30/2024 9/30/2024 09/30/2024
Misc
Corrective Action Required
09/30/2024
Not ready -Inspections not ready by 7 am need to be scheduled for the next day
Erosion Control Inspection Residential Failed 10/1/2024 10/01/2024
Misc
Resolved
10/01/2024
In compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE AND CLEAN GRAVEL FROM STREETS
Underslab Plumbing Inspection - Residential Passed 10/1/2024 10/1/2024 10/01/2024
Misc
Resolved
10/01/2024
Not ready -Inspections not ready by 7 am need to be scheduled for the next day
Erosion Control Inspection Residential Failed 10/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
Erosion Control Inspection Residential Failed 10/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/24/2024
10/24/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 11/1/2024 11/1/2024 11/01/2024
Misc
Corrective Action Required
11/01/2024
11/1/24 Portal frame inspection only: -All horizontal joints are to be in middle 24" of portal leg
Erosion Control Inspection Residential Partial 11/1/2024 11/1/2024 11/01/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Resolved
11/01/2024
10/24/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Not Ready 11/4/2024 11/4/2024 11/04/2024
Misc
Resolved
11/04/2024
11/1/24 Portal frame inspection only: -All horizontal joints are to be in middle 24" of portal leg
Miscellaneous Correction
Corrective Action Required
11/04/2024
- All horizontal joints are to be in middle 24" of portal leg - Horizontal joints can not be at the header to portal leg Not ready for inspection This is a Garage PFH sheeting inspection only
All Rough Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Miscellaneous Correction
Resolved
11/07/2024
- All horizontal joints are to be in middle 24" of portal leg - Horizontal joints can not be at the header to portal leg Not ready for inspection This is a Garage PFH sheeting inspection only
Miscellaneous Correction
Corrective Action Required
11/07/2024
Garage PFH, front and back porch above ceiling and CS-PF around the breakfast nook all passed and are ok to cover This is a partial pass only
Erosion Control Inspection Residential Partial 12/03/2024
Sewer Service Inspection - R Passed 12/10/2024
Water Service Inspection - R Passed 12/11/2024 12/11/2024 12/11/2024
Electrical Service Inspection Passed 1/24/2025 1/24/2025 01/24/2025
Gas Service Inspection - Residential Passed 1/24/2025 1/24/2025 01/24/2025
Erosion Control Inspection Residential Partial 1/24/2025 1/24/2025 01/24/2025
All Rough Inspection - Residential Failed 1/24/2025 1/24/2025 01/24/2025
Miscellaneous Correction
Corrective Action Required
11/07/2024
-Provide anchor bolts at plate breaks in garage -Anchor bolts to be in middle third of plate at garage -Install tension straps at PFH header to jack studs per detail -Solid block joists above all beams and load bearing walls throughout -Hip joist over notched at 2 car bay exterior corner -Strap top plates lapped less than 24" at 1 car bay -Seal joist space return air penetrations at owners entry -Missing (2) 2x4 at owners entry -Missing LIB throughout -Missing (2) 2x4 at utility closet window -Missing (2) 2x6 at utility closet corner -Install all missing roof boots -Missing (2) 2x4 at deck doorway -Properly support hip above deck -Seal bottom plate at bed 2 -Provide receptacle at entry -Nail all exterior corners max min 12" oc -Add stud under beam in bed 2 -Protect electrical at master bed return air space -Missing EC 2 800 lb hold down device at bed 4 -Missing (2) 2x4 at bed 4 windows -Missing (2) 2x4 bed 4 closet -Provide lateral restraint at all joists above load bearing walls -Strap at over bored top plate shared bath must extend min 6" each side of bored hole -Missing double 2x4s throughout bed 5 and shared bath -Support vent above laundry -Protect dryer duct 2” below plate line at laundry -Fireblock top of duct chase -Provide lateral restraint at beam above living room window -FB dead space at stairs -Missing EC 2 800lb hold down device at basement corner -Missing (2) 2x4 at mechanical -Missing double studs at exterior basement window wall -Solid block joists above beams in basement -Install blocking between joists 48" oc under island -FB top of dead space at basement bath -Tighten anchor bolts in basement
Erosion Control Inspection Residential Failed 01/29/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/29/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish control methods at perimeter and maintain gravel filter
All Rough Inspection - Residential Failed 1/29/2025 1/29/2025 01/29/2025
Miscellaneous Correction
Corrective Action Required
01/24/2025
-Missing (2) 2x4 at owners entry -LIB IN PANTRY TO BE 5’ 9”, -LIB IN UTILITY TO BE 5’ 2” -Missing (2) 2x4 at utility closet window -Missing (2) 2x6 at utility closet corner -Missing (2) 2x4 at deck doorway -Protect electrical at master bed return air space-PAN OFF BOX -Missing (2) 2x4 at bed 4 windows -Missing (2) 2x4 bed 4 closet -Missing double 2x4s throughout bed 5 and shared bath
All Rough Inspection - Residential Passed 1/31/2025 1/31/2025 01/31/2025
Miscellaneous Correction
Resolved
01/31/2025
-Missing (2) 2x4 at owners entry -Missing (2) 2x4 at utility closet window -Missing (2) 2x6 at utility closet corner -Missing (2) 2x4 at deck doorway -Missing (2) 2x4 at bed 4 windows -Missing (2) 2x4 bed 4 closet -Missing double 2x4s throughout bed 5 and shared bath
Driveway Inspection Partial 3/3/2025 3/3/2025 03/03/2025
Misc
Informational
03/03/2025
03/03/25 Monday Pre-inspection of forms and materials for driveway passed inspection.
Sidewalk Inspection Partial 3/3/2025 3/3/2025 03/03/2025
Misc
Informational
03/03/2025
03/03/25 Monday JMJ Pre-inspection of sidewalk forms and materials passed inspection.
Driveway Inspection Passed 3/7/2025 3/7/2025 03/07/2025
Misc
Informational
03/03/2025
03/03/25 Monday Pre-inspection of forms and materials for driveway passed inspection.
Misc
Informational
03/07/2025
Driveway passed final inspection.
Sidewalk Inspection Passed 3/7/2025 3/7/2025 03/07/2025
Misc
Informational
03/03/2025
03/03/25 Monday JMJ Pre-inspection of sidewalk forms and materials passed inspection.
Misc
Informational
03/07/2025
03/07/25 Friday JMJ Sidewalk passed final inspection.
Documents & Images
Date Uploaded File Type Document Name
07/25/2024 Approved Plans APPROVED PLANS
07/25/2024 Plot Plan APPROVED PLOT PLAN
08/02/2024 Updated - WR131 - Lee's Summit Permit Application Packet
08/02/2024 Permit Codes Residential Plan Review
08/02/2024 Permit DS Building Permit
08/02/2024 Receipt Receipt for transaction:2024-006507
09/05/2024 2139 NW Killarney Ln_PIER INSP_2024-09-03
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/09/2024 WR131 - Lee's Summit Basement Finish Application -Scope_of_Work_Statement_Fillable (1)
09/11/2024 Coverletter
09/11/2024 24-342 BASEMENT FINISH2
09/12/2024 Approved Plans APPROVED BASEMENT FINISH
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 INSPECTION SUMMARY
10/10/2024 Receipt Receipt for transaction:2024-008252
10/24/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/31/2025 2025_01_30_Lot 131 Woodside Ridge_Apex_Plan Review Comments_Response
01/31/2025 Receipt Receipt for transaction:2025-000635
01/31/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/28/2025 2139 NW Killarney Lane_Framing Evaluation Report_3-28-25
03/31/2025 2139 NW Killarney Lane_Framing Evaluation Report_3-28-25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.