Permit Application Status

PRRES20243018


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243018
Building Permit - Residential
Certificate of Occupancy
DJ23 INVESTMENTS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES ( DEF )
06/12/2024
06/20/2024
12/16/2024
02/14/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
DJ23 INVESTMENTS LLC, Address:7200 W 132ND ST  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/20/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/20/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 06/20/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/20/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/20/2024
9110078-Valuation Fee New Single Family $1,602.87 $1,602.87 Paid 06/20/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/26/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/10/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Not Ready 7/10/2024 7/10/2024 07/10/2024
Miscellaneous Correction
Corrective Action Required
07/10/2024
City stamped plans are not on job site Footing inspection was not done Not ready for inspection
Sewer Service Inspection - R Passed 7/15/2024 7/15/2024 07/15/2024
Water Service Inspection - R Failed 7/15/2024 07/15/2024
Miscellaneous Correction
Informational
07/15/2024
PEX ran about 20 feet out toward the curb from the foundation. Okay to cover PEX only This is a partial pass only
Erosion Control Inspection Residential Partial 7/17/2024 07/17/2024
Miscellaneous Correction
Informational
07/17/2024
Full erosion control measures are in place and must be maintained until CofO
Water Service Inspection - R Passed 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
PEX ran about 20 feet out toward the curb from the foundation. Okay to cover PEX only This is a partial pass only
Footing Inspection - Residential Passed 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
City stamped plans are not on job site Footing inspection was not done Not ready for inspection
Miscellaneous Correction
Informational
07/18/2024
Footing passed by third party. Exterior piers were not mentioned in footing report
Underslab Plumbing Inspection - Residential Passed 7/19/2024 7/19/2024 07/19/2024
All Rough Inspection - Residential Partial 8/5/2024 8/5/2024 08/05/2024
Misc
Informational
08/05/2024
GARAGE PORTAL FRAME AND FRONT PORCH TRUSS INSPECTION ONLY. Passed AF 8/5/24
Erosion Control Inspection Residential Partial 8/16/2024 08/16/2024
Miscellaneous Correction
Informational
07/17/2024
Full erosion control measures are in place and must be maintained until CofO
Electrical Service Inspection Passed 8/23/2024 8/23/2024 08/23/2024
Erosion Control Inspection Residential Partial 8/23/2024 08/23/2024
Miscellaneous Correction
Informational
08/16/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 8/23/2024 8/23/2024 08/23/2024
Misc
Informational
08/05/2024
GARAGE PORTAL FRAME AND FRONT PORCH TRUSS INSPECTION ONLY. Passed AF 8/5/24
Miscellaneous Correction
Corrective Action Required
08/23/2024
1905 SW Hightown. All rough •Nail garage corners to code •Tighten down anchor bolts in garage •Garage anchor bolts in the sole plate needs to be in the middle 1/3 •Missing nails in girder truss in garage at off set between overhead doors •Fire block top of chase in garage •Floor above garage chase has holes that needs to be fire blocked •Fire block at the top of the garage chase for DWV •Fourth LVL in garage at steel post is not fully supported •Nail 2x6 to 2x4 interior wall in entry •Fire block top of chase in entry •Fire block top of chases in living room •Add electrical nail guards throughout •Nails missing in triple girder in laundry/closet upstairs •Vertically support 2x6 front entry wall under the stairs to the foundation •Floor joist hanger under stairs in basement are missing nails Gas was not inspected at the time of all rough. Builder canceled gas inspection
Gas Service Inspection - Residential Passed 8/28/2024 8/28/2024 08/28/2024
Erosion Control Inspection Residential Partial 8/28/2024 08/28/2024
Miscellaneous Correction
Informational
08/23/2024
Full erosion control measures are in place and must be maintained until CofO
Suspended Slab Inspection Passed 8/28/2024 08/28/2024
Miscellaneous Correction
Informational
08/28/2024
Front porch was inspected by a third party
All Rough Inspection - Residential Passed 8/28/2024 8/28/2024 08/28/2024
Misc
Resolved
08/28/2024
GARAGE PORTAL FRAME AND FRONT PORCH TRUSS INSPECTION ONLY. Passed AF 8/5/24
Miscellaneous Correction
Resolved
08/28/2024
1905 SW Hightown. All rough •Nail garage corners to code •Tighten down anchor bolts in garage •Garage anchor bolts in the sole plate needs to be in the middle 1/3 •Missing nails in girder truss in garage at off set between overhead doors •Fire block top of chase in garage •Floor above garage chase has holes that needs to be fire blocked •Fire block at the top of the garage chase for DWV •Fourth LVL in garage at steel post is not fully supported •Nail 2x6 to 2x4 interior wall in entry •Fire block top of chase in entry •Fire block top of chases in living room •Add electrical nail guards throughout •Nails missing in triple girder in laundry/closet upstairs •Vertically support 2x6 front entry wall under the stairs to the foundation •Floor joist hanger under stairs in basement are missing nails Gas was not inspected at the time of all rough. Builder canceled gas inspection
Erosion Control Inspection Residential Partial 9/6/2024 09/06/2024
Miscellaneous Correction
Informational
08/28/2024
Full erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 10/7/2024 10/7/2024 10/07/2024
Misc
Informational
10/07/2024
10-7-24 DP. DW was formed, aggregate compacted, approved to pour
Driveway Inspection Passed 10/16/2024 10/16/2024 10/16/2024
Misc
Informational
10/07/2024
10-7-24 DP. DW was formed, aggregate compacted, approved to pour 10-16-24 DP DW was poured, forms have been removed. Passed.
Erosion Control Inspection Residential Failed 10/28/2024 10/28/2024
Miscellaneous Correction
Resolved
10/28/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
10/28/2024
Erosion control measures are not installed at the front of the property Full erosion control measures must be in place and properly maintained until CofO
Occupancy Inspection - Codes Residential Failed 10/28/2024 10/28/2024 10/28/2024
Miscellaneous Correction
Corrective Action Required
10/28/2024
1905 SW Hightown. Occupancy Back porch steps riser height are not to code on 3/8 of an inch variance Fire block bottom of chases in garage Stair riser height from main living area to basement can not exceed 7 3/4 inches Lights in basement are not installed Secure electrical above HWT Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Corrective Action Required
10/28/2024
Erosion control measures are not installed at the front of the property Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/01/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. No erosion located on the property Full erosion control measures must be installed and properly maintained until CofO
Erosion Control Inspection Residential Partial 11/6/2024 11/06/2024
Miscellaneous Correction
Resolved
11/06/2024
Erosion control measures are not installed at the front of the property Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. No erosion located on the property Full erosion control measures must be installed and properly maintained until CofO
Miscellaneous Correction
Informational
11/06/2024
Full erosion control measures are in place and must be properly maintained until CofO
Erosion Control Inspection Residential Passed 12/27/2024 12/27/2024
Miscellaneous Correction
Resolved
12/27/2024
Full erosion control measures are in place and must be properly maintained until CofO
Plot Plan Inspection Passed 12/27/2024 12/27/2024
Occupancy Inspection - Codes Residential Not Ready 12/27/2024 12/27/2024 12/27/2024
Miscellaneous Correction
Corrective Action Required
10/28/2024
1905 SW Hightown. Occupancy Back porch steps riser height are not to code on 3/8 of an inch variance Fire block bottom of chases in garage Stair riser height from main living area to basement can not exceed 7 3/4 inches Lights in basement are not installed Secure electrical above HWT Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations House is locked and no access code is provided-not ready for inspection KBEARD
Occupancy Inspection - Codes Residential Failed 1/16/2025 1/16/2025 01/16/2025
Miscellaneous Correction
Resolved
01/16/2025
1905 SW Hightown. Occupancy Back porch steps riser height are not to code on 3/8 of an inch variance Fire block bottom of chases in garage Stair riser height from main living area to basement can not exceed 7 3/4 inches Lights in basement are not installed Secure electrical above HWT Sod, splash pads and sump pump extensions are not installed Seal all exterior penetrations House is locked and no access code is provided-not ready for inspection KBEARD
Miscellaneous Correction
Corrective Action Required
01/16/2025
Back porch stair risers are at 7 inches, 7 inches and at the top of the threshold is only 6 inches Stair raiser height by code can not very by more than 3/8 of an inch Pay $75fee associated with this permit
Occupancy Inspection - Codes Residential Full C of O 2/14/2025 2/14/2025 02/14/2025
Miscellaneous Correction
Resolved
02/14/2025
Back porch stair risers are at 7 inches, 7 inches and at the top of the threshold is only 6 inches Stair raiser height by code can not very by more than 3/8 of an inch Pay $75fee associated with this permit
Documents & Images
Date Uploaded File Type Document Name
06/12/2024 RS 127 License_Tax_Application Signed
06/12/2024 RS 127 Permit Application Signed
06/13/2024 Permit Codes Residential Plan Review
06/19/2024 Permit Codes Residential Plan Review
06/19/2024 Application Form RS 127 Permit Application Signed
06/19/2024 Plot Plan APPROVED PLOT PLAN
06/19/2024 Permit Codes Residential Plan Review
06/20/2024 Permit DS Building Permit
06/20/2024 Receipt Receipt for transaction:2024-004955
06/26/2024 Approved Plans APPROVED REVISED PLANS
07/10/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 3RD Party Insp Report Footing inspection
07/18/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/26/2024 3RD Party Insp Report THIRD PARTY SUSPENDED STOOP INSPECTION
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter Codes Residential Plan Review
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/26/2024 Receipt Receipt for transaction:2024-007960
10/07/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
02/10/2025 Receipt Receipt for transaction:2025-000865
02/14/2025 Letter Field Certificate of Occupancy
02/14/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home