Summary
PRRES20242860
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX. FINISHED/UNFINSHED BASEMENT. SUSPENDED SLAB. COVERED PATIO.
06/04/2024
07/11/2024
12/24/2024
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,586.73 $2,586.73 Paid 07/11/2024
8331401-Water Tap Fee $7,946.00 $7,946.00 Paid 07/11/2024
8350015-Water Meter Fee $1,496.06 $1,496.06 Paid 07/11/2024
8331507-Sanitary Sewer Development Fee $4,570.00 $4,570.00 Paid 07/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/11/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 07/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
01/16/2025
Erosion control is in compliance at the time of inspection
Driveway Inspection Pending
Misc
Informational
03/24/2025
3-24-25 BR Driveway is formed up with aggerate is placed and compacted. Ready for concrete.
Footing Inspection - Residential Passed 9/10/2024 9/10/2024 09/10/2024
Water Service Inspection - R Failed 10/3/2024 10/3/2024 10/03/2024
Miscellaneous Correction
Corrective Action Required
10/03/2024
1438 PEX ran 6 feet out from the foundation and is okay to cover 1436 Not ready for inspection This is a partial inspection only. Water inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Sewer Service Inspection - R Failed 10/3/2024 10/3/2024 10/03/2024
Miscellaneous Correction
Corrective Action Required
10/03/2024
1438 Sewer passed and is okay to cover 1436 Not ready for inspection This is a partial pass only Sewer inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Erosion Control Inspection Residential Failed 10/3/2024 10/03/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/03/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Clean gravel from the street and repair or replace silt fence at the front of the lot at the street that has been torn down and is no longer effective Full erosion control measures must be in place and maintained until CofO
Sewer Service Inspection - R Failed 10/3/2024 10/3/2024 10/03/2024
Miscellaneous Correction
Resolved
10/03/2024
1438 Sewer passed and is okay to cover 1436 Not ready for inspection This is a partial pass only Sewer inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Miscellaneous Correction
Corrective Action Required
10/03/2024
Both units passed sewer inspection and are okay to cover Sewer inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Water Service Inspection - R Failed 10/3/2024 10/3/2024 10/03/2024
Miscellaneous Correction
Resolved
10/03/2024
1438 PEX ran 6 feet out from the foundation and is okay to cover 1436 Not ready for inspection This is a partial inspection only. Water inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Miscellaneous Correction
Corrective Action Required
10/03/2024
PEX ran 6 feet out from the foundation and is okay to cover for both units This is a partial inspection only. Water inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Underslab Electrical Inspection - Residential Passed 10/4/2024 10/4/2024 10/04/2024
Misc
Informational
10/04/2024
For both 1436, 1438
Water Service Inspection - R Passed 10/7/2024 10/7/2024 10/07/2024
Miscellaneous Correction
Resolved
10/07/2024
PEX ran 6 feet out from the foundation and is okay to cover for both units This is a partial inspection only. Water inspection failed because of erosion control being damaged at the front of the lot and gravel is in the street
Erosion Control Inspection Residential Failed 10/7/2024 10/7/2024 10/07/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/03/2024
**Sewer and water completed. Restore erosion control to compliance Clean gravel from the street and repair or replace silt fence at the front of the lot at the street that has been torn down and is no longer effective Full erosion control measures must be in place and maintained until CofO
Underslab Plumbing Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Erosion Control Inspection Residential Failed 10/11/2024 10/11/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/11/2024
**Sewer and water completed. Restore erosion control to compliance Clean gravel from the street and repair or replace silt fence at the front of the lot at the street that has been torn down and is no longer effective Full erosion control measures must be in place and maintained until CofO
Miscellaneous Correction
Corrective Action Required
10/11/2024
Gravel from the street to the foundation has been covered with dirt from dirt work being done. Restore as soon as possible Full erosion control measures must be in place and properly maintained until CofO
Sewer Service Inspection - R Passed 10/11/2024 10/11/2024 10/11/2024
Miscellaneous Correction
Informational
10/11/2024
- 1436 and 1438
Suspended Slab Inspection Passed 10/24/2024 10/24/2024
Miscellaneous Correction
Informational
10/24/2024
Garage suspended slab passed by a third party
Electrical Service Inspection Passed 1/13/2025 1/13/2025 01/13/2025
Rated Assembly Inspection Failed 1/13/2025 1/13/2025 01/13/2025
Miscellaneous Correction
Corrective Action Required
01/13/2025
1436 vertical screws are missing above primary bathroom screw pattern along the rafters edge at demising wall is missing (6-8 inches on center) in the garage Basement rim joist screw pattern along the edges should be every 6-8 inches on center 1438 Screw pattern along the rafters edge at demising wall is missing (6-8 inches on center) in the garage Basement rim joist screw pattern along edges should be every 6-8 inches on center This is a partial rated assembly inspection only
Gas Service Inspection - Residential Failed 1/13/2025 1/13/2025 01/13/2025
Miscellaneous Correction
Corrective Action Required
01/13/2025
Gas failed on both sides because of no pressure in the system at the time of inspection
All Rough Inspection - Residential Failed 1/13/2025 1/13/2025 01/13/2025
Miscellaneous Correction
Corrective Action Required
01/13/2025
Basement of 1436 is not fire blocked Structure is not ready for inspection This is not a complete list
Erosion Control Inspection Residential Partial 1/16/2025 01/16/2025
Miscellaneous Correction
Resolved
01/16/2025
Gravel from the street to the foundation has been covered with dirt from dirt work being done. Restore as soon as possible Full erosion control measures must be in place and properly maintained until CofO
Miscellaneous Correction
Informational
01/16/2025
Erosion control is in compliance at the time of inspection
Gas Service Inspection - Residential Failed 1/16/2025 1/16/2025 01/16/2025
Miscellaneous Correction
Resolved
01/16/2025
Gas failed on both sides because of no pressure in the system at the time of inspection
Miscellaneous Correction
Corrective Action Required
01/16/2025
1436 - gas pressure gauge goes up to 200PSI - replace gas gauge with a pressure limit no more than 35 PSI 1438 gas passed
All Rough Inspection - Residential Failed 1/16/2025 1/16/2025 01/16/2025
Miscellaneous Correction
Resolved
01/16/2025
Basement of 1436 is not fire blocked Structure is not ready for inspection This is not a complete list
Miscellaneous Correction
Corrective Action Required
01/16/2025
1436 Garage anchor bolts need to be located within the middle 1/3 of bottom plate Anchor bolt is not installed at the garage south side PFH Sister king studs in the garage that have been over notched by 50 percent at the bottom plate for anchor bolts Brace cantilevered roof purlins above kitchen and kitchen/entry hall Bathroom 2 at double LVL’s calls for 3 2x4’s for vertical support Double LVL in kitchen by refrigerator needs to be supported by 4 2x4 studs, only 3 are installed Seal return air in stud space in bedroom 3 Install BOCA plates for water supply lines at ceiling/wallof bathroom 3 Install BOCA plate in bathroom 3 at ceiling/wallfor plumbing waste line Install BOCA plate in bedroom 4 to bathroom 3 at ceiling/wall for plumbing waste line BOCA plates are required in wall of bedroom 4 to bathroom 3 for water lines nail plates are not acceptable Support metal gas line in basement game room every 10 feet on center Gas pressure gauge goes up to 200 PSI. Replace with a pressure gauge up to 30PSI 1438 Garage North PFH needs to be located in the middle 1/3 of bottom plate Garage North side PFH strap needs to extend to fasten to both top plates Garage anchor bolts need to be located in the middle 1/3 of bottom plate Support the 2x6 cantilevered rafter purlin above the garage north side about 4 foot from the demising wall Support double LVL’s with three studs in bathroom 2/hallway Double LVL in kitchen above refrigerator needs to be vertically supported by 4 2x4’s Support cantilevered purlins above kitchen and kitchen/entry hallway Support gas line above game room every 10 foot on center Air supply duct in game room has a no supporting bracket because of it being damaged BOCA plates need to be installed instead of nail plates for water lines in bedroom 4/bathroom3 at wall to ceiling Cold water supply line is running in the air supply line line in bedroom 4/bathroom3 Water line from bathroom 3 is out of the stud cavity and inside bedroom 4
Rated Assembly Inspection Partial 1/16/2025 1/16/2025 01/16/2025
Miscellaneous Correction
Resolved
01/16/2025
1436 vertical screws are missing above primary bathroom screw pattern along the rafters edge at demising wall is missing (6-8 inches on center) in the garage Basement rim joist screw pattern along the edges should be every 6-8 inches on center 1438 Screw pattern along the rafters edge at demising wall is missing (6-8 inches on center) in the garage Basement rim joist screw pattern along edges should be every 6-8 inches on center This is a partial rated assembly inspection only
Miscellaneous Correction
Informational
01/16/2025
Both units - Above ceiling and basement rim joist passed and is okay to cover This is a partial pass only
All Rough Inspection - Residential Passed 1/22/2025 1/22/2025 01/22/2025
Miscellaneous Correction
Resolved
01/22/2025
1436 Garage anchor bolts need to be located within the middle 1/3 of bottom plate Anchor bolt is not installed at the garage south side PFH Sister king studs in the garage that have been over notched by 50 percent at the bottom plate for anchor bolts Brace cantilevered roof purlins above kitchen and kitchen/entry hall Bathroom 2 at double LVL’s calls for 3 2x4’s for vertical support Double LVL in kitchen by refrigerator needs to be supported by 4 2x4 studs, only 3 are installed Seal return air in stud space in bedroom 3 Install BOCA plates for water supply lines at ceiling/wallof bathroom 3 Install BOCA plate in bathroom 3 at ceiling/wallfor plumbing waste line Install BOCA plate in bedroom 4 to bathroom 3 at ceiling/wall for plumbing waste line BOCA plates are required in wall of bedroom 4 to bathroom 3 for water lines nail plates are not acceptable Support metal gas line in basement game room every 10 feet on center Gas pressure gauge goes up to 200 PSI. Replace with a pressure gauge up to 30PSI 1438 Garage North PFH needs to be located in the middle 1/3 of bottom plate Garage North side PFH strap needs to extend to fasten to both top plates Garage anchor bolts need to be located in the middle 1/3 of bottom plate Support the 2x6 cantilevered rafter purlin above the garage north side about 4 foot from the demising wall Support double LVL’s with three studs in bathroom 2/hallway Double LVL in kitchen above refrigerator needs to be vertically supported by 4 2x4’s Support cantilevered purlins above kitchen and kitchen/entry hallway Support gas line above game room every 10 foot on center Air supply duct in game room has a no supporting bracket because of it being damaged BOCA plates need to be installed instead of nail plates for water lines in bedroom 4/bathroom3 at wall to ceiling Cold water supply line is running in the air supply line line in bedroom 4/bathroom3 Water line from bathroom 3 is out of the stud cavity and inside bedroom 4
Gas Service Inspection - Residential Failed 1/22/2025 1/22/2025 01/22/2025
Miscellaneous Correction
Resolved
01/22/2025
1436 - gas pressure gauge goes up to 200PSI - replace gas gauge with a pressure limit no more than 35 PSI 1438 gas passed
Miscellaneous Correction
Corrective Action Required
01/22/2025
1436 - gas pressure read 1 PSI at time of inspection 1438 gas passed
Gas Service Inspection - Residential Passed 1/23/2025 1/23/2025 01/23/2025
Miscellaneous Correction
Resolved
01/23/2025
1436 - gas pressure read 1 PSI at time of inspection 1438 gas passed
Rated Assembly Inspection Passed 2/4/2025 2/4/2025 02/04/2025
Miscellaneous Correction
Resolved
02/04/2025
Both units - Above ceiling and basement rim joist passed and is okay to cover This is a partial pass only
Driveway Inspection Passed 3/24/2025 3/24/2025 04/01/2025
Misc
Informational
03/24/2025
3-24-25 BR Driveway is formed up with aggerate is placed and compacted. Ready for concrete. 4-1-25 BR Driveway is constructed to LS specification.
Sidewalk Inspection Passed 4/22/2025 4/22/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specifications.
Sidewalk Inspection Passed 4/24/2025 4/24/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specification.
Documents & Images
Date Uploaded File Type Document Name
06/04/2024 Application - Lot 52
06/04/2024 Tax Form - Lot 52
06/11/2024 Permit Codes Residential Plan Review
06/27/2024 Permit Codes Residential Plan Review
06/28/2024 Plot Plan APPROVED PLOT PLAN
06/28/2024 Approved Plans APPROVED PLANS
06/28/2024 Permit Codes Residential Plan Review
07/11/2024 Permit DS Building Permit
07/11/2024 Receipt Receipt for transaction: 2024-005743
09/10/2024 Letter INSPECTION SUMMARY
09/26/2024 Approved Plans 9-26-24 APPROVED PLAN
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/23/2024 2024_10_22_1436-38 SW Winthrop Terrace_Gslab_Report_Sealed
10/24/2024 Letter INSPECTION SUMMARY
01/13/2025 Letter INSPECTION SUMMARY
01/13/2025 Letter INSPECTION SUMMARY
01/13/2025 Letter INSPECTION SUMMARY
01/13/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
04/01/2025 Letter INSPECTION SUMMARY
04/01/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
05/06/2025 As Grade Plot Plan - Lot 52
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home