Summary
PRRES20242647
Building Permit - Residential
Certificate of Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO. ROOF TRUSSES.
05/23/2024
06/06/2024
11/27/2024
03/11/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/06/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/06/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/06/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/06/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/06/2024
9110078-Valuation Fee New Single Family $1,351.70 $1,351.70 Paid 06/06/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/12/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/17/2024 07/17/2024
Sewer Service Inspection - R Passed 7/17/2024 7/17/2024 07/17/2024
Underslab Plumbing Inspection - Residential Failed 7/25/2024 7/25/2024 07/25/2024
Misc
Corrective Action Required
07/25/2024
Requested inspection denied due to lack of erosion control
Erosion Control Inspection Residential Failed 7/25/2024 07/25/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/25/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. MAINTAIN GRAVEL FILTER
Underslab Plumbing Inspection - Residential Passed 7/29/2024 7/29/2024 07/29/2024
Misc
Resolved
07/29/2024
Requested inspection denied due to lack of erosion control
Water Service Inspection - R Passed 7/31/2024 07/31/2024
Piers/Caissons Inspection - Residential Not Ready 9/19/2024 9/19/2024 09/19/2024
Misc
Corrective Action Required
09/19/2024
Piers not correct size
Piers/Caissons Inspection - Residential Passed 9/26/2024 9/26/2024 09/26/2024
Misc
Resolved
09/26/2024
Piers not correct size
All Rough Inspection - Residential Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
-Lib in garage not installed to plans -seal top plate penetration N bath one wall -uncover covered patio for inspection -fire block kitchen/ bath 2 wall to ceiling space -bed 2 nail lib -truss lateral bracing missing in multiple areas throughout -fire block N rec room wall to ceiling space at furr down near window -fire block W Rec room wall into furr down -
Electrical Service Inspection Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
Bond gas line
Gas Service Inspection - Residential Passed 10/2/2024 10/02/2024
All Rough Inspection - Residential Failed 10/7/2024 10/7/2024 10/07/2024
Misc
Corrective Action Required
10/02/2024
-seal top plate penetration N bath one wall -fire block kitchen/ bath 2 wall to ceiling space(seal penetrations) -truss lateral bracing missing in multiple areas throughout (B4, check others)
All Rough Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Misc
Resolved
10/11/2024
-seal top plate penetration N bath one wall -fire block kitchen/ bath 2 wall to ceiling space(seal penetrations) -truss lateral bracing missing in multiple areas throughout (B4, check others)
Driveway Inspection Partial 10/31/2024 10/31/2024 10/31/2024
Misc
Informational
10/31/2024
10-31-24 Dustin A, Dw is formed and compacted, Approved to pour
Sidewalk Inspection Partial 11/1/2024 11/1/2024 11/01/2024
Misc
Informational
11/01/2024
11-1-24 Dustin A, SW in front and side of house is compacted and formed. Slopes are in compliance. Approved to pour
Electrical Service Inspection Passed 11/6/2024 11/6/2024 11/06/2024
Misc
Resolved
11/06/2024
Bond gas line
Driveway Inspection Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
10/31/2024
10-31-24 Dustin A, Dw is formed and compacted, Approved to pour 11-12-24 Dustin A, Dw is poured to city specs and slopes are in compliance .Pass
Sidewalk Inspection Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/01/2024
11-1-24 Dustin A, SW in front and side of house is compacted and formed. Slopes are in compliance. Approved to pour 11-12-24 Dustin A, SW is poured and slopes are in compliance Expansion joint missed on 3 spots, Approved by RH. Pass
Occupancy Inspection - Codes Residential Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Corrective Action Required
12/10/2024
-final grade and sod -install gutters -splash blocks and sump pump discharge to extend 36” from foundation -outlet above fireplace needs box extender -refrigerator circuit to be AFCI protected -install missing light fixture in basement bedroom
Occupancy Inspection - Codes Residential Ready for Temp CO 12/12/2024 12/12/2024 12/12/2024
Misc
Corrective Action Required
12/10/2024
-final grade and sod -install gutters -splash blocks and sump pump discharge to extend 36” from foundation
Plot Plan Inspection Passed 3/11/2025 3/11/2025 03/11/2025
Occupancy Inspection - Codes Residential Full C of O 3/11/2025 3/11/2025 03/11/2025
Misc
Resolved
03/11/2025
-final grade and sod -install gutters -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
05/23/2024 HT #194 - PERMIT APP
05/31/2024 Permit Codes Residential Plan Review
06/05/2024 Approved Plans APPROVED PLANS
06/05/2024 Plot Plan APPROVED PLOT PLAN
06/05/2024 Approved Plans APPROVED TRUSS PACKAGE
06/05/2024 Approved Plans APPROVED TRUSS LAYOUT
06/05/2024 Permit Codes Residential Plan Review
06/06/2024 Permit DS Building Permit
06/06/2024 Receipt Receipt for transaction:2024-004435
06/25/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/12/2024 Receipt Receipt for transaction:2024-009474
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction:2025-001435
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter Field Certificate of Occupancy
03/11/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home