Summary
PRRES20242530
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSSES STOP WORK ORDER generated on 07/03/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/17/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 12/13/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 12/23/2024 12:00 AM by username 'Mitchell Schwarz'.
05/17/2024
05/24/2024
04/09/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/24/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/24/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/24/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 05/24/2024
Water Meter Fee $680.46 $680.46 Paid 05/24/2024
Valuation Fee New Single Family $2,063.03 $2,063.03 Paid 05/24/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/27/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/1/2024 07/01/2024
Erosion Control Inspection Residential Failed - Stop Work 7/3/2024 7/3/2024 07/03/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. REPAIR ALL DOWN SILT FENCE Still not in compliance stop work issued 07/03/24
Erosion Control Inspection Residential Partial 7/17/2024 7/17/2024 07/17/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. REPAIR ALL DOWN SILT FENCE Still not in compliance stop work issued 07/03/24
Misc
Informational
07/17/2024
07/17/24-Erosion control in compliance at time of inspection
Sewer Service Inspection - R Passed 7/17/2024 7/17/2024 07/17/2024
Water Service Inspection - R Passed 7/17/2024 7/17/2024 07/17/2024
Underslab Plumbing Inspection - Residential Passed 7/29/2024 7/29/2024 07/29/2024
Erosion Control Inspection Residential Partial 8/15/2024 8/15/2024 08/15/2024
Misc
Informational
07/17/2024
07/17/24-Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-15-24 Dustin A, clean up mud and gravel off of street
All Rough Inspection - Residential Failed 8/16/2024 8/16/2024 08/16/2024
Miscellaneous Correction
Corrective Action Required
08/16/2024
8/16/24 -Inspection denied due to deficient erosion control. See failed erosion control inspection on 8/15/24
Erosion Control Inspection Residential Partial 8/19/2024 8/19/2024 08/19/2024
Misc
Informational
08/15/2024
07/17/24-Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-15-24 Dustin A, clean up mud and gravel off of street 8-19-24 Dustin A street has been cleaned
All Rough Inspection - Residential Failed 8/22/2024 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
8/16/24 -Inspection denied due to deficient erosion control. See failed erosion control inspection on 8/15/24
Misc
Corrective Action Required
08/22/2024
Portal inspection only Plate breaks to occur in the middle 24” of the portal leg
All Rough Inspection - Residential Partial 9/4/2024 9/4/2024 09/04/2024
Misc
Resolved
09/04/2024
Portal inspection only Plate breaks to occur in the middle 24” of the portal leg
Misc
Informational
09/04/2024
Portal frame inspection only. Okay to cover
Electrical Service Inspection Passed 10/17/2024 10/17/2024 10/17/2024
All Rough Inspection - Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Resolved
10/17/2024
Portal frame inspection only. Okay to cover
Misc
Corrective Action Required
10/17/2024
-address studs over notched at anchor bolts in garage -missing attic access above 3rd car garage -secure se cable within 12” of disconnect -missing lib throughout -fire lock garage rear wall to ceiling space -attach bath vents -seal dead space at bedroom 5 -strap top plate where over board at rear slider dwv -complete fireplace install -nail all exterior wall corners to plans -address linked bath vent for primary bath -trap top plate where lapped less than 24” see bed 3 -nail all truss hangers 2nd floor -missing lateral bracing for trusses -complete hvac above rec room -seal all penetrations in vertical to horizontal fire blocking -Complete bath vent in basement -frame bed 6 to plans -missing smoke /co outside bed 6
All Rough Inspection - Residential Not Ready 10/21/2024 10/21/2024 10/21/2024
Misc
Corrective Action Required
10/17/2024
-missing lib throughout -fire block garage rear wall to ceiling space(see penetrations) -Address joist cut and landing on hvac chase above pantry. -address plumbing above pantry not complete -address all low voltage penetrations added since last inspection -attach bath vents -strap top plate where -complete fireplace install -nail all exterior wall corners to plans -strap top plate where lapped less than 24” see bed 3 -missing lateral bracing for trusses -complete hvac above rec room -seal all penetrations in vertical to horizontal fire blocking -missing smoke /co outside bed 6
All Rough Inspection - Residential Not Ready 10/25/2024 10/25/2024 10/25/2024
Misc
Corrective Action Required
10/21/2024
-Address joist cut and landing on hvac chase above pantry. (Provide hangers, hvac chase wall not load bearing) -address plumbing above pantry not complete (not done) -address all low voltage penetrations added since last inspection (see garage entry) -complete fireplace install -nail all exterior wall corners to plans -strap top plate where lapped less than 24” see bed 3 -missing lateral bracing for trusses -complete hvac above rec room -seal all penetrations in vertical to horizontal fire blocking -missing smoke /co outside bed 6
Erosion Control Inspection Residential Partial 7/1/2024 7/1/2024 11/05/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
11/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. REPAIR ALL DOWN SILT FENCE
Gas Service Inspection - Residential Passed 11/5/2024 11/5/2024 11/05/2024
All Rough Inspection - Residential Passed 11/5/2024 11/5/2024 11/05/2024
Misc
Resolved
11/05/2024
-Address joist cut and landing on hvac chase above pantry. (Provide hangers, hvac chase wall not load bearing) -address plumbing above pantry not complete (not done) -address all low voltage penetrations added since last inspection (see garage entry) -complete fireplace install -nail all exterior wall corners to plans -strap top plate where lapped less than 24” see bed 3 -missing lateral bracing for trusses -complete hvac above rec room -seal all penetrations in vertical to horizontal fire blocking -missing smoke /co outside bed 6
Sidewalk Inspection Partial 12/4/2024 12/4/2024 12/04/2024
Misc
Informational
12/04/2024
12-4-24 Dustin A, sw is formed and compacted. Slopes are in compliance. Approved to pour
Driveway Inspection Partial 12/4/2024 12/4/2024 12/04/2024
Misc
Informational
12/04/2024
12-4-24 Dustin A, Dw is formed and compacted. Approved to pour
Sidewalk Inspection Partial 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
12/04/2024
12-4-24 Dustin A, sw is formed and compacted. Slopes are in compliance. Approved to pour 12-11-24 Jamie S, SW is compliant with city standards. Slopes are in compliance. Cannot pass until forms are taken down.
Driveway Inspection Partial 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
12/04/2024
12-4-24 Dustin A, Dw is formed and compacted. Approved to pour 12-11-24 Jamie S, DW is sloped to city standards. Cannot pass until forms are removed.
Erosion Control Inspection Residential Failed 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
08/19/2024
07/17/24-Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/19/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-15-24 Dustin A, clean up mud and gravel off of street 8-19-24 Dustin A street has been cleaned
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/11/2024
Jamie, S, 12-11-24 No Erosion control on site. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 12/13/2024 12/13/2024 12/13/2024
Misc
Informational
12/11/2024
07/17/24-Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-15-24 Dustin A, clean up mud and gravel off of street 8-19-24 Dustin A street has been cleaned
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/11/2024
Jamie, S, 12-11-24 No Erosion control on site. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 12-13-24 Dustin A, Erosion control has not been corrected Fail
Erosion Control Inspection Residential Partial 12/23/2024 12/23/2024 12/23/2024
Misc
Informational
12/13/2024
12/23/24-Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Resolved
12/23/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-15-24 Dustin A, clean up mud and gravel off of street 8-19-24 Dustin A street has been cleaned
DCM3 ESC REQUIRED 2 DAY
Resolved
12/23/2024
Jamie, S, 12-11-24 No Erosion control on site. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 12-13-24 Dustin A, Erosion control has not been corrected Fail
Plot Plan Inspection Passed 12/24/2024 12/24/2024
Erosion Control Inspection Residential Partial 12/24/2024 12/24/2024
Misc
Informational
12/23/2024
12/23/24-Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 12/24/2024 12/24/2024 12/24/2024
Misc
Corrective Action Required
12/24/2024
- pending sidewalk inspection - pending driveway inspection - Uncover water meter, will check when located - Final grading and sod - Provide splash pads at downspouts away from foundation 36” - A/C whip short, must be attached within 12” of disconnect - Outlet in single bay garage to be, GFCI protected OR a single with label non- GFCI - Steps to patio not within the 3/8” variance allowed - Smoke alarm in basement bedroom not interconnected with other alarms
Sidewalk Inspection Passed 12/24/2024 12/24/2024 12/24/2024
Misc
Informational
12/11/2024
12-4-24 Dustin A, sw is formed and compacted. Slopes are in compliance. Approved to pour 12-11-24 Jamie S, SW is compliant with city standards. Slopes are in compliance. Cannot pass until forms are taken down. 12-24-24 Jamie S, Forms have been taken down. Passed
Driveway Inspection Passed 12/24/2024 12/24/2024 12/24/2024
Misc
Informational
12/11/2024
12-4-24 Dustin A, Dw is formed and compacted. Approved to pour 12-11-24 Jamie S, DW is sloped to city standards. Cannot pass until forms are removed. 12-24-24 Jamie S, Forms have been pulled. Passed.
Occupancy Inspection - Codes Residential Ready for Temp CO 12/27/2024 12/27/2024 12/27/2024
Misc
Corrective Action Required
12/24/2024
- Uncover water meter, will check when located ensure 14”-18” from top of meter to well lid ring - Final grading and sod - Provide splash pads at downspouts away from foundation 36” - Steps to patio not within the 3/8” variance allowed
Erosion Control Inspection Residential Failed 1/2/2025 1/2/2025 01/02/2025
Misc
Informational
12/24/2024
12/23/24-Erosion control in compliance at time of inspection 1-2-25 Dustin A, SW has dirt piled on it . Needs to be cleaned off
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/02/2025
1-2-25 Dustin A, SW has dirt piled on it . Needs to be cleaned off. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 04/09/2025
Misc
Resolved
04/09/2025
12/23/24-Erosion control in compliance at time of inspection 1-2-25 Dustin A, SW has dirt piled on it . Needs to be cleaned off
DCM3 ESC REQUIRED 2 DAY
Resolved
04/09/2025
1-2-25 Dustin A, SW has dirt piled on it . Needs to be cleaned off. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 4/9/2025 4/9/2025 04/09/2025
Misc
Resolved
04/09/2025
- Uncover water meter, will check when located ensure 14”-18” from top of meter to well lid ring - Final grading and sod - Provide splash pads at downspouts away from foundation 36” - Steps to patio not within the 3/8” variance allowed
Documents & Images
Date Uploaded File Type Document Name
05/17/2024 H4 #124 - ENGINEERED PLANS
05/17/2024 Application Form H4 #124 - PERMIT APP
05/17/2024 H4 #124 - PLOT PLAN
05/17/2024 H4 #124 - TRUSS DETAILS
05/17/2024 H4 #124 - TRUSS LAYOUT
05/20/2024 Approved Plans APPROVED PLANS
05/20/2024 Plot Plan APPROVED PLOT PLAN
05/20/2024 Approved Plans APPROVED TRUSS LAYOUT
05/20/2024 Approved Plans APPROVED TRUSS PACKAGE
05/23/2024 Permit Codes Residential Plan Review
05/24/2024 Permit DS Building Permit
05/24/2024 Receipt Receipt for transaction:2024-003953
07/01/2024 3RD Party Insp Report M L Crose 3236 SW Arbor Tree Dr LSMO Clayton Properties Permit 2024-2530 3rd Party Footing Inspection Report 6-26-24
07/01/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter Stop Work Order
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/21/2024 Letter INSPECTION SUMMARY
10/25/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/12/2024 Receipt Receipt for transaction:2024-009491
12/13/2024 Letter Stop Work Order
12/13/2024 Letter Stop Work Order
12/23/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/27/2024 Receipt Receipt for transaction:2024-009667
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/16/2025 HT #124 - TCO Extension App 1_16_25
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001538
04/09/2025 Letter INSPECTION SUMMARY
04/09/2025 Letter Field Certificate of Occupancy
04/09/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home