Permit Application Status

PRRES20242467


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242467
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
05/15/2024
05/17/2024
02/03/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/17/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/17/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/17/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 05/17/2024
Water Meter Fee $680.46 $680.46 Paid 05/17/2024
Valuation Fee New Single Family $1,459.08 $1,459.08 Paid 05/17/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/09/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/08/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/18/2024 7/18/2024 07/18/2024
Footing Inspection - Residential Passed 7/18/2024 07/18/2024
Miscellaneous Correction
Informational
07/18/2024
Footing was passed by a third party on 06/19/24. No exterior piers were mentioned in footing inspection
Erosion Control Inspection Residential Partial 7/18/2024 07/18/2024
Miscellaneous Correction
Informational
07/18/2024
Erosion control measures are in place and must be maintained until CofO
Water Service Inspection - R Passed 7/19/2024 7/19/2024 07/19/2024
Underslab Plumbing Inspection - Residential Passed 7/29/2024 07/29/2024
Erosion Control Inspection Residential Failed 8/16/2024 8/16/2024 08/16/2024
Miscellaneous Correction
Informational
07/18/2024
Erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/16/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean loose trash and debris from site
All Rough Inspection - Residential Not Ready 8/16/2024 8/16/2024 08/16/2024
Miscellaneous Correction
Corrective Action Required
08/16/2024
8/16/24 Portal Frame inspection -Not ready. Nail all framing members per code at Portal frame
All Rough Inspection - Residential Partial 8/22/2024 8/22/2024 08/22/2024
Miscellaneous Correction
Resolved
08/22/2024
8/16/24 Portal Frame inspection -Not ready. Nail all framing members per code at Portal frame
Misc
Informational
08/22/2024
Garage Portal frame inspection only. Okay to cover
All Rough Inspection - Residential Not Ready 9/23/2024 9/23/2024 09/23/2024
Misc
Informational
08/22/2024
Garage Portal frame inspection only. Okay to cover
Misc
Corrective Action Required
09/23/2024
HOUSE NOT READY FOR INSPECTION COMPLETE ALL ITEMS BEFORE CALLING FOR RE INSPECTION . (Garage only inspected) -missing lib through out -missing nails in all hangers above garage -address over notched exterior wall stud notched for anchor bolt(NW CORNER GARAGE) -anchor bolt at PFH to Be in the middle 1/3 of sill plate -missing anchor bolts within 12” of plate ends but not closer than 7x the diameter of the bolt -nail plate under PFH header to code/plans -missing truss hold downs throughout -seal all top plate penetrations in garage above panel -missing attic access above garage single car area -complete framing and address missing stud at owners entry return air -nail trusses together to plans -missing lateral bracing in multiple trusses in multiple places throughout
All Rough Inspection - Residential Failed 9/26/2024 9/26/2024 09/26/2024
Misc
Informational
09/23/2024
Garage Portal frame inspection only. Okay to cover
Misc
Corrective Action Required
09/23/2024
-missing nails in all hangers above garage -address over notched exterior wall stud notched for anchor bolt(NW CORNER GARAGE) -anchor bolt at PFH to Be in the middle 1/3 of sill plate -nail plate under PFH header to code/plans -seal all top plate penetrations in garage above panel -Provide stud shoe at over bored studs in kitchen/ bathroom wall -Anchor all steel columnn in basement
All Rough Inspection - Residential Failed 10/1/2024 10/1/2024 10/01/2024
Misc
Informational
09/26/2024
Garage Portal frame inspection only. Okay to cover
Misc
Corrective Action Required
09/26/2024
-Provide stud shoe at over bored studs in kitchen/ bathroom wall
All Rough Inspection - Residential Passed 10/2/2024 10/2/2024 10/02/2024
Misc
Resolved
10/02/2024
Garage Portal frame inspection only. Okay to cover
Misc
Resolved
10/02/2024
-Provide stud shoe at over bored studs in kitchen/ bathroom wall
Gas Service Inspection - Residential Passed 10/2/2024 10/02/2024
Electrical Service Inspection Passed 10/4/2024 10/4/2024 10/04/2024
Driveway Inspection Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/12/2024
11-12-24 Dustin A, dw is formed and compacted. Approved to pour.
Erosion Control Inspection Residential Failed 11/19/2024 11/19/2024 11/19/2024
Miscellaneous Correction
Informational
08/16/2024
Erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/16/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean loose trash and debris from site
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/19/2024
11-19-24 Dustin A, Restroom needs be removed from street. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 11/22/2024 11/22/2024 11/22/2024
Miscellaneous Correction
Informational
11/19/2024
Erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/19/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean loose trash and debris from site
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/19/2024
11-19-24 Dustin A, Restroom needs be removed from street. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-22-24 Dustin A, Restroom died
Driveway Inspection Passed 11/22/2024 11/22/2024 11/22/2024
Misc
Informational
11/12/2024
11-12-24 Dustin A, dw is formed and compacted. Approved to pour. 11-22-24 Dustin A, DW is poured to city specs. Passed
Occupancy Inspection - Codes Residential Not Ready 12/3/2024 12/3/2024 12/03/2024
Misc
Corrective Action Required
12/03/2024
No erosion control in place. Inspection denied.
Occupancy Inspection - Codes Residential Failed 12/5/2024 12/5/2024 12/05/2024
Misc
Resolved
12/05/2024
No erosion control in place. Inspection denied.
Misc
Corrective Action Required
12/05/2024
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing lid -ensure water meter pit top is flush with grade and meter top to well lid ring is 14”-18” -outlets under kitchen sing to be gfci protected -repair hole in drywall near stairs in garage
Occupancy Inspection - Codes Residential Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Corrective Action Required
12/05/2024
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing lid -ensure water meter pit top is flush with grade and meter top to well lid ring is 14”-18” -outlets under kitchen sink to be gfci protected
Occupancy Inspection - Codes Residential Ready for Temp CO 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/06/2024
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing lid -ensure water meter pit top is flush with grade and meter top to well lid ring is 14”-18”
Occupancy Inspection - Codes Residential Ready for Temp CO 1/8/2025 01/08/2025
Misc
Corrective Action Required
12/09/2024
TCO extension granted for an additional 30 day Mitchell Schwarz 01/08/2025 2:19 PM -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing lid -ensure water meter pit top is flush with grade and meter top to well lid ring is 14”-18”
Plot Plan Inspection Passed 2/3/2025 02/03/2025
Erosion Control Inspection Residential Passed 2/3/2025 02/03/2025
Miscellaneous Correction
Resolved
02/03/2025
Erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/03/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean loose trash and debris from site
DCM3 ESC REQUIRED 2 DAY
Resolved
02/03/2025
11-19-24 Dustin A, Restroom needs be removed from street. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-22-24 Dustin A, Restroom died
Occupancy Inspection - Codes Residential Full C of O 2/3/2025 2/3/2025 02/03/2025
Misc
Resolved
02/03/2025
TCO extension granted for an additional 30 day Mitchell Schwarz 01/08/2025 2:19 PM -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -address water meter pit missing lid -ensure water meter pit top is flush with grade and meter top to well lid ring is 14”-18”
Documents & Images
Date Uploaded File Type Document Name
05/15/2024 H4 #116 - ENGINEERED PLANS
05/15/2024 H4 #116 - PERMIT APP
05/15/2024 H4 #116 - PLOT PLAN
05/15/2024 H4 #116 - TRUSS LAYOUT
05/15/2024 H4 #1116 - TRUSS DETAILS
05/16/2024 Approved Plans APPROVED PLANS
05/16/2024 Plot Plan APPROVED PLOT PLAN
05/16/2024 Approved Plans APPROVED TRUSS LAYOUT
05/16/2024 Approved Plans APPROVED TRUSS PACKAGE
05/16/2024 Permit Codes Residential Plan Review
05/17/2024 Permit DS Building Permit
05/17/2024 Receipt Receipt for transaction:2024-003614
06/20/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/04/2024 Receipt Receipt for transaction:2024-009314
12/05/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/09/2024 Receipt Receipt for transaction:2024-009394
01/08/2025 Application Form HT #116 - TCO Extension Form 1_8_25
01/08/2025 Letter INSPECTION SUMMARY
01/08/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/08/2025 Receipt Receipt for transaction:2025-000107
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter Codes Final Certificate of Occupancy
02/03/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home