Permit Application Status

PRRES20242193


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242193
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK.
05/01/2024
05/09/2024
11/03/2024
02/14/2025
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
Zack Bryant, Address:200 NW Commerce CT, Phone:(816) 267-7073  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
zbryant@sabhomes.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/09/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/09/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/09/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/09/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/09/2024
9110078-Valuation Fee New Single Family $1,450.57 $1,450.57 Paid 05/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 5/28/2024 5/28/2024 05/28/2024
Sewer Service Inspection - R Passed 5/28/2024 5/28/2024 05/28/2024
Water Service Inspection - R Passed 5/30/2024 05/30/2024
Piers/Caissons Inspection - Residential Passed 6/13/2024 6/13/2024 06/13/2024
All Rough Inspection - Residential Failed 7/24/2024 7/24/2024 07/24/2024
Misc
Corrective Action Required
07/24/2024
- portal frame approved - Deck roof does not have post installed
Erosion Control Inspection Residential Failed 7/24/2024 07/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/24/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT FRONT OF LOT
Erosion Control Inspection Residential Failed 9/30/2024 09/30/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/30/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT FRONT OF LOT
Misc
Corrective Action Required
09/30/2024
- TRIM TALL VEGETATION ON LOT
Electrical Service Inspection Passed 9/30/2024 09/30/2024
Gas Service Inspection - Residential Passed 9/30/2024 09/30/2024
All Rough Inspection - Residential Failed 9/30/2024 9/30/2024 09/30/2024
Misc
Resolved
09/30/2024
- portal frame approved - Deck roof does not have post installed
Misc
Corrective Action Required
09/30/2024
- Address over notched stud at garage door west side - Provide hangers for joists over 4’ in master closet - Fire block electrical penetrations in plenum space behind fireplace - Strap top plate at dining/ great room were not tied in with height change - Minimum of 3 studs required at alll exterior corners and missing sill and 1 top plate ( Southern corner of basement) - Shim exterior wall studs next to stairs ( cut short , no bearing)
Footing Inspection - Residential Passed 10/2/2024 10/02/2024
All Rough Inspection - Residential Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
09/30/2024
No access inspection denied-10/02/24 - Address over notched stud at garage door west side - Provide hangers for joists over 4’ in master closet - Fire block electrical penetrations in plenum space behind fireplace - Strap top plate at dining/ great room were not tied in with height change - Minimum of 3 studs required at alll exterior corners and missing sill and 1 top plate ( Southern corner of basement) - Shim exterior wall studs next to stairs ( cut short , no bearing)
All Rough Inspection - Residential Failed 10/3/2024 10/3/2024 10/03/2024
Misc
Corrective Action Required
10/02/2024
- Strap top plate at dining/ great room were not tied in with height change(strap top plate of dinging room wall to great room wall . Exterior wall to exterior wall)
All Rough Inspection - Residential Passed 10/7/2024 10/7/2024 10/07/2024
Misc
Resolved
10/07/2024
- Strap top plate at dining/ great room were not tied in with height change(strap top plate of dinging room wall to great room wall . Exterior wall to exterior wall)
Driveway Inspection Failed 10/28/2024 10/28/2024 10/28/2024
Misc
Corrective Action Required
10/28/2024
10-28-24 Dustin A, Dw has standing water in it. Cannot pour , must recall when water is gone and dried out . FAILED.
Sidewalk Inspection Failed 10/28/2024 10/28/2024 10/28/2024
Misc
Corrective Action Required
10/28/2024
10-28-24 Dustin A, sw has standing water , cannot pour till it has been dried out, must recall. FAILED
Driveway Inspection Partial 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/28/2024
10-28-24 Dustin A, Dw has standing water in it. Cannot pour , must recall when water is gone and dried out . FAILED. 10-29-24 Dustin A, Water has been removed and recompacted. Approved to pour
Sidewalk Inspection Partial 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/28/2024
10-28-24 Dustin A, sw has standing water , cannot pour till it has been dried out, must recall. FAILED 10-29-24 Dustin A, water is removed , Approved to pour
Driveway Inspection Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Corrective Action Required
10/29/2024
10-28-24 Dustin A, Dw has standing water in it. Cannot pour , must recall when water is gone and dried out . FAILED. 10-29-24 Dustin A, Water has been removed and recompacted. Approved to pour 11-12-24 Dustin A, DW has been poured to city specs and slopes are in compliance. Pass
Sidewalk Inspection Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Corrective Action Required
10/29/2024
10-28-24 Dustin A, sw has standing water , cannot pour till it has been dried out, must recall. FAILED 10-29-24 Dustin A, water is removed , Approved to pour 11-12-24 Dustin A, SW has been poured to city specs and slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Failed 1/21/2025 1/21/2025 01/21/2025
Misc
Corrective Action Required
01/21/2025
-outlets at basement wet bar to be gfci protected -water meter lid frozen shut. Can not confirm 14”-18” from top of meter to well ring lid
Plot Plan Inspection Passed 01/21/2025
Occupancy Inspection - Codes Residential Full C of O 2/14/2025 2/14/2025 02/14/2025
Misc
Resolved
02/14/2025
-outlets at basement wet bar to be gfci protected -water meter lid frozen shut. Can not confirm 14”-18” from top of meter to well ring lid
Erosion Control Inspection Residential Passed 02/14/2025
Misc
Resolved
02/14/2025
- TRIM TALL VEGETATION ON LOT
Documents & Images
Date Uploaded File Type Document Name
05/01/2024 HF104 - Air Combustion
05/01/2024 HF104 - Excise Tax
05/01/2024 HF104 - Permit Application
05/07/2024 Approved Plans APPROVED PLANS
05/07/2024 Permit Codes Residential Plan Review
05/09/2024 Plot Plan APPROVED PLOT PLAN
05/09/2024 Permit Codes Residential Plan Review
05/09/2024 Permit DS Building Permit
05/09/2024 Receipt Receipt for transaction:2024-003187
05/14/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
05/28/2024 Letter INSPECTION SUMMARY
05/28/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
01/09/2025 LOT 104 ASBUILT
01/21/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
02/14/2025 Letter Codes Final Certificate of Occupancy
02/14/2025 Letter INSPECTION SUMMARY
02/14/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home