Permit Application Status

PRRES20242187


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242187
Building Permit - Residential
Certificate of Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - STOP WORK ORDER generated on 10/17/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 11/21/2024 12:00 AM by username 'Kyle Beard'.
05/01/2024
05/07/2024
03/14/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/07/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/07/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/07/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/07/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/07/2024
9110078-Valuation Fee New Single Family $1,520.54 $1,520.54 Paid 05/07/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/02/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/02/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/03/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/20/2024 05/20/2024
Sewer Service Inspection - R Passed 6/4/2024 06/04/2024
Underslab Plumbing Inspection - Residential Failed 6/18/2024 6/18/2024 06/18/2024
Misc
Corrective Action Required
06/18/2024
Provide address and gravel drive for inspection
Erosion Control Inspection Residential Failed 6/18/2024 06/18/2024
DCM5 ESC INSP DENIED
Corrective Action Required
06/18/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Provide address and gravel drive for inspection
Underslab Plumbing Inspection - Residential Passed 6/20/2024 6/20/2024 06/20/2024
Misc
Resolved
06/20/2024
Provide address and gravel drive for inspection
Erosion Control Inspection Residential Partial 6/20/2024 06/20/2024
DCM5 ESC INSP DENIED
Resolved
06/20/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Provide address and gravel drive for inspection
Misc
Corrective Action Required
06/20/2024
Erosion control in compliance at time of inspection.
All Rough Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Misc
Corrective Action Required
07/17/2024
Garage portal frame okay to cover hold downs, not done at covered porch and patio
Water Service Inspection - R Passed 7/19/2024 7/19/2024 07/19/2024
All Rough Inspection - Residential Failed 8/22/2024 8/22/2024 08/22/2024
Misc
Corrective Action Required
07/17/2024
-anchor bolts to be within 12” of plate breaks -fire block garage rear wall into ceiling space -seal all low voltage penetrations -missing multiple truss hangers throughout -nail trusses together to plans (missing nails) -address over notched floor joist near stairs for dwv -support hvac supply vents to code -use approved hangers for csst line -bond gas line
All Rough Inspection - Residential Failed 8/30/2024 8/30/2024 08/30/2024
Misc
Corrective Action Required
08/22/2024
-anchor bolts to be within 12” of plate breaks and ends -block joist space at cantilever -block joist spaces where joist running parallel to foundation walls to code
All Rough Inspection - Residential Passed 9/6/2024 9/6/2024 09/06/2024
Misc
Resolved
09/06/2024
-anchor bolts to be within 12” of plate breaks and ends -block joist space at cantilever -block joist spaces where joist running parallel to foundation walls to code
Gas Service Inspection - Residential Failed 9/16/2024 9/16/2024 09/16/2024
G2417.4 Test pressure measurement
Corrective Action Required
09/16/2024
INSPECTION, TESTING AND PURGING. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure.
Electrical Service Inspection Passed 9/16/2024 9/16/2024 09/16/2024
Erosion Control Inspection Residential Failed 10/4/2024 10/04/2024
Misc
Resolved
10/04/2024
Erosion control in compliance at time of inspection.
Misc
Corrective Action Required
10/04/2024
- REMOVE TRASH AND DEBRIS FROM LOT
Gas Service Inspection - Residential Passed 10/4/2024 10/4/2024 10/04/2024
G2417.4 Test pressure measurement
Resolved
10/04/2024
INSPECTION, TESTING AND PURGING. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure.
Driveway Inspection Partial 10/10/2024 10/10/2024 10/10/2024
Misc
Informational
10/10/2024
10-10-24 Dustin A, dw is formed and compacted. Approved to pour
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
Misc
Corrective Action Required
10/04/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, Straw waddle has been damaged or removed in spots and needs to be fixed. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 10/17/2024 10/17/2024 10/17/2024
Misc
Corrective Action Required
10/14/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, Straw waddle has been damaged or removed in spots and needs to be fixed. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, has not been corrected
Erosion Control Inspection Residential Failed 11/20/2024 11/20/2024 11/20/2024
Misc
Corrective Action Required
10/17/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Resolved
11/20/2024
10-14-24 Dustin A, Straw waddle has been damaged or removed in spots and needs to be fixed. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, has not been corrected
DCM5 ESC INSP DENIED
Corrective Action Required
11/20/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Remove large rocks from the street for proper water drainage to the storm inlet Stop work order will remain in place until street is clear of debris 11/20/2024 KBEARD
Erosion Control Inspection Residential Partial 11/21/2024 11/21/2024
Misc
Resolved
11/21/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM5 ESC INSP DENIED
Resolved
11/21/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Remove large rocks from the street for proper water drainage to the storm inlet Stop work order will remain in place until street is clear of debris 11/20/2024 KBEARD
Miscellaneous Correction
Corrective Action Required
11/21/2024
Miscellaneous Correction
Informational
11/21/2024
Erosion control measures are in place and must be properly maintained until CofO
Piers/Caissons Inspection - Residential Passed 11/22/2024 11/22/2024 11/22/2024
Erosion Control Inspection Residential Failed 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Corrective Action Required
11/21/2024
-Remove loose trash from lot
Miscellaneous Correction
Informational
11/21/2024
Erosion control measures are in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Not Ready 11/26/2024 11/26/2024 11/26/2024
Misc
Corrective Action Required
11/26/2024
Not ready -Complete all open electrical before scheduling inspection
Occupancy Inspection - Codes Residential Failed 11/27/2024 11/27/2024 11/27/2024
Misc
Resolved
11/27/2024
Not ready -Complete all open electrical before scheduling inspection
Miscellaneous Correction
Corrective Action Required
11/27/2024
Seal gaps under chase in garage Garage to house steps need guard rail and handrail installed One garage electrical receptacle needs to be GFCI protected Install anti hammer device at kitchen sink Hood vent is not installed Sod, splash pads and sump pump extension is not installed Driveway final is not completed Plot plan needs to pass Pay $75 fee associated with this permit
Plot Plan Inspection Failed 11/27/2024 11/27/2024
Miscellaneous Correction
Corrective Action Required
11/27/2024
Plot plan could not not completed because final grading was not done
Erosion Control Inspection Residential Partial 11/27/2024 11/27/2024
Miscellaneous Correction
Resolved
11/27/2024
-Remove loose trash from lot
Miscellaneous Correction
Informational
11/26/2024
Erosion control measures are in place and must be properly maintained until CofO
Driveway Inspection Passed 11/27/2024 11/27/2024 11/27/2024
Misc
Informational
10/10/2024
10-10-24 Dustin A, dw is formed and compacted. Approved to pour 11-27-24 Dustin A, dw is poured to city specs, Pass
Occupancy Inspection - Codes Residential Ready for Temp CO 12/2/2024 12/2/2024 12/02/2024
Miscellaneous Correction
Corrective Action Required
11/27/2024
Final grade Sod, splash pads and sump pump extension is not installed Pay all fees
Occupancy Inspection - Codes Residential Failed 1/3/2025 01/03/2025
Miscellaneous Correction
Corrective Action Required
12/02/2024
Final grade Sod, splash pads and sump pump extension is not installed Pay all fees
Occupancy Inspection - Codes Residential Full C of O 3/14/2025 3/14/2025 03/14/2025
Miscellaneous Correction
Resolved
03/14/2025
Final grade Sod, splash pads and sump pump extension is not installed Pay all fees
Documents & Images
Date Uploaded File Type Document Name
05/01/2024 HT #183 - ENGINEERED PLANS
05/01/2024 Application Form HT #183 - PERMIT APP
05/01/2024 HT #183 - PLOT PLAN
05/01/2024 HT #183 - TRUSS DETAILS
05/01/2024 HT #183 - TRUSS LAYOUT
05/02/2024 Approved Plans APPROVED PLANS
05/02/2024 Approved Plans APPROVED PLOT PLAN
05/02/2024 Approved Plans APPROVED TRUSS LAYOUT
05/02/2024 Approved Plans APPROVED TRUSS PACKAGE
05/07/2024 Permit Codes Residential Plan Review
05/07/2024 Permit Codes Residential Plan Review
05/07/2024 Permit DS Building Permit
05/07/2024 Receipt Receipt for transaction:2024-003088
05/17/2024 M L Crose 1613 SW Arborway Terr LSMO Hawthorne Ridge Lot 183 Footing Inspection Report 5-17-24
05/20/2024 Letter INSPECTION SUMMARY
05/24/2024 LOT 183 FINAL 5-23-24
05/28/2024 Plot Plan APPROVED UPDATED PLOT PLAN
06/04/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter Stop Work Order
10/17/2024 Letter Stop Work Order
11/20/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/02/2024 Receipt Receipt for transaction:2024-009238
12/26/2024 HT #183 - TCO Extension 12_26_24
01/03/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/03/2025 Receipt Receipt for transaction:2025-000041
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001513
03/14/2025 Letter Codes Final Certificate of Occupancy
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: