NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES STOP WORK ORDER generated on 04/15/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 04/16/2024 12:00 AM by username 'Mitchell Schwarz'.
03/12/2024
03/18/2024
09/10/2024
03/13/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/18/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/18/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/18/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 03/18/2024
Water Meter Fee $680.46 $680.46 Paid 03/18/2024
Valuation Fee New Single Family $1,805.59 $1,805.59 Paid 03/18/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/11/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/13/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 10/04/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/03/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/03/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/03/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 4/15/2024 4/15/2024 04/15/2024
Footing Inspection - Residential Failed - Stop Work 4/15/2024 04/15/2024
Misc
Corrective Action Required
04/15/2024
Footing poured without inspection
Footing Inspection - Residential Passed 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/15/2024
Footing poured without inspection
Water Service Inspection - R Passed 4/17/2024 4/17/2024 04/17/2024
Underslab Plumbing Inspection - Residential Passed 4/18/2024 4/18/2024 04/18/2024
Erosion Control Inspection Residential Failed 4/18/2024 04/18/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/18/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/18/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 5/15/2024 5/15/2024 05/15/2024
Misc
Informational
05/15/2024
Garage portal frame nailing inspected only.
All Rough Inspection - Residential Failed 6/20/2024 6/21/2024 06/21/2024
Misc
Informational
05/15/2024
Garage portal frame nailing inspected only.
Misc
Corrective Action Required
06/21/2024
-fireblock rear garage wall into furr down hvac chases and multiple other areas -address multiple top plates in garage -furr out for gas line in garage -sister over notched studs for anchor bolts in garage full length -plans call for double 2x10 floor joist above garage -missing nails in hanger at pantry entry -plans call for 3 studs between windows see office -uncover covered front porch walls and ceiling -seal 2nd floor bath dead space to ceiling space -nail All double trusses together -provide proper slope for dwv above bed 4 -naill all exterior wall corner studs to code -missing anchor bolts on stairwell wall -complete hold down at NE wall corner -add blocking under kitchen per plan -bond gas line -nail all exterior wall sheathing to plans
Electrical Service Inspection Failed 6/20/2024 6/21/2024 06/21/2024
Misc
Corrective Action Required
06/21/2024
Bond gas line
Gas Service Inspection - Residential Failed 6/26/2024 6/26/2024 06/26/2024
Misc
Corrective Action Required
06/26/2024
Pressure okay. Bond gas line
All Rough Inspection - Residential Failed 6/26/2024 6/26/2024 06/26/2024
Misc
Resolved
06/26/2024
Garage portal frame nailing inspected only.
Misc
Corrective Action Required
06/21/2024
-fireblock rear garage wall into furr down hvac chases and multiple other areas -address multiple top plates in garage -plans call for double 2x10 floor joist above garage follow through cantilever -missing nails in hanger at pantry entry -uncover covered front porch walls and ceiling -seal 2nd floor bath dead space to ceiling space -provide proper slope for dwv above bed 4 -missing anchor bolts on stairwell wall -complete hold down at NE wall corner -add blocking under kitchen per plan -bond gas line
All Rough Inspection - Residential Failed 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
06/26/2024
-address multiple top plates in garage -plans call for double 2x10 floor joist above garage follow through cantilever -truss screw incorrectly installed -seal 2nd floor bath dead space to ceiling space -missing anchor bolts on stairwell wall -complete hold down at NE wall corner -bond gas line
Gas Service Inspection - Residential Not Ready 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
06/26/2024
Pressure okay. Bond gas line
All Rough Inspection - Residential Failed 7/11/2024 7/11/2024 07/11/2024
Misc
Corrective Action Required
07/10/2024
-address multiple top plates in garage(fix to engineer specifications) -complete hold down at NE wall corner -bond gas line
Gas Service Inspection - Residential Passed 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
Pressure okay. Bond gas line
All Rough Inspection - Residential Passed 7/15/2024 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
-address multiple top plates in garage(fix to engineer specifications) -complete hold down at NE wall corner -bond gas line
Electrical Service Inspection Passed 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
Bond gas line
Erosion Control Inspection Residential Failed 7/15/2024 07/15/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/15/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
07/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/15/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR SILT FENCE
Driveway Inspection Partial 8/2/2024 08/02/2024
Misc
Informational
08/02/2024
8-2-24 Dustin A, Dw is formed and compacted to city specs . Approved to pour
Sidewalk Inspection Partial 8/6/2024 08/06/2024
Misc
Informational
08/06/2024
8-6-24 Dustin A, SW is formed and aggregate is compacted slopes are in compliance . Approved to pour
Driveway Inspection Passed 8/9/2024 8/9/2024 08/08/2024
Misc
Informational
08/02/2024
8-2-24 Dustin A, Dw is formed and compacted to city specs . Approved to pour 8-8-24 Dustin A, DW is poured to city specs. Forms pulled. Passed
Sidewalk Inspection Passed 8/13/2024 8/13/2024 08/13/2024
Misc
Informational
08/06/2024
8-6-24 Dustin A, SW is formed and aggregate is compacted slopes are in compliance . Approved to pour 8-13-24 Dustin A, Sw is poured to city specs and slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Not Ready 9/10/2024 9/10/2024 09/10/2024
Misc
Corrective Action Required
09/10/2024
INSPECTION DENIED -no address posted -erosion control not in compliance
Erosion Control Inspection Residential Failed 9/10/2024 09/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR SILT FENCE
DCM5 ESC INSP DENIED
Corrective Action Required
09/10/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO EROSION CONTROL IN PLACE Erosion control must be in place until sod is installed
Occupancy Inspection - Codes Residential Failed 9/11/2024 9/11/2024 09/11/2024
Misc
Resolved
09/11/2024
INSPECTION DENIED -no address posted -erosion control not in compliance
Misc
Corrective Action Required
09/11/2024
-pay all fees -sod -splash blocks and sump pump discharge to extend 36” from foundation -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Erosion Control Inspection Residential Partial 9/11/2024 9/11/2024 09/11/2024
DCM5 ESC INSP DENIED
Resolved
09/11/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO EROSION CONTROL IN PLACE Erosion control must be in place until sod is installed
Misc
Informational
09/11/2024
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 9/13/2024 9/13/2024 09/13/2024
Misc
Corrective Action Required
09/11/2024
-pay all fees -sod -splash blocks and sump pump discharge to extend 36” from foundation -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Occupancy Inspection - Codes Residential Ready for Temp CO 10/4/2024 10/04/2024
Misc
Corrective Action Required
09/13/2024
*TCO EXTENSION LETTER UPLOADED, APPROVED FOR 30 DAY EXTENSION* -pay all fees -sod -splash blocks and sump pump discharge to extend 36” from foundation -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Occupancy Inspection - Codes Residential Failed 12/2/2024 12/02/2024
Misc
Corrective Action Required
10/04/2024
PERMIT IN NOV STATUS. PLEASE ADDRESS ALL ITEMS AND COMPLETE -pay all fees -sod -splash blocks and sump pump discharge to extend 36” from foundation -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Occupancy Inspection - Codes Residential Failed 1/2/2025 01/02/2025
Misc
Corrective Action Required
12/02/2024
PERMIT IN NOV STATUS. PLEASE ADDRESS ALL ITEMS AND COMPLETE -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Plot Plan Inspection Passed 03/13/2025
Occupancy Inspection - Codes Residential Full C of O 3/13/2025 3/13/2025 03/13/2025
Misc
Resolved
03/13/2025
PERMIT IN NOV STATUS. PLEASE ADDRESS ALL ITEMS AND COMPLETE -bring water meter well to grade (ensure 14”-18” from top of meter to well lid ring) -bring valves tops to grade
Documents & Images
Date Uploaded File Type Document Name
03/12/2024 Permit Codes Residential Plan Review
03/12/2024 Approved Plans APPROVED PLANS
03/12/2024 Approved Plans APPROVED TRUSS LAYOUT
03/12/2024 Approved Plans APPROVED TRUSS PACKAGE
03/14/2024 H4 # 121 - PERMIT APP
03/14/2024 Permit Codes Residential Plan Review
03/18/2024 Permit Codes Residential Plan Review
03/18/2024 Plot Plan approved plot plan
03/18/2024 Permit DS Building Permit
03/18/2024 Receipt Receipt for transaction:2024-001676
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter Stop Work Order
04/15/2024 3RD Party Insp Report THIRD PARTY INSPECTION
04/16/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 3RD Party Insp Report BASSWOOD - 3RD CAR GARAGE TOP PLATE - 240703 (1)
07/11/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/08/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Receipt Receipt for transaction:2024-007631
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/13/2024 Receipt Receipt for transaction:2024-007668
10/03/2024 HT #121 - TCO Extension App 10_3_2024
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/04/2024 Receipt Receipt for transaction:2024-008108
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter Codes 10 Day Letter
12/03/2024 HT #120 - TCO extension 12_3_24
12/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/03/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/03/2024 Receipt Receipt for transaction:2024-009288
01/03/2025 Application Form HT 121 TCOExtension Request Form
01/03/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/03/2025 Receipt Receipt for transaction:2025-000040
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001507
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter Field Certificate of Occupancy
03/13/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home