Summary
PRRES20240887
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK. See PRRES20220599 for Footing, sewer, water, under slab inspections. Andrea Sessler 02/27/2024 4:57 PM
02/27/2024
03/04/2024
11/15/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $777.59 $777.59 Paid 03/04/2024
$1,555.18
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 3/5/2024 3/5/2024 03/05/2024
Miscellaneous Correction
Corrective Action Required
03/05/2024
Exterior garage and back patio door portal passed and is okay to cover. Interior garage hold down straps are not installed at the time of portal inspection
Piers/Caissons Inspection - Residential Passed 3/8/2024 03/08/2024
Miscellaneous Correction
Informational
03/08/2024
Back deck piers passed by a third party
Gas Service Inspection - Residential Passed 3/13/2024 3/13/2024 03/13/2024
All Rough Inspection - Residential Failed 4/9/2024 4/9/2024 04/09/2024
Miscellaneous Correction
Resolved
04/09/2024
Exterior garage and back patio door portal passed and is okay to cover. Interior garage hold down straps are not installed at the time of portal inspection
Miscellaneous Correction
Corrective Action Required
04/09/2024
1840 SW Sage Canyon. All rough -Garage portal hold down straps are still not installed -Small garage overhead door sole plate is missing anchor bolts -Hip above 3rd car garage can not be supported by the ceiling joist -Garage ridge support in garage at laundry room needs to have a stud pack installed for proper load transfer -Purlin supporting roof above master closet and garage needs a stud pack install for proper load transfer -Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support -Fire block top plate in laundry room -Nails missing in LIB in master closet -Hip and purlin in master bedroom does not have a proper transfer of vertical load stud pack is needed -Double LVL in great room to master bedroom only has one king stud and one jack stud installed for vertical load transfer -Main ridge has a rafter that is more than 1 1/2 inches off set from the other side -Ridge above foyer has two purlins that do not have proper load transfer along the hallway bathroom -Ridge in foyer and purlin above bedroom two does not have the proper load transfer in wall between the two -Basement family room exterior wall is not vertically fire blocked every 10 feet on center
Electrical Service Inspection Passed 4/9/2024 04/09/2024
Erosion Control Inspection Residential Partial 4/9/2024 04/09/2024
Miscellaneous Correction
Informational
04/09/2024
Full erosion control is in place and needs to be maintained until CofO
All Rough Inspection - Residential Failed 4/15/2024 4/15/2024 04/15/2024
Miscellaneous Correction
Resolved
04/15/2024
1840 SW Sage Canyon. All rough -Garage portal hold down straps are still not installed -Small garage overhead door sole plate is missing anchor bolts -Hip above 3rd car garage can not be supported by the ceiling joist -Garage ridge support in garage at laundry room needs to have a stud pack installed for proper load transfer -Purlin supporting roof above master closet and garage needs a stud pack install for proper load transfer -Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support -Fire block top plate in laundry room -Nails missing in LIB in master closet -Hip and purlin in master bedroom does not have a proper transfer of vertical load stud pack is needed -Double LVL in great room to master bedroom only has one king stud and one jack stud installed for vertical load transfer -Main ridge has a rafter that is more than 1 1/2 inches off set from the other side -Ridge above foyer has two purlins that do not have proper load transfer along the hallway bathroom -Ridge in foyer and purlin above bedroom two does not have the proper load transfer in wall between the two -Basement family room exterior wall is not vertically fire blocked every 10 feet on center
Miscellaneous Correction
Corrective Action Required
04/15/2024
1840 SW Sage Canyon. All rough -Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support (engineers letter has not been uploaded as of the time of re inspection data input.1:35 PM) -Ridge above foyer has two purlins that do not have proper load transfer along the hallway bathroom -Basement family room exterior wall is not vertically fire blocked every 10 feet on center (foam below newly fire blocking wall is missing)
All Rough Inspection - Residential Failed 4/18/2024 4/18/2024 04/18/2024
Miscellaneous Correction
Resolved
04/18/2024
1840 SW Sage Canyon. All rough -Garage portal hold down straps are still not installed -Small garage overhead door sole plate is missing anchor bolts -Hip above 3rd car garage can not be supported by the ceiling joist -Garage ridge support in garage at laundry room needs to have a stud pack installed for proper load transfer -Purlin supporting roof above master closet and garage needs a stud pack install for proper load transfer -Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support -Fire block top plate in laundry room -Nails missing in LIB in master closet -Hip and purlin in master bedroom does not have a proper transfer of vertical load stud pack is needed -Double LVL in great room to master bedroom only has one king stud and one jack stud installed for vertical load transfer -Main ridge has a rafter that is more than 1 1/2 inches off set from the other side -Ridge above foyer has two purlins that do not have proper load transfer along the hallway bathroom -Ridge in foyer and purlin above bedroom two does not have the proper load transfer in wall between the two -Basement family room exterior wall is not vertically fire blocked every 10 feet on center
Miscellaneous Correction
Corrective Action Required
04/18/2024
1840 SW Sage Canyon. All rough (2) Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support (engineers letter has not been uploaded as of the time of re inspection 9:05 am)
All Rough Inspection - Residential Failed 4/26/2024 04/26/2024
Miscellaneous Correction
Resolved
04/26/2024
1840 SW Sage Canyon. All rough (2) Have engineer address where the cricket above the garage intersects and supports two roof loads without vertical support (engineers letter has not been uploaded as of the time of re inspection 9:05 am)
Miscellaneous Correction
Corrective Action Required
04/26/2024
Engineers letter uploaded into portal -New bracing for cricket roof support interferes with required attic access height. Attic access is required to have a minimum 30 inches of head clearance
All Rough Inspection - Residential Passed 5/6/2024 05/06/2024
Miscellaneous Correction
Resolved
05/06/2024
Engineers letter uploaded into portal -New bracing for cricket roof support interferes with required attic access height. Attic access is required to have a minimum 30 inches of head clearance
Erosion Control Inspection Residential Failed 6/10/2024 06/10/2024
Miscellaneous Correction
Resolved
06/10/2024
Full erosion control is in place and needs to be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence is torn down and needs to be repaired or replaced -Lot weeds and or grass is about 3 feet in height and needs to be trimmed
Sidewalk Inspection Failed 6/13/2024 06/13/2024
Misc
Informational
06/13/2024
6-13-24 PS Contractor not ready for sidewalk, TBD
Driveway Inspection Failed 6/13/2024 06/13/2024
Misc
Informational
06/13/2024
6-13-24 PS Driveway approach, contractor has forms in place but aggregate has not been compacted. Compact aggregate and recall for inspection prior to pour
Sidewalk Inspection Partial 6/14/2024 06/14/2024
Misc
Informational
06/13/2024
6-14-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approve to pour
Driveway Inspection Partial 6/14/2024 06/14/2024
Misc
Informational
06/13/2024
6-14-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Passed 6/20/2024 6/20/2024 06/19/2024
Misc
Informational
06/14/2024
6-14-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approve to pour 6-19-24 PS Sidewalk meets ADA and LS specs
Driveway Inspection Passed 6/20/2024 6/20/2024 06/19/2024
Misc
Informational
06/14/2024
6-14-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 6-19-24 PS Driveway approach meets ADA and LS specs
Erosion Control Inspection Residential Failed 7/24/2024 07/24/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/24/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence is torn down and needs to be repaired or replaced -Lot weeds and or grass is about 3 feet in height and needs to be trimmed
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/24/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence has been removed from the front of the property. Full erosion control measures are required and must be maintained until CofO
Erosion Control Inspection Residential Passed 8/27/2024 08/27/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/27/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence has been removed from the front of the property. Full erosion control measures are required and must be maintained until CofO
Plot Plan Inspection Passed 11/12/2024 11/12/2024
Occupancy Inspection - Codes Residential Failed 11/12/2024 11/12/2024 11/12/2024
Miscellaneous Correction
Corrective Action Required
11/12/2024
Exterior GFCI’s need to be for wet locations Front room windows are less than 24 inches up from the floor and need to be tempered glass Kitchen backsplash receptacle light/electric needs a spark ring installed Garage to house self closing door does not fully shut and lock Fire block gaps above overhead garage doors in the garage Sump pump has a open neutral Sump pump receptacle needs to state it is non GFCI protected Electrical panel in basement does not have a receptacle in the same room within 25 feet of the panel Sump pump does not have an extension attached Tightened 1/2 inch through bolt on back deck porch to beam connection A/C unit does not have anti siphon knobs installed Water heaters were not fully installed at the time of inspection
Occupancy Inspection - Codes Residential Full C of O 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Resolved
11/15/2024
Exterior GFCI’s need to be for wet locations Front room windows are less than 24 inches up from the floor and need to be tempered glass Kitchen backsplash receptacle light/electric needs a spark ring installed Garage to house self closing door does not fully shut and lock Fire block gaps above overhead garage doors in the garage Sump pump has a open neutral Sump pump receptacle needs to state it is non GFCI protected Electrical panel in basement does not have a receptacle in the same room within 25 feet of the panel Sump pump does not have an extension attached Tightened 1/2 inch through bolt on back deck porch to beam connection A/C unit does not have anti siphon knobs installed Water heaters were not fully installed at the time of inspection
Documents & Images
Date Uploaded File Type Document Name
02/27/2024 Application Form APPLICATION
02/27/2024 Approved Plans APPROVED PLANS
02/27/2024 Plot Plan APPROVED PLOT PLAN
02/28/2024 Permit Codes Residential Plan Review
03/04/2024 Permit DS Building Permit
03/04/2024 Receipt Receipt for transaction:2024-001297
03/05/2024 Letter INSPECTION SUMMARY
03/08/2024 3RD Party Insp Report 3rd Party pier inspection
03/08/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/24/2024 1840 SW Sage Canyon - Revised Roof Bracing Approval
04/26/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter Codes Final Certificate of Occupancy
11/15/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home