Permit Application Status

PRRES20240530


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240530
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
02/08/2024
02/14/2024
02/18/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/14/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 02/14/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 02/14/2024
9110078-Valuation Fee New Single Family $2,021.32 $2,021.32 Paid 02/14/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/20/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/04/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/25/2024 03/25/2024
Informational
03/25/2024
FOOTING APPROVED BY ENGINEER
Water Service Inspection - R Passed 3/25/2024 03/25/2024
Erosion Control Inspection Residential Failed 4/5/2024 04/05/2024
DCM5 ESC INSP DENIED
Corrective Action Required
04/05/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE MIN 3/4" GRAVEL AT LOT ENTRANCE AND EROSION CONTROL ALONG THE BACK SIDE OF LOT
Underslab Plumbing Inspection - Residential Failed 4/5/2024 4/5/2024 04/05/2024
Misc
Corrective Action Required
04/05/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE MIN 3/4" GRAVEL AT LOT ENTRANCE AND EROSION CONTROL ALONG THE BACK SIDE OF LOT
Erosion Control Inspection Residential Passed 4/10/2024 04/10/2024
DCM5 ESC INSP DENIED
Resolved
04/10/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE MIN 3/4" GRAVEL AT LOT ENTRANCE AND EROSION CONTROL ALONG THE BACK SIDE OF LOT
Underslab Plumbing Inspection - Residential Passed 4/10/2024 4/10/2024 04/10/2024
Misc
Resolved
04/10/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE MIN 3/4" GRAVEL AT LOT ENTRANCE AND EROSION CONTROL ALONG THE BACK SIDE OF LOT
Sewer Service Inspection - R Partial 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
House sewer connection to grinder pit-OK
All Rough Inspection - Residential Failed 8/7/2024 8/7/2024 08/07/2024
Misc
Corrective Action Required
08/07/2024
-Tie down bolts in garage not in center 1/3 of base plate -Missing Simpson joist hanger U210-3 between kitchen and great room -Half wall at covered deck not installed southeast corner, verify whether or not this is still part of the plan -Unable to locate supply lines to jacuzzi tub in master suite bathroom -Seal all exterior wall penetrations
All Rough Inspection - Residential Failed 8/15/2024 8/15/2024 08/15/2024
Misc
Corrective Action Required
08/07/2024
Water supply lines to jacuzzi tub in master suite bathroom not installed. **You need to move the pump receptacle to within direct view and within 12” of the access opening. Access for service must be unobstructed opening **OK TO INSULATE
All Rough Inspection - Residential Failed 8/22/2024 8/22/2024 08/22/2024
Misc
Corrective Action Required
08/15/2024
Water supply lines to jacuzzi tub in master suite bathroom not installed. **You need to move the pump receptacle to within direct view and within 12” of the access opening. Access for service must be unobstructed opening **OK TO INSULATE
Electrical Service Inspection Passed 9/18/2024 09/18/2024
Gas Service Inspection - Residential Passed 9/18/2024 09/18/2024
All Rough Inspection - Residential Passed 9/19/2024 9/19/2024 09/19/2024
Misc
Resolved
09/19/2024
Water supply lines to jacuzzi tub in master suite bathroom not installed. **You need to move the pump receptacle to within direct view and within 12” of the access opening. Access for service must be unobstructed opening **OK TO INSULATE
Driveway Inspection Partial 9/27/2024 9/27/2024 09/27/2024
Misc
Informational
09/27/2024
9-27-24 NS Site visited and it appears driveway meets city standards for pre-pour
Driveway Inspection Passed 10/8/2024 10/8/2024 10/07/2024
Misc
Informational
09/27/2024
9-27-24 NS Site visited and it appears driveway meets city standards for pre-pour 10-7-24 NS site visited and it appears driveways has passed
Occupancy Inspection - Codes Residential Failed 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/17/2024
**Provide erosion control around the rear lot corner storm inlet -Sewer was not fully inspected and approved -Provide sewer tracer wire port at grade -Provide an airtight plug at sewer clean out -Lag deck ledger board to floor rim board per code -Support short deck beam to house with approved hanger -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections. Provide verification -Reinstall cover at front receptacle -Install floor receptacle box spark ring flushed with wood floor -Secure FMC within 12” of cooktop connection -Fb penetration of garage wall below sink -Provide min 12”x12” clear access opening to hydro tub motor, secure electrical wiring within 8” of receptacle box -Pendant light cannot be located within a tub zone -Move clothes washer out from wall for inspection -Stair riser height shall be no more than 7-3/4” with maximum riser height difference of no more than 3/8” -Install backflow preventer at hose bibb -Install receptacle face plate inside basement bathroom
Sewer Service Inspection - R Passed 12/20/2024 12/20/2024
Misc
Resolved
12/20/2024
House sewer connection to grinder pit-OK
Occupancy Inspection - Codes Residential Ready for Temp CO 12/20/2024 12/20/2024 12/20/2024
Misc
Corrective Action Required
12/17/2024
-Provide sewer tracer wire port at grade -Lag deck ledger board to floor rim board per code -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections. Provide verification of the framing per Vista Engineering letter
Occupancy Inspection - Codes Residential Ready for Temp CO 2/3/2025 02/03/2025
Misc
Corrective Action Required
12/20/2024
-Provide sewer tracer wire port at grade -Lag deck ledger board to floor rim board per code -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections. Provide verification of the framing per Vista Engineering letter
Occupancy Inspection - Codes Residential Failed 2/6/2025 2/6/2025 02/06/2025
Misc
Corrective Action Required
02/03/2025
-Provide sewer tracer wire port at grade -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections. Provide verification of the framing per Vista Engineering letter **Not done per engineer letter
Occupancy Inspection - Codes Residential Full C of O 2/18/2025 2/18/2025 02/18/2025
Misc
Resolved
02/18/2025
-Provide sewer tracer wire port at grade -Attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections. Provide verification of the framing per Vista Engineering letter **Not done per engineer letter
Documents & Images
Date Uploaded File Type Document Name
02/08/2024 WLO010 WEGNER - Sealed Plans (Feb 6, 2024) (FINAL PLANS)
02/09/2024 Application Page 1
02/09/2024 Application page 2
02/09/2024 Excise Tax page 1
02/09/2024 Excise tax page 2
02/09/2024 Excise tax page 3
02/09/2024 Excise tax page 4
02/13/2024 Plot Plan approved plot plan
02/13/2024 Permit Codes Residential Plan Review
02/13/2024 Application Form APPROVED PLANS
02/13/2024 Permit Codes Residential Plan Review
02/14/2024 Receipt Receipt for transaction:2024-000843
02/29/2024 Engineer Report/Study ENG LETTER
02/29/2024 Engineer Report/Study pier plan detail
03/13/2024 3RD Party Insp Report Footing Inspection Report 3-13-24
03/25/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter DS Building Permit
03/29/2024 3RD Party Insp Report _HPier_LSMO_Walker Custom Homes
04/05/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
08/07/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/19/2024 Inspection Letter 2528 NE Woodland Oak Circle_ Lees Summit_ MO 64086 - Lot 10
12/19/2024 2528 NE Woodland Oak Circle - Structural Letter (December 19, 2024)
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/20/2024 Receipt Receipt for transaction:2024-009633
01/09/2025 Schedule for Completion
01/09/2025 Substantial Completion & TCO Extension Request
02/04/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/04/2025 Receipt Receipt for transaction:2025-000697
02/06/2025 Letter INSPECTION SUMMARY
02/17/2025 Engineer Report/Study Structural Inspection
02/18/2025 Letter Codes Final Certificate of Occupancy
02/18/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home