PRRES20240374


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240374
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
01/30/2024
02/06/2024
07/30/2024
03/11/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 02/06/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/06/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 02/06/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 02/06/2024
Water Meter Fee $680.46 $680.46 Paid 02/06/2024
Valuation Fee New Single Family $1,960.07 $1,960.07 Paid 02/06/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/14/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/26/2024 2/26/2024 02/26/2024
Erosion Control Inspection Residential Failed 2/26/2024 02/26/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Sewer Service Inspection - R Passed 3/1/2024 03/01/2024
Water Service Inspection - R Passed 3/5/2024 03/05/2024
Underslab Plumbing Inspection - Residential Passed 3/20/2024 3/20/2024 03/20/2024
Erosion Control Inspection Residential Failed 3/20/2024 3/20/2024 03/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair downed silt fence at front of lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Partial 6/26/2024 6/26/2024 06/26/2024
Misc
Informational
06/26/2024
Garage portal frame nailing inspected.
Electrical Service Inspection Passed 9/3/2024 9/3/2024 09/03/2024
All Rough Inspection - Residential Failed 9/3/2024 9/3/2024 09/03/2024
Misc
Resolved
09/03/2024
Garage portal frame nailing inspected.
Misc
Corrective Action Required
09/03/2024
-fire block garage rear wall into fire down -furr around hvac in garage and fire block -install tension straps at phf per table and code -missing truss hangers throughout -anchor bolts to be within 12” of plate breaks (not closer than 7x the diameter of the bolt) -complete furr down in great room and fire block -wsp at interior stairwell wall per plans and code -missing all lib bracing throughout -uncover front patio to inspect trusses and nailing -block sheathing breaks throughout -missing hold downs bed 2 -install all roof boots -missing stud at hvac chance in primary bed
Erosion Control Inspection Residential Partial 9/5/2024 09/05/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/05/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair downed silt fence at front of lot
DCM3 ESC REQUIRED 2 DAY
Resolved
09/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
09/05/2024
In complicated at time of inspection
All Rough Inspection - Residential Failed 9/5/2024 9/5/2024 09/05/2024
Misc
Corrective Action Required
09/03/2024
-fire block garage rear wall into fire down-SEAL GAPS -furr around hvac in garage and fire block-PAN OFF TOP OF CHASE -complete furr down in great room and fire block-FIREBLOCK TOP OF CHASE LEFT SIDE -wsp at interior stairwell wall per plans and code-COMPLETE NAILING PATTERN AT PANEL EDGES -missing all lib bracing throughout-COMPLETE BRACED WALL LENGTHS PER PLAN -missing stud at hvac chance in primary bed
All Rough Inspection - Residential Failed 9/12/2024 9/12/2024 09/12/2024
Misc
Corrective Action Required
09/05/2024
-furr around hvac in garage and fire block-PAN OFF TOP OF CHASE -complete furr down in great room and fire block-FIREBLOCK TOP OF CHASE LEFT SIDE
All Rough Inspection - Residential Passed 9/18/2024 9/18/2024 09/18/2024
Misc
Resolved
09/18/2024
-furr around hvac in garage and fire block-PAN OFF TOP OF CHASE -complete furr down in great room and fire block-FIREBLOCK TOP OF CHASE LEFT SIDE
Gas Service Inspection - Residential Passed 10/16/2024 10/16/2024 10/16/2024
Driveway Inspection Partial 10/23/2024 10/23/2024 10/23/2024
Misc
Informational
10/23/2024
10-23-24 Dustin A , Dw is formed and compacted. Approved to pour
Driveway Inspection Passed 10/31/2024 10/31/2024 10/30/2024
Misc
Informational
10/23/2024
10-23-24 Dustin A , Dw is formed and compacted. Approved to pour 10-30-24 Dustin A, DW was poured to city specs. Passed
Occupancy Inspection - Codes Residential Failed 11/12/2024 11/12/2024 11/12/2024
Miscellaneous Correction
Corrective Action Required
11/12/2024
Step up riser to the front porch is over the IRC allowance of 7 3/4 inches in height Step up riser from basement to transaction platform with carpet is over the code allowance of 7 3/4 inches Basement to intermediate stairwell platform needs to have a light switch installed Garage Fire block gaps in garage above overhead garage doors Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 11/13/2024 11/13/2024 11/13/2024
Miscellaneous Correction
Resolved
11/13/2024
Step up riser to the front porch is over the IRC allowance of 7 3/4 inches in height Step up riser from basement to transaction platform with carpet is over the code allowance of 7 3/4 inches Basement to intermediate stairwell platform needs to have a light switch installed Garage Fire block gaps in garage above overhead garage doors Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations
Miscellaneous Correction
Corrective Action Required
11/13/2024
3225 SW Arbor Tree Dr. occupancy Step up riser to the front porch is over the IRC allowance of 7 3/4 inches in height Step up riser from basement to transaction platform with carpet is over the code allowance of 7 3/4 inches Fire block gaps in garage above overhead garage doors Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations
Occupancy Inspection - Codes Residential Ready for Temp CO 11/14/2024 11/14/2024 11/14/2024
Miscellaneous Correction
Resolved
11/14/2024
3225 SW Arbor Tree Dr. occupancy Step up riser to the front porch is over the IRC allowance of 7 3/4 inches in height Step up riser from basement to transaction platform with carpet is over the code allowance of 7 3/4 inches Fire block gaps in garage above overhead garage doors Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations
Miscellaneous Correction
Corrective Action Required
11/14/2024
Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations Final grading was not completed for plot plan inspection Passed for TCO only
Occupancy Inspection - Codes Residential Full C of O 3/11/2025 3/11/2025 03/11/2025
Miscellaneous Correction
Resolved
03/11/2025
Sod, splash pads and sump pump extension are not installed Seal all exterior penetrations Final grading was not completed for plot plan inspection Passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
01/30/2024 Application Form H4 # 115 - PERMIT APP
02/01/2024 Permit Codes Residential Plan Review
02/01/2024 Approved Plans APPROVED PLANS
02/01/2024 Approved Plans APPROVED TRUSS LAYOUT
02/01/2024 Approved Plans APPROVED TRUSS PACKAGE
02/05/2024 Plot Plan approved plot plan
02/06/2024 Permit DS Building Permit
02/06/2024 Receipt Receipt for transaction:2024-000641
02/24/2024 M L Crose 3225 SW Arbor Tree Dr LSMO Clayton Properties Permit 2024-0374 3rd Party Footing Inspection Report 2-23-24
02/26/2024 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/05/2024 Letter INSPECTION SUMMARY
09/05/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/14/2024 Receipt Receipt for transaction:2024-008957
01/03/2025 Application Form HT 115 TCOExtension Request Form
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction:2025-001432
03/11/2025 Letter Field Certificate of Occupancy
03/11/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home