Permit Application Status

PRRES20236649


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236649
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASMENT - COVERED DECK
12/21/2023
12/28/2023
08/27/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 12/28/2023
Right of Way Permit Fee $85.00 $85.00 Paid 12/28/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/28/2023
Water Tap Fee $3,760.00 $3,760.00 Paid 12/28/2023
Water Meter Fee $680.46 $680.46 Paid 12/28/2023
Valuation Fee New Single Family $2,600.39 $2,600.39 Paid 12/28/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/7/2024 2/7/2024 02/07/2024
Erosion Control Inspection Residential Failed 02/07/2024
Misc
Corrective Action Required
02/07/2024
**Clean mud and debris from streets -Perimeter methods in compliance at time of inspection but mud has been tracked all along the street from the adjoining lot from pier and foundation work
Plot Plan Inspection Passed 02/07/2024
Piers/Caissons Inspection - Residential Passed 02/07/2024
Underslab Plumbing Inspection - Residential Failed 2/27/2024 2/27/2024 02/27/2024
Misc
Corrective Action Required
02/27/2024
Repair or replace damaged interior drain tile at SE corner
Erosion Control Inspection Residential Partial 02/27/2024
Misc
Informational
02/27/2024
Erosion control in compliance at time of inspection
Underslab Plumbing Inspection - Residential Passed 2/27/2024 2/27/2024 02/27/2024
Misc
Resolved
02/27/2024
Repair or replace damaged interior drain tile at SE corner
Sewer Service Inspection - R Passed 3/6/2024 3/6/2024 03/06/2024
Erosion Control Inspection Residential Failed 3/6/2024 03/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/06/2024
EROSION CONTROL REQUIRED ALONG THE STREET AND ALONG THE REAR FLOOD BASIN. **NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Passed 3/12/2024 3/12/2024 03/12/2024
Electrical Service Inspection Failed 5/15/2024 5/15/2024 05/15/2024
Misc
Corrective Action Required
05/15/2024
-Land conductors from main service panel to sub panel -Bond gas line
Gas Service Inspection - Residential Failed 5/15/2024 5/15/2024 05/15/2024
Misc
Corrective Action Required
05/15/2024
-No pressure at gauge
All Rough Inspection - Residential Failed 5/15/2024 5/15/2024 05/15/2024
Misc
Corrective Action Required
05/15/2024
-Can light above toilet in owners suite light too close to DWV -Per M1308.2.1 boca plates required top and bottom at all mechanicals throughout -Collar ties required every 4 ft in garage -Nail all exterior corners to code -Missing fire blocking great room ceiling under tub -Plans call for three continuous 2x4 at stairs next to LIB in great room -Bearing at stair stringers needs to be an 1 1/2” at platform and on 2x10 -Front entry waste line over notched at floor joist -Closet of bedroom 4 fire blocking at HVAC chase -SE corner missing tie down nuts/washers -Tie down bolts in basement not in middle 1/3rd
All Rough Inspection - Residential Failed 5/20/2024 5/20/2024 05/20/2024
Misc
Partial Correction
05/20/2024
-Front entry waste line over notched at floor joist
Electrical Service Inspection Passed 5/20/2024 5/20/2024 05/20/2024
Misc
Resolved
05/20/2024
Gas Service Inspection - Residential Passed 5/20/2024 5/20/2024 05/20/2024
Misc
Resolved
05/20/2024
All Rough Inspection - Residential Passed 5/24/2024 5/24/2024 05/24/2024
Misc
Resolved
05/24/2024
Sidewalk Inspection Partial 5/30/2024 5/30/2024 05/30/2024
Misc
Informational
05/30/2024
5-30-24 Dustin A, SW hasc been formed and compacted to city specs. Approved to pour
Driveway Inspection Partial 5/30/2024 5/30/2024 05/30/2024
Misc
Informational
05/30/2024
5-30-24 Dustin A, DW has been formed and compacted to city specs. Approved to pour
Driveway Inspection Passed 6/6/2024 6/6/2024 06/06/2024
Misc
Informational
05/30/2024
5-30-24 Dustin A, DW has been formed and compacted to city specs. Approved to pour 6-6-24 Dustin A, Dw Was poured to city specs and slopes are in compliance. Passed
Sidewalk Inspection Passed 6/6/2024 6/6/2024 06/06/2024
Misc
Informational
05/30/2024
5-30-24 Dustin A, SW hasc been formed and compacted to city specs. Approved to pour 6-6-24 Dustin A, SW has been poured to city specs and slopes are in compliance. Passed
Erosion Control Inspection Residential Passed 8/27/2024 08/27/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/27/2024
EROSION CONTROL REQUIRED ALONG THE STREET AND ALONG THE REAR FLOOD BASIN. **NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 8/27/2024 8/27/2024 08/27/2024
Documents & Images
Date Uploaded File Type Document Name
12/21/2023 2023_12_20_Lot 193 Woodside Ridge_Apex_Permit Sealed
12/21/2023 LOT 193 FINAL
12/21/2023 WR193 - Lee's Summit Permit Application Packet
12/28/2023 Approved Plans approved plans
12/28/2023 Plot Plan approved plot plan
12/28/2023 Permit Codes Residential Plan Review
12/28/2023 Permit DS Building Permit
12/28/2023 Receipt Receipt for transaction:2023-009335
02/06/2024 2233 NW Killarney Ln_PIER INSP_2024-02-05
02/06/2024 2233 NW KILLARNEY LN_PIER PLAN_1-31-24
02/07/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
02/27/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter Eng. report
05/24/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter Field Certificate of Occupancy
08/27/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home