Permit Application Status

PRRES20234959


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20234959
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT-WALKUP BASEMENT. FINISHED/UNFNISHED BASEMENT. COVERED DECK.
09/28/2023
10/11/2023
04/06/2024
03/19/2024
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
Bill Seachrest, Address:350 SW Longview Blvd, Phone:(816) 786-8876  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
S&B Plumbing, Inc., Address:PO Box 101, Phone:(913) 850-3445  
SARA@ELEVATEDESIGNBUILDKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 10/11/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 10/11/2023
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 10/11/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/11/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 10/11/2023
9110078-Valuation Fee New Single Family $1,549.24 $1,549.24 Paid 10/11/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/18/2023 10/18/2023
Miscellaneous Correction
Informational
10/18/2023
(6) 36x36 inch pads were installed under the foundation at the time of footing inspection
Foundation Inspection - Residential Passed 10/23/2023 (3:00) 10/23/2023 10/23/2023
Underslab Plumbing Inspection - Residential Passed 11/7/2023 11/7/2023 11/07/2023
Sewer Service Inspection - R Passed 11/7/2023 11/07/2023
Water Service Inspection - R Passed 11/10/2023 (11:30) 11/10/2023 11/10/2023
All Rough Inspection - Residential Partial 12/1/2023 12/01/2023
Misc
Informational
12/01/2023
Garage portal okay to cover. Rear cspf sheathing breaks to occur in the middle 24”
All Rough Inspection - Residential Partial 12/4/2023 12/4/2023 12/04/2023
Misc
Informational
12/01/2023
Garage portal and rear cspf okay to cover.
Electrical Service Inspection Passed 12/28/2023 12/28/2023
Gas Service Inspection - Residential Passed 12/28/2023 12/28/2023
Erosion Control Inspection Residential Failed 12/28/2023 12/28/2023
Miscellaneous Correction
Corrective Action Required
12/28/2023
West side of property needs a barrier installed between the two homes
All Rough Inspection - Residential Failed 12/28/2023 12/28/2023 12/28/2023
Misc
Informational
12/04/2023
Garage portal and rear cspf okay to cover.
Miscellaneous Correction
Corrective Action Required
12/28/2023
2207 SW Hook Farm all rough -Garage is missing one electrical wall outlet -Two corners in garage need to be nailed off at the corners -Entry needs one electrical outlet installed -Roof to wall purlin in living room needs studs installed to transfer load -Fire block living room top plate east wall -Three joist hangers in the kitchen at LVL are missing nails -Ridge rafters above east living room wall needs to be off set no more than 1 1/2 inches -Primary bedroom has a corner stud cut and needs to be replaced -Primary bathroom needs a double stud shoe on outside wall -air supply lines in the basement ceiling needs to be supported 10 feet on centers -Air supply return in basement living room needs to be sealed -Joist hanger in basement living room is missing and other hangers are missing nails -Basement shop room is missing joist hangers and nails under the primary bedroom -Anchor bolt in basement shop needs to be in the middle 1/3 sole plate -Nail basement corners 12 inches on center -Floor joist for bathroom between bed 2 and 3 has been over notched in the top of the floor joist
All Rough Inspection - Residential Failed 1/3/2024 1/3/2024 01/03/2024
Misc
Informational
12/28/2023
Garage portal and rear cspf okay to cover.
Miscellaneous Correction
Partial Correction
01/03/2024
2207 SW Hook Farm all rough -Garage is missing one electrical wall outlet -Two corners in garage need to be nailed off at the corners -Entry needs one electrical outlet installed -Roof to wall purlin in living room needs studs installed to transfer load -Fire block living room top plate east wall -Three joist hangers in the kitchen at LVL are missing nails -Ridge rafters above east living room wall needs to be off set no more than 1 1/2 inches -Primary bedroom has a corner stud cut and needs to be replaced -Primary bathroom needs a double stud shoe on outside wall -air supply lines in the basement ceiling needs to be supported 10 feet on centers -Air supply return in basement living room needs to be sealed -Joist hanger in basement living room is missing and other hangers are missing nails -Basement shop room is missing joist hangers and nails under the primary bedroom -Anchor bolt in basement shop needs to be in the middle 1/3 sole plate -Nail basement corners 12 inches on center -Floor joist for bathroom between bed 2 and 3 has been over notched in the top of the floor joist
Miscellaneous Correction
Corrective Action Required
01/03/2024
2207 SW Hook Farm all rough (2) -Primary bathroom needs a double stud shoe installed on outside wall where vent pipe is ran through the two studs -Joist hanger in basement living room up against the stairwell needs to have a joist hanger installed that support the full 2x10 joist, a one sided hanger was installed -Floor joist in the basement for bathroom between bed 2 and 3 has been over notched in the top of the floor joist. (IRC R502.1.11) furnish engineers report since the first joist and now the added second joist are both notched in the upper 2 inches of the joist
All Rough Inspection - Residential Failed 1/4/2024 1/4/2024 01/04/2024
Misc
Informational
01/03/2024
Garage portal and rear cspf okay to cover.
Miscellaneous Correction
Resolved
01/04/2024
2207 SW Hook Farm all rough -Garage is missing one electrical wall outlet -Two corners in garage need to be nailed off at the corners -Entry needs one electrical outlet installed -Roof to wall purlin in living room needs studs installed to transfer load -Fire block living room top plate east wall -Three joist hangers in the kitchen at LVL are missing nails -Ridge rafters above east living room wall needs to be off set no more than 1 1/2 inches -Primary bedroom has a corner stud cut and needs to be replaced -Primary bathroom needs a double stud shoe on outside wall -air supply lines in the basement ceiling needs to be supported 10 feet on centers -Air supply return in basement living room needs to be sealed -Joist hanger in basement living room is missing and other hangers are missing nails -Basement shop room is missing joist hangers and nails under the primary bedroom -Anchor bolt in basement shop needs to be in the middle 1/3 sole plate -Nail basement corners 12 inches on center -Floor joist for bathroom between bed 2 and 3 has been over notched in the top of the floor joist
Miscellaneous Correction
Resolved
01/04/2024
2207 SW Hook Farm all rough (2) -Primary bathroom needs a double stud shoe installed on outside wall where vent pipe is ran through the two studs -Joist hanger in basement living room up against the stairwell needs to have a joist hanger installed that support the full 2x10 joist, a one sided hanger was installed -Floor joist in the basement for bathroom between bed 2 and 3 has been over notched in the top of the floor joist. (IRC R502.1.11) furnish engineers report since the first joist and now the added second joist are both notched in the upper 2 inches of the joist
Miscellaneous Correction
Corrective Action Required
01/04/2024
A revised engineers letter is needed for the over notched and recommended repair of the bathroom floor joist which needs to include the property address and permit number. Okay to insulate
All Rough Inspection - Residential Passed 1/16/2024 01/16/2024
Misc
Informational
01/04/2024
Garage portal and rear cspf okay to cover.
Miscellaneous Correction
Resolved
01/16/2024
A revised engineers letter is needed for the over notched and recommended repair of the bathroom floor joist which needs to include the property address and permit number. Okay to insulate
Driveway Inspection Partial 1/31/2024 1/31/2024 01/31/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, Dw is compacted and depths are in compliance , Approved to pour.
Driveway Inspection Passed 2/7/2024 2/7/2024 02/06/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, Dw is compacted and depths are in compliance , Approved to pour. 2-6-24 Dustin A, DW is poured. Slopes are in compliance. Passed
Sidewalk Inspection Failed 2/6/2024 02/06/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need to apply white cure 2-6-24 Dustin A, Sidewalk is poured and slopes are in compliance. There is one panel that is chipped\broken that will need to be replaced. Will need to call in a pre pour when replacing panel
Sidewalk Inspection Failed 2/7/2024 2/7/2024 02/06/2024
Misc
Informational
01/31/2024
1-31-24 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need to apply white cure. 2-6-24 Dustin A, Panel is chipped \ broken. Will need to be replaced.
Sidewalk Inspection Passed 3/5/2024 3/5/2024 03/05/2024
Misc
Informational
02/06/2024
1-31-24 Dustin A, Sw is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need to apply white cure. 2-6-24 Dustin A, Panel is chipped \ broken. Will need to be replaced. 3-5-24 Dustin A, Passed
Occupancy Inspection - Codes Residential Failed 3/12/2024 3/12/2024 03/12/2024
Misc
Corrective Action Required
03/12/2024
-provide as graded plot plan -all outlets in laundry to be GFCI protected -spark rings on kitchen backsplash outlets where -lable all non GFCI outlets in unfinished spaces -repair drywall at garage entry into living space -garage door to be self closing and latching -water anti syphon device on basement spigot with set screw sheered off at -secure conduit at water heater in basement -secure A/c disconnect whip within 12”
Plot Plan Inspection Passed 03/19/2024
Erosion Control Inspection Residential Passed 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
West side of property needs a barrier installed between the two homes
Occupancy Inspection - Codes Residential Full C of O 3/19/2024 3/19/2024 03/19/2024
Misc
Resolved
03/19/2024
-lable all non GFCI outlets in unfinished spaces -repair drywall at garage entry into living space -garage door to be self closing and latching -water anti syphon device on basement spigot with set screw sheered off at -secure conduit at water heater in basement -secure A/c disconnect whip within 12”
Documents & Images
Date Uploaded File Type Document Name
09/28/2023 License_Tax_Application
09/28/2023 LS_tax_signed
10/03/2023 Permit Codes Residential Plan Review
10/09/2023 Plot Plan APPROVED PLOT PLAN
10/09/2023 Permit Codes Residential Plan Review
10/10/2023 Residental Permit Application_REV2
10/10/2023 Approved Plans APPROVED PLANS
10/10/2023 Permit Codes Residential Plan Review
10/11/2023 Permit DS Building Permit
10/11/2023 Receipt Receipt for transaction:2023-007685
10/18/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
12/01/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
01/02/2024 Elevate Joist Notch Calculation
01/03/2024 Letter INSPECTION SUMMARY
01/04/2024 Trust Document (Randy Ramos)
01/04/2024 Joist Repair for 2207 S_W_ Brook Farm Dr_
01/04/2024 Letter INSPECTION SUMMARY
01/16/2024 Letter INSPECTION SUMMARY
01/31/2024 Letter INSPECTION SUMMARY
01/31/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/13/2024 Plot Plan approved as graded plot plan
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter Field Certificate of Occupancy
03/19/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home