Permit Application Status

PRRES20234839


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20234839
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PORCH. STOP WORK ORDER generated on 10/23/2023 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 10/26/2023 12:00 AM by username 'Shawn Hoffman'.
09/22/2023
10/18/2023
04/13/2024
07/19/2024
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
PAUL@BELLAHHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 10/18/2023
Water Meter Fee $680.46 $680.46 Paid 10/18/2023
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 10/18/2023
Right of Way Permit Fee $85.00 $85.00 Paid 10/18/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/18/2023
Valuation Fee New Single Family $1,599.51 $1,599.51 Paid 10/18/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 07/11/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/23/2023 10/23/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/23/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Passed 10/23/2023 10/23/2023
Misc
Informational
10/23/2023
Inspection by third party.
Erosion Control Inspection Residential Failed - Stop Work 10/23/2023 10/23/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/23/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Partial 10/26/2023 10/26/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/26/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Informational
10/26/2023
- Erosion ok at time of inspection.
Erosion Control Inspection Residential Failed 10/27/2023 10/27/2023
DCM3 ESC REQUIRED 2 DAY
Informational
10/26/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - Remove mud and debris from street and sidewalk.
Underslab Plumbing Inspection - Residential Passed 11/23/2023 11/27/2023 11/27/2023
Sewer Service Inspection - R Passed 11/30/2023 11/30/2023
Water Service Inspection - R Partial 11/30/2023 11/30/2023
Misc
Corrective Action Required
11/30/2023
Partial- pex out of foundation 18 ft.
Water Service Inspection - R Passed 12/1/2023 12/1/2023 12/01/2023
Misc
Resolved
12/01/2023
Partial- pex out of foundation 18 ft.
Erosion Control Inspection Residential Failed 2/26/2024 02/26/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
02/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - Remove mud and debris from street and sidewalk.
Misc
Corrective Action Required
02/26/2024
- REMOVE TRASH AND DEBRIS FROM LOT - REMOVE GRAVEL FROM STREET
All Rough Inspection - Residential Failed 3/8/2024 3/8/2024 03/08/2024
Misc
Corrective Action Required
03/08/2024
-No access. Property locked no lockbox code provided. No answer when called.
Electrical Service Inspection Failed 3/8/2024 3/8/2024 03/08/2024
Misc
Corrective Action Required
03/08/2024
-No access.
Gas Service Inspection - Residential Failed 3/8/2024 3/8/2024 03/08/2024
Misc
Corrective Action Required
03/08/2024
-No access.
All Rough Inspection - Residential Not Ready 3/11/2024 3/11/2024 03/11/2024
Misc
Corrective Action Required
03/08/2024
- INSPECTION DENIED - NO PLANS IN SIGHT, AND NO ANSWER BY CONTRACTOR - PROVIDE CITY STAMPED PLANS
Electrical Service Inspection Failed 3/11/2024 3/11/2024 03/11/2024
Misc
Corrective Action Required
03/08/2024
- NO PLANS IN SIGHT, AND NO ANSWER BY CONTRACTOR - PROVIDE CITY STAMPED PLANS
Gas Service Inspection - Residential Failed 3/11/2024 3/11/2024 03/11/2024
Misc
Corrective Action Required
03/08/2024
- NO PLANS IN SIGHT, AND NO ANSWER BY CONTRACTOR - PROVIDE CITY STAMPED PLANS
All Rough Inspection - Residential Failed 3/12/2024 3/12/2024 03/12/2024
Misc
Resolved
03/12/2024
- INSPECTION DENIED - NO PLANS IN SIGHT, AND NO ANSWER BY CONTRACTOR - PROVIDE CITY STAMPED PLANS
Misc
Corrective Action Required
03/12/2024
- Grid pattern nailing of portal frame missing on one side - Anchor bolts of portal frame to be middle third of plate and missing 2” washers and nuts - Plans call for 7 studs under I-beam in garage - Solid block sheeting breaks throughout garage - Provide joist hangers basement bottom of stairs , un supported or not enough support - Secure SEC cable within 12” of entry into garage
Gas Service Inspection - Residential Failed 3/12/2024 3/12/2024 03/12/2024
Misc
Corrective Action Required
03/11/2024
- complete bonding
Electrical Service Inspection Failed 3/12/2024 03/12/2024
Misc
Corrective Action Required
03/11/2024
- bond gas line
Gas Service Inspection - Residential Passed 3/14/2024 3/14/2024 03/14/2024
Misc
Resolved
03/14/2024
- complete bonding
Electrical Service Inspection Passed 3/14/2024 3/14/2024 03/14/2024
Misc
Resolved
03/14/2024
- bond gas line
All Rough Inspection - Residential Failed 3/14/2024 3/14/2024 03/14/2024
Misc
Corrective Action Required
03/12/2024
- Grid pattern nailing of portal frame missing on one side - Anchor bolts of portal frame to be middle third of plate and missing 2” washers and nuts - Plans call for 7 studs under I-beam in garage - Solid block sheeting breaks throughout garage - Provide joist hangers basement bottom of stairs , un supported or not enough support
All Rough Inspection - Residential Passed 3/15/2024 03/15/2024
Misc
Resolved
03/15/2024
- Grid pattern nailing of portal frame missing on one side - Anchor bolts of portal frame to be middle third of plate and missing 2” washers and nuts - Plans call for 7 studs under I-beam in garage - Solid block sheeting breaks throughout garage - Provide joist hangers basement bottom of stairs , un supported or not enough support
Erosion Control Inspection Residential Passed 5/2/2024 5/2/2024 05/02/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/29/2024
4-29-24 DP. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Also, Clean up the intersection of Redbuck CIr & SW Mary Street 5-1-24 DP. Silt fence has been installed. Still needing the intersection of SW Mary and Redbuck Cir cleaned up. 5-2-24 Dustin A, Intersection has been cleaned
Sidewalk Inspection Partial 6/7/2024 6/7/2024 06/07/2024
Misc
Informational
06/07/2024
6-7-24 Dustin A, SW is formed to city specs and slopes are in compliance. Approved to pour
Erosion Control Inspection Residential Failed 07/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/10/2024
-Clean silt from sidewalk and streets
Plot Plan Inspection Failed 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/10/2024
-Complete final grade and sod -Unable to locate water meter -Unable to locate sewer tracer wire box
Occupancy Inspection - Codes Residential Failed 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/10/2024
-Clean mud from sidewalk and street before any further inspection -Complete final grade and sod -Unable to locate sewer tracer wire or water meter -Obtain lawn irrigation permit -Sidewalk inspection still pending -Gaurdrail at garage to be min of 36" -Secure gaurdrail at garage to withstand 250 lbs linear force -Label non GFCI receptacle at garage -Provide (2) 3" screws at each hinge location and strike plate at back door per LS security code -Provide graspable handrail at max 38" height at back stairs -Stair risers over 7.75" and vary greater than 3/8" at basement stairs -Support expansion tank at water heater -Provide AGCI protection at dishwasher -Provide AFCI protection at breakers labeled "kitchen GFCI 1 and 2" -Install 5/8" sheet rock under stairs to garage and fireblock gaps
Erosion Control Inspection Residential Failed 7/11/2024 07/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/11/2024
-Clean silt from sidewalk and streets
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/11/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Ready for Temp CO 7/11/2024 7/11/2024 07/11/2024
Misc
Corrective Action Required
07/10/2024
- Provide as graded plot plan -Complete final grade and sod -Unable to locate sewer tracer wire, land at grade -Obtain lawn irrigation permit -Sidewalk inspection still pending - Pay all fees
Erosion Control Inspection Residential Passed 7/16/2024 07/16/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/16/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 7/16/2024 07/16/2024
Misc
Resolved
07/16/2024
Sidewalk Inspection Passed 7/19/2024 7/19/2024 07/19/2024
Misc
Informational
07/19/2024
7-19-24 DP sidewalk has passed.
Occupancy Inspection - Codes Residential Full C of O 7/19/2024 7/19/2024 07/19/2024
Misc
Resolved
07/19/2024
Documents & Images
Date Uploaded File Type Document Name
09/22/2023 Lot 100 Permit Application
09/22/2023 Lot 100 Excise Tax Form
09/22/2023 Blue Prints Lot 100 Full Set
09/26/2023 Approved Plans APPROVED PLANS
09/26/2023 Permit Codes Residential Plan Review
10/16/2023 Permit Codes Residential Plan Review
10/17/2023 Plot Plan APPROVED PLOT PLAN
10/17/2023 Permit Codes Residential Plan Review
10/18/2023 Permit DS Building Permit
10/18/2023 Receipt Receipt for transaction: 2023-007845
10/21/2023 M L Crose 3233 SW Mary St LSMO Footing Inspection Report 10-20-23
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter Stop Work Order
10/26/2023 Letter INSPECTION SUMMARY
10/27/2023 Letter INSPECTION SUMMARY
11/27/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/02/2024 Letter INSPECTION SUMMARY
06/07/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/11/2024 Receipt Receipt for transaction:2024-005707
07/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/11/2024 Receipt Receipt for transaction:2024-005708
07/15/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
07/16/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter Field Certificate of Occupancy
07/19/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home