Permit Application Status

PRRES20233692


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233692
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
07/31/2023
08/07/2023
01/30/2024
04/19/2024
Locations
Contacts
SAB CONSTRUCTION LLC, Address:200 NW COMMERCE CT  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
JOE@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Zack Bryant, Address:200 NW Commerce CT  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 08/07/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/07/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/07/2023
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 08/07/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 08/07/2023
9110078-Valuation Fee New Single Family $1,715.95 $1,715.95 Paid 08/07/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/22/2023 08/22/2023
Underslab Plumbing Inspection - Residential Passed 8/22/2023 8/22/2023 08/22/2023
Sewer Service Inspection - R Passed 8/28/2023 (8:15) 8/28/2023 08/28/2023
Water Service Inspection - R Passed 8/29/2023 (10:30) 8/29/2023 08/29/2023
Piers/Caissons Inspection - Residential Passed 9/5/2023 (9:00) 9/5/2023 09/05/2023
All Rough Inspection - Residential Partial 10/13/2023 10/13/2023 10/13/2023
Misc
Corrective Action Required
10/13/2023
Garage portal frame only inspected
Electrical Service Inspection Passed 12/5/2023 12/05/2023
Erosion Control Inspection Residential Failed 12/5/2023 12/05/2023
Misc
Corrective Action Required
12/05/2023
- No pressure on gauge - gas line not bonded
Erosion Control Inspection Residential Failed 12/5/2023 12/05/2023
Misc
Corrective Action Required
12/05/2023
- Repair silt fence - Remove gravel and debris from street - clean storm inlet at front of lot
All Rough Inspection - Residential Failed 12/5/2023 12/5/2023 12/05/2023
Misc
Informational
12/05/2023
Garage portal frame only inspected
Misc
Corrective Action Required
12/05/2023
- Anchor bolts to be middle third of plate @ portal frame garage - Fire block top plate garage/ laundry wall - Solid bock sheeting breaks in dining room - Fire block top plate garage B-vent chase - Security blocking to be 3 stud bays at dining to deck - Fire blocking at chase top plate shall continue to edge of sheet rock entry bath tub - Strap top plate, not tied in. Master/ Great room - Solid block sheeting breaks master bedroom - Security blocking to be 3 stud bays deck door in master bedroom - Missing nails in double joist hanger at south east corner great room - Purlin struts to be 4’ O C. - Minimum of 3 suds on exterior corners required at basement bedroom 3 and family room South west corner - Address over notched studs basement bedroom 3 and family room South wall - Fire block return air basement bedroom 4 - Fire block top plate at basement bathroom tub chase
Gas Service Inspection - Residential Failed 12/5/2023 12/05/2023
Misc
Corrective Action Required
12/05/2023
- no pressure on gauge - gas line not bonded
All Rough Inspection - Residential Passed 12/13/2023 12/13/2023 12/13/2023
Misc
Resolved
12/13/2023
Garage portal frame only inspected
Misc
Resolved
12/13/2023
- Anchor bolts to be middle third of plate @ portal frame garage - Fire block top plate garage/ laundry wall - Solid bock sheeting breaks in dining room - Fire block top plate garage B-vent chase - Security blocking to be 3 stud bays at dining to deck - Fire blocking at chase top plate shall continue to edge of sheet rock entry bath tub - Strap top plate, not tied in. Master/ Great room - Solid block sheeting breaks master bedroom - Security blocking to be 3 stud bays deck door in master bedroom - Missing nails in double joist hanger at south east corner great room - Purlin struts to be 4’ O C. - Minimum of 3 suds on exterior corners required at basement bedroom 3 and family room South west corner - Address over notched studs basement bedroom 3 and family room South wall - Fire block return air basement bedroom 4 - Fire block top plate at basement bathroom tub chase
Erosion Control Inspection Residential Failed 12/13/2023 12/13/2023
Misc
Corrective Action Required
12/05/2023
- Repair silt fence - Remove gravel and debris from street - clean storm inlet at front of lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 12/14/2023 12/14/2023 12/14/2023
Misc
Resolved
12/14/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
12/14/2023
Gas Service Inspection - Residential Not Ready 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/05/2023
- gas line not bonded
Gas Service Inspection - Residential Passed 12/28/2023 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
Sidewalk Inspection Partial 2/22/2024 2/22/2024 02/22/2024
Misc
Informational
02/22/2024
2-22-24 PS Performed sidewalk pre pour inspection, forms in place and aggregate compacted, approved to pour
Driveway Inspection Partial 2/22/2024 2/22/2024 02/22/2024
Misc
Informational
02/22/2024
2-22-24 PS Performed driveway approach pre pour inspection, forms in place and aggregate compacted, approved to pour
Plot Plan Inspection Passed 4/12/2024 04/12/2024
Occupancy Inspection - Codes Residential Failed 4/12/2024 4/12/2024 04/12/2024
SEC. 7-1403 PREMISES IDENTIFICATION
Corrective Action Required
04/12/2024
Approved numbers or addresses shall be provided for all new dwelling unit structures in such a position as to be plainly visible and legible from the street or road fronting the property. Each dwelling unit within a multiple dwelling unit structure shall be identified at the main entry with premises identification unique to each dwelling unit. Residential dwelling units and structures housing multiple dwelling units accessed by private drive(s) or parking lot(s) shall also provide approved numbers or addresses in such a position as to be plainly visible and legible from such drive(s) or parking lot(s). Approved numbers or address characters shall be a minimum height of 4 inches (76 mm) and minimum stroke of 0.5 inches (12.7 mm). Approved numbers or address characters shall be of a contrasting color to the background itself.
Misc
Corrective Action Required
04/12/2024
- pending final Driveway inspection - Pending final sidewalk inspection - Pay outstanding fees - Sump discharge to be more than 36” away from foundation - Seal exterior penetrations at line set - GFCI outlet on deck not working - Provide 3” screws on exterior door hinges (2) per hinge per security ordinance - Master bathroom not inspected, wet paint and sealed off.
Driveway Inspection Passed 4/18/2024 4/18/2024 04/18/2024
Misc
Informational
02/22/2024
2-22-24 PS Performed driveway approach pre pour inspection, forms in place and aggregate compacted, approved to pour 4-18-24 Dustin A, DW is poured to city specs, Passed
Sidewalk Inspection Passed 4/18/2024 4/18/2024 04/18/2024
Misc
Informational
02/22/2024
2-22-24 PS Performed sidewalk pre pour inspection, forms in place and aggregate compacted, approved to pour 4-18-24 Dustin A, Sw is poured to city specs, passed
Occupancy Inspection - Codes Residential Full C of O 4/19/2024 4/19/2024 04/19/2024
SEC. 7-1403 PREMISES IDENTIFICATION
Resolved
04/19/2024
Approved numbers or addresses shall be provided for all new dwelling unit structures in such a position as to be plainly visible and legible from the street or road fronting the property. Each dwelling unit within a multiple dwelling unit structure shall be identified at the main entry with premises identification unique to each dwelling unit. Residential dwelling units and structures housing multiple dwelling units accessed by private drive(s) or parking lot(s) shall also provide approved numbers or addresses in such a position as to be plainly visible and legible from such drive(s) or parking lot(s). Approved numbers or address characters shall be a minimum height of 4 inches (76 mm) and minimum stroke of 0.5 inches (12.7 mm). Approved numbers or address characters shall be of a contrasting color to the background itself.
Misc
Resolved
04/19/2024
- pending final Driveway inspection - Pending final sidewalk inspection - Pay outstanding fees - Sump discharge to be more than 36” away from foundation - Seal exterior penetrations at line set - GFCI outlet on deck not working - Provide 3” screws on exterior door hinges (2) per hinge per security ordinance - Master bathroom not inspected, wet paint and sealed off.
Documents & Images
Date Uploaded File Type Document Name
07/31/2023 HF120 - Air Combustion Calc
07/31/2023 HF120 - Excise Tax Application
07/31/2023 HF120 - Final Plot Plan 7_31_23
07/31/2023 HF120 - Permit Application
07/31/2023 HF120 - Final Engineered Plans 7_31_23
08/03/2023 Permit Codes Residential Plan Review
08/03/2023 Approved Plans approved plans
08/07/2023 LOT 120 CITY
08/07/2023 Permit Codes Residential Plan Review
08/07/2023 Plot Plan approved plot plan
08/07/2023 Permit DS Building Permit
08/07/2023 Receipt Receipt for transaction:2023-006083
08/11/2023 M L Crose 2626 SW Tracker LN LSMO Hook Farms Lot 120 Footing Inspection Report 8-11-23
08/22/2023 Letter INSPECTION SUMMARY
08/22/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/05/2023 Letter INSPECTION SUMMARY
10/13/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/05/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
02/22/2024 Letter INSPECTION SUMMARY
04/12/2024 Letter INSPECTION SUMMARY
04/12/2024 Letter INSPECTION SUMMARY
04/18/2024 Receipt Receipt for transaction:2024-002476
04/18/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter Field Certificate of Occupancy
04/19/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home