Permit Application Status

PRRES20233614


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233614
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX. UNFINISHED BASEMENT. ROOF TRUSSES.
07/26/2023
08/04/2023
01/27/2024
11/01/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,216.60 $2,216.60 Paid 08/04/2023
Water Tap Fee $7,520.00 $7,520.00 Paid 08/04/2023
Water Meter Fee $1,360.92 $1,360.92 Paid 08/04/2023
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 08/04/2023
Right of Way Permit Fee $85.00 $85.00 Paid 08/04/2023
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 08/04/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 04/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/18/2023 08/18/2023
Miscellaneous Correction
Informational
08/18/2023
Footing inspection was passed by a third party. Piers were not addressed by the third party.
Sewer Service Inspection - R Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Informational
08/29/2023
2136 sewer passed. This is a partial pass only. 2134 will be called in at a later date
Water Service Inspection - R Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Corrective Action Required
08/29/2023
Water line at 2136 passed to the corner of the garage only. This is a partial pass so the water line can be covered with dirt to the corner of the home only. The other half of 2136 and all of 2134 will be called in for inspection at a later date. This is a partial to a partial pass only.
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full erosion control must be in place until and maintained until CO. Remove and dirt or gravel from the street. Erosion control must be in place before any inspections can be completed, 08/29/2023 KBEARD
Sewer Service Inspection - R Passed 8/30/2023 (11:00) 8/30/2023 08/30/2023
Miscellaneous Correction
Resolved
08/30/2023
2136 sewer passed. This is a partial pass only. 2134 will be called in at a later date
Underslab Plumbing Inspection - Residential Passed 8/30/2023 8/30/2023 08/30/2023
Water Service Inspection - R Passed 8/31/2023 (10:45) 8/31/2023 08/31/2023
Miscellaneous Correction
Resolved
08/31/2023
Water line at 2136 passed to the corner of the garage only. This is a partial pass so the water line can be covered with dirt to the corner of the home only. The other half of 2136 and all of 2134 will be called in for inspection at a later date. This is a partial to a partial pass only.
Erosion Control Inspection Residential Failed 10/26/2023 10/26/2023
Miscellaneous Correction
Resolved
10/26/2023
Full erosion control must be in place until and maintained until CO. Remove and dirt or gravel from the street. Erosion control must be in place before any inspections can be completed, 08/29/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/26/2023
Erosion control is missing or has been torn down. Full erosion control must be maintained until occupancy.
All Rough Inspection - Residential Partial 2/2/2024 02/02/2024
Miscellaneous Correction
Informational
02/02/2024
Portal inspections passed
All Rough Inspection - Residential Failed 2/6/2024 2/6/2024 02/06/2024
Miscellaneous Correction
Informational
02/02/2024
Portal inspections passed
Miscellaneous Correction
Corrective Action Required
02/06/2024
2134 SW Osage all rough Chase between garage and bedroom 2 needs to be fire blocked at the ceiling GT stud pack in garage and bedroom 1 is missing Gang plate in pantry truss is damaged Joist hangers missing in bedroom 2 ceiling Upper stair case does not bear 1 1/2 inches on support at platform Blocking is missing in one space above the support Ibeam in the basement Roof boots are not installed 2136 Ceiling joist hangers are not installed in bedroom 2 GT stud pack missing in garage to bedroom 2 GT stud pack is missing one stud in bedroom 1 Upper stair case does not bear 1 1/2 inches on support at platform Plywood decking is within 4 feet of fire wall Nail all exterior sheeting along the bottom plate 6 inches on center on both units
Gas Service Inspection - Residential Passed 2/6/2024 02/06/2024
Electrical Service Inspection Passed 2/6/2024 02/06/2024
Rated Assembly Inspection Failed 2/6/2024 02/06/2024
Miscellaneous Correction
Corrective Action Required
02/06/2024
2136 Plywood decking is within 4 feet of fire wall
Erosion Control Inspection Residential Partial 2/6/2024 02/06/2024
Miscellaneous Correction
Resolved
02/06/2024
Erosion control is missing or has been torn down. Full erosion control must be maintained until occupancy.
Miscellaneous Correction
Informational
02/06/2024
Erosion control measures are in place at the time of all rough. Full erosion control must be maintained until CofO
All Rough Inspection - Residential Passed 2/8/2024 2/8/2024 02/08/2024
Miscellaneous Correction
Informational
02/06/2024
Portal inspections passed
Miscellaneous Correction
Resolved
02/08/2024
2134 SW Osage all rough Chase between garage and bedroom 2 needs to be fire blocked at the ceiling GT stud pack in garage and bedroom 1 is missing Gang plate in pantry truss is damaged Joist hangers missing in bedroom 2 ceiling Upper stair case does not bear 1 1/2 inches on support at platform Blocking is missing in one space above the support Ibeam in the basement Roof boots are not installed 2136 Ceiling joist hangers are not installed in bedroom 2 GT stud pack missing in garage to bedroom 2 GT stud pack is missing one stud in bedroom 1 Upper stair case does not bear 1 1/2 inches on support at platform Plywood decking is within 4 feet of fire wall Nail all exterior sheeting along the bottom plate 6 inches on center on both units
Driveway Inspection Partial 2/28/2024 02/28/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A, Dw is formed and aggregate is compacted. Approved to pour
Sidewalk Inspection Partial 2/28/2024 02/28/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A,Sw is formed to city specs. Approved to pour
Driveway Inspection Partial 3/6/2024 3/6/2024 02/28/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A, Dw is formed and aggregate is compacted. Approved to pour
Sidewalk Inspection Passed 3/6/2024 3/6/2024 03/04/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A,Sw is formed to city specs. Approved to pour 3-4-24 Dustin A, Sw is poured to city specs, Passed
Driveway Inspection Passed 3/6/2024 3/6/2024 03/04/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A, Dw is formed and aggregate is compacted. Approved to pour 3-4-24 Dustin A, Dw is poured to city specs. Passed
Erosion Control Inspection Residential Partial 3/14/2024 03/14/2024
Miscellaneous Correction
Informational
02/06/2024
Erosion control measures are in place at the time of all rough. Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 3/28/2024 3/28/2024 03/28/2024
Miscellaneous Correction
Corrective Action Required
03/28/2024
2134 SW Osage. Occupancy address numbers are not properly illuminated Smoke detectors need plastic cover’s removed Exterior of house is not ready for inspection 2136 is not ready for inspection
Erosion Control Inspection Residential Failed 4/1/2024 04/01/2024
Miscellaneous Correction
Informational
03/14/2024
Erosion control measures are in place at the time of all rough. Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
04/01/2024
Both units needs silt fence installed at the front of the property by the street and unit 2134’s east side. Full erosion control must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 4/2/2024 4/2/2024 04/02/2024
Miscellaneous Correction
Resolved
04/02/2024
2134 SW Osage. Occupancy address numbers are not properly illuminated Smoke detectors need plastic cover’s removed Exterior of house is not ready for inspection 2136 is not ready for inspection
Miscellaneous Correction
Corrective Action Required
04/02/2024
Exterior of house is not ready for inspection 2136 is not ready for inspection Exterior of both units are not ready for inspection 2134 Passed for TCO This is a partial pass for TCO only
Rated Assembly Inspection Passed 4/2/2024 4/2/2024 04/02/2024
Miscellaneous Correction
Resolved
04/02/2024
2136 Plywood decking is within 4 feet of fire wall
Plot Plan Inspection Failed 4/15/2024 04/15/2024
Miscellaneous Correction
Corrective Action Required
04/15/2024
-As graded plot plan was not submitted before the installation of sod. -As graded plot plan needs to be submitted
Occupancy Inspection - Codes Residential Failed 4/15/2024 4/15/2024 04/15/2024
Miscellaneous Correction
Corrective Action Required
04/02/2024
Exterior of house is not ready for inspection 2136 is not ready for inspection Exterior of both units are not ready for inspection 2134 Passed for TCO This is a partial pass for TCO only
Miscellaneous Correction
Corrective Action Required
04/15/2024
2136 SW Osage. Occupancy •Part of basement ceiling has less than the required 6’8” clear ceiling height -electrical lines are exposed in the basement bathroom at the light fixture •Electrical outlets in kitchen are not fully installed •Back porch security light is lower than the required 8 foot height •Hot water heater breaker needs to have a lock out installed •Siding at gas line needs to be sealed •Electrical disconnect panels will be lock shut 2134 •water meter is covered by sod Plot plan must pass on both sides. Sod was installed before the required as graded plot plan was supposed to be submitted
Occupancy Inspection - Codes Residential Ready for Temp CO 4/17/2024 4/17/2024 04/17/2024
Miscellaneous Correction
Resolved
04/17/2024
Exterior of house is not ready for inspection 2136 is not ready for inspection Exterior of both units are not ready for inspection 2134 Passed for TCO This is a partial pass for TCO only
Miscellaneous Correction
Resolved
04/17/2024
2136 SW Osage. Occupancy •Part of basement ceiling has less than the required 6’8” clear ceiling height -electrical lines are exposed in the basement bathroom at the light fixture •Electrical outlets in kitchen are not fully installed •Back porch security light is lower than the required 8 foot height •Hot water heater breaker needs to have a lock out installed •Siding at gas line needs to be sealed •Electrical disconnect panels will be lock shut 2134 •water meter is covered by sod Plot plan must pass on both sides. Sod was installed before the required as graded plot plan was supposed to be submitted
Miscellaneous Correction
Informational
04/17/2024
2134 •water meter is covered by sod Plot plan must pass on both sides. Sod was installed before the required as graded plot plan was supposed to be submitted Both units 2134 and 2136 passed for TCO only
Occupancy Inspection - Codes Residential Failed 5/20/2024 05/20/2024
Miscellaneous Correction
Resolved
05/20/2024
2134 •water meter is covered by sod Plot plan must pass on both sides. Sod was installed before the required as graded plot plan was supposed to be submitted Both units 2134 and 2136 passed for TCO only
Miscellaneous Correction
Corrective Action Required
05/20/2024
2134 Water meter is covered by sod Plot plan must pass on both sides. Sod was installed before the required as graded plot plan was supposed to be submitted
Plot Plan Inspection Passed 6/11/2024 06/11/2024
Miscellaneous Correction
Resolved
06/11/2024
-As graded plot plan was not submitted before the installation of sod. -As graded plot plan needs to be submitted
Erosion Control Inspection Residential Passed 06/14/2024
Miscellaneous Correction
Resolved
06/14/2024
Erosion control measures are in place at the time of all rough. Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
06/14/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Resolved
06/14/2024
Both units needs silt fence installed at the front of the property by the street and unit 2134’s east side. Full erosion control must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 6/14/2024 6/14/2024 06/14/2024
Miscellaneous Correction
Corrective Action Required
05/20/2024
2134 Water meter is covered by sod
Occupancy Inspection - Codes Residential Full C of O 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
2134 Water meter is covered by sod
Documents & Images
Date Uploaded File Type Document Name
07/26/2023 OS #56 - PERMIT APP
07/28/2023 Permit Codes Residential Plan Review
07/31/2023 Plot Plan APPROVED PLOT PLAN
08/03/2023 Approved Plans APPROVED TRUSS PACKAGE
08/03/2023 Approved Plans APPROVED PLANS
08/03/2023 Approved Plans APPROVED TRUSS LAYOUT
08/03/2023 Permit Codes Residential Plan Review
08/04/2023 Permit DS Building Permit
08/04/2023 Receipt Receipt for transaction:2023-006053
08/18/2023 2134 & 2136 SW Osage Dr LSMO Osage Lot 56 Footing Inspection Report
08/18/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/31/2023 Letter INSPECTION SUMMARY
10/26/2023 Letter INSPECTION SUMMARY
02/02/2024 Letter INSPECTION SUMMARY
02/02/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/18/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/18/2024 Receipt Receipt for transaction:2024-002478
05/20/2024 Letter INSPECTION SUMMARY
06/10/2024 LOT 56 ASBUILT
06/10/2024 Plot Plan approved as graded plot plan
06/11/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter Codes Residential Plan Review
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter Field Certificate of Occupancy
11/01/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home