NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
07/14/2023
07/20/2023
01/15/2024
05/29/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/20/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/20/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/20/2023
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 07/20/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 07/20/2023
9110078-Valuation Fee New Single Family $1,757.45 $1,757.45 Paid 07/20/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/23/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/29/2024 08/08/2023
Water Service Inspection - R Partial 8/11/2023 8/11/2023 08/11/2023
Sewer Service Inspection - R Passed 8/11/2023 8/11/2023 08/11/2023
Water Service Inspection - R Passed 8/14/2023 (9:00) 8/14/2023 08/14/2023
Underslab Plumbing Inspection - Residential Passed 8/17/2023 8/17/2023 08/17/2023
All Rough Inspection - Residential Not Ready 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/21/2023
No access no lockbox present garage doors and front door locked
Electrical Service Inspection Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/21/2023
No access no lockbox present garage doors and front door locked
Gas Service Inspection - Residential Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/21/2023
No access no lockbox present garage doors and front door locked
All Rough Inspection - Residential Failed 12/28/2023 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
Misc
Corrective Action Required
12/28/2023
-Missing large anchor bolts on either side of main garage door -Provide rafter to ceiling joist connections throughout -Missing nail plates at left wall bedroom 2 -Missing collar ties above deck area -Remove sheathing at deck ceiling for inspection -Loose 2x4 at fireplace left side -Missing fire blocking in chimney chase at top -Provide 1inch clearance at fireplace flue -Fire blocking at flue chase from master bedroom and attic space -Nail exterior corner of master bedroom closet per code -Fireblock at furred out wall in bedroom 3 closet -Provide clearance for pex line at ceiling near light fixture in basement bathroom -Missing studs at LVL corner near entry -Install purlin at laundry room above east wall per plans -Missing anchor bolts on right side of sliding door in basement -Seal supply heat duct through return air at bottom of stairs -Complete framing at exterior corner walls in basement -Install 2x12 at valley over fireplace per plan -Missing 1/2 inch through bolts at post to beam connections at deck
Electrical Service Inspection Passed 12/28/2023 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
Gas Service Inspection - Residential Failed 12/28/2023 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
Misc
Corrective Action Required
12/28/2023
-Provide bonding for CSST
Gas Service Inspection - Residential Passed 1/18/2024 1/18/2024 01/18/2024
Misc
Resolved
01/18/2024
All Rough Inspection - Residential Failed 1/18/2024 1/18/2024 01/18/2024
Misc
Partial Correction
01/18/2024
-Complete framing at exterior corner walls in basement
All Rough Inspection - Residential Passed 1/25/2024 1/25/2024 01/25/2024
Misc
Resolved
01/25/2024
Driveway Inspection Partial 3/4/2024 03/04/2024
Misc
Informational
03/04/2024
3-4-24 Dustin A, dw is formed and compacted to city specs. Approved to pour
Driveway Inspection Passed 3/11/2024 3/11/2024 03/11/2024
Misc
Informational
03/04/2024
3-4-24 Dustin A, dw is formed and compacted to city specs. Approved to pour 3-11-24 Dustin A, Dw is poured to city specs. Passed
Sidewalk Inspection Partial 4/10/2024 4/10/2024 04/10/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, SW formed to city specs, Approved to pour.
Sidewalk Inspection Passed 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, SW formed to city specs, Approved to pour. 4-17-24 Dustin A. SW is poured to city specs, Passed
Erosion Control Inspection Residential Passed 5/29/2024 04/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Failed 5/29/2024 05/23/2024
Misc
Corrective Action Required
05/23/2024
As graded plot plan required to be submitted and approved PRIOR to sod
Occupancy Inspection - Codes Residential Not Ready 5/23/2024 5/23/2024 05/23/2024
Misc
Corrective Action Required
05/23/2024
**House not ready for occupancy. No inspection performed. List is incomplete. Correct all of the following before re inspection: -Open electrical boxes at front -Illuminated address at front required -Remove all material to access garage receptacles and panel -Garage door must self close and latch
Occupancy Inspection - Codes Residential Failed 5/24/2024 5/24/2024 05/24/2024
Misc
Corrective Action Required
05/23/2024
-provide as graded plot plan -Garage door must self close and latch -identify sewer tracer wire -spark rings at basement wet bar outlets -install flood light at rear -will check outside items at re inspection, water meter, penetrations, tamper caps for A/c, exc(sprinklers going off during inspection)
Occupancy Inspection - Codes Residential Full C of O 5/29/2024 5/29/2024 05/29/2024
Misc
Resolved
05/29/2024
-provide as graded plot plan -Garage door must self close and latch -identify sewer tracer wire -spark rings at basement wet bar outlets -install flood light at rear -will check outside items at re inspection, water meter, penetrations, tamper caps for A/c, exc(sprinklers going off during inspection)
Plot Plan Inspection Passed 05/29/2024
Misc
Resolved
05/29/2024
As graded plot plan required to be submitted and approved PRIOR to sod
Erosion Control Inspection Residential Passed 05/29/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/29/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Documents & Images
Date Uploaded File Type Document Name
07/14/2023 2747 SW Heartland Signed City Application
07/14/2023 LOT 189 FINAL SURVEY
07/14/2023 RHF189 Spec - Sealed Plans (July 14, 2023) (1)
07/19/2023 Permit Codes Residential Plan Review
07/19/2023 Approved Plans approved plans
07/20/2023 LOT 189 CITY UPDATED
07/20/2023 Permit Codes Residential Plan Review
07/20/2023 Plot Plan approved plot plan
07/20/2023 Permit DS Building Permit
07/20/2023 Receipt Receipt for transaction:2023-005633
08/04/2023 Wilmoth 2747 SW Heartland Rd LSMO Hook Farms Lot 189 Footing Inspection Report 8-3-23
08/08/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter INSPECTION SUMMARY
08/17/2023 Letter INSPECTION SUMMARY
09/15/2023 Final_2023_08_29_DPier_LSMO_Pat Cochran Concrete
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
01/18/2024 Letter INSPECTION SUMMARY
01/18/2024 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
05/23/2024 Receipt Receipt for transaction:2024-003944
05/24/2024 Letter INSPECTION SUMMARY
05/28/2024 LOT 189 ASBUILT
05/29/2024 Letter Field Certificate of Occupancy
05/29/2024 Letter Codes Final Certificate of Occupancy
05/29/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home