Summary
PRRES20233098
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT- COVERED AND UNCOVERED DECK
06/28/2023
07/12/2023
12/30/2023
11/10/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
United Heating & Cooling, Address:301 Duck Rd, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/12/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/12/2023
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/12/2023
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 07/12/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 07/12/2023
9110078-Valuation Fee New Single Family $1,365.61 $1,365.61 Paid 07/12/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/09/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/17/2023 (11:00) 7/17/2023 07/17/2023
Piers/Caissons Inspection - Residential Passed 7/17/2023 07/17/2023
Misc
Informational
07/17/2023
Five piers for the back porch/deck were poured at the same time as the footing
Sewer Service Inspection - R Passed 7/26/2023 (1:15) 7/26/2023 07/26/2023
Water Service Inspection - R Passed 7/27/2023 (1:30) 7/27/2023 07/27/2023
Underslab Plumbing Inspection - Residential Passed 7/28/2023 7/27/2023 07/27/2023
Erosion Control Inspection Residential Failed 7/27/2023 07/27/2023
Miscellaneous Correction
Corrective Action Required
07/27/2023
Full perimeter erosion control including the pile of dirt on the west lot needs to be in place. No inspections shall be conducted until erosion control measures are installed 07/27/2023. KBEARD
Erosion Control Inspection Residential Partial 8/4/2023 08/04/2023
Miscellaneous Correction
Resolved
08/04/2023
Full perimeter erosion control including the pile of dirt on the west lot needs to be in place. No inspections shall be conducted until erosion control measures are installed 07/27/2023. KBEARD
Miscellaneous Correction
Informational
08/04/2023
Erosion control is in place as of 08/04/2023 and needs to be maintained until full C of O
All Rough Inspection - Residential Not Ready 8/25/2023 8/25/2023 08/25/2023
Miscellaneous Correction
Corrective Action Required
08/25/2023
- No sealed plans were let in the house -,Contractor still working inside the house - There are no accommodations for a requested PM inspection. The city is under an excessive heat warning - Only request inspections when ready. Walk your project and make sure it is ready for inspection 08/25/2023 KBEARD 8:20am
Gas Service Inspection - Residential Failed 8/25/2023 8/28/2023 08/28/2023
Miscellaneous Correction
Corrective Action Required
08/28/2023
-Gas line needs to be bonded -Gas line to fireplace is not connected or properly secured
Electrical Service Inspection Passed 8/25/2023 8/28/2023 08/28/2023
All Rough Inspection - Residential Failed 8/28/2023 8/28/2023 08/28/2023
Miscellaneous Correction
Resolved
08/28/2023
- No sealed plans were let in the house -,Contractor still working inside the house - There are no accommodations for a requested PM inspection. The city is under an excessive heat warning - Only request inspections when ready. Walk your project and make sure it is ready for inspection 08/25/2023 KBEARD 8:20am
Miscellaneous Correction
Corrective Action Required
08/28/2023
1804 first rough inspection - Anchor bolts not tightened down in the garage bottom plate - Nut missing in garage for anchor plate tie down - Truss tie down screw missing in garage - Electrical outlet in garage is over 66 inches high and needs to be lowered - Electrical outlet in the utility room is set back to far in the cavity wall - BOCA plate not installed in the utility room - Corners in the house need to be nailed off 12 inches on center - Double truss in bedroom 1 closet does not have a tie down screws - Bedroom 1 is missing truss tie down screws - Top plate throughout needs to be fire blocked, this includes top plate extensions - Fire place insert is not finished and gas line is not secured - Truss tie down screws are missing in the great room - LIB in kitchen is not fully attached - Electrical outlet is missing at the stairs on the main floor - Truss tie down screws are missing above the front entrance door - Front entry LIB needs two nails per stud - LIB in owners entrance is not completely nailed off - LIB’s in bedroom 2 is not completely nailed off - LIB in bedroom 3 is not completely nailed off - LIB is not installed in bathroom 2 - Truss tie down screws are missing on back porch - Air supply line to bedroom 1 in basement is over 10 feet long and needs to be braced - Anchor bolt is missing in the basement N/E corner - Anchor bolts nut’s missing along the east wall in basement - Gas line is not bonded - Basement bottom plate anchor bolts are not located in the middle 1/3 of the board - Address double LVL in basement between stair and concrete west wall that rest on a flat 2x4 and is not properly supported - Joist hangers under back deck are missing nails - Post to beam under back deck needs two all threads per post at each connection - Siding along North wall needs to be nailed every 6 inches on center at bottom plate
All Rough Inspection - Residential Failed 8/30/2023 8/30/2023 08/30/2023
Miscellaneous Correction
Resolved
08/30/2023
1804 first rough inspection - Anchor bolts not tightened down in the garage bottom plate - Nut missing in garage for anchor plate tie down - Truss tie down screw missing in garage - Electrical outlet in garage is over 66 inches high and needs to be lowered - Electrical outlet in the utility room is set back to far in the cavity wall - BOCA plate not installed in the utility room - Corners in the house need to be nailed off 12 inches on center - Double truss in bedroom 1 closet does not have a tie down screws - Bedroom 1 is missing truss tie down screws - Top plate throughout needs to be fire blocked, this includes top plate extensions - Fire place insert is not finished and gas line is not secured - Truss tie down screws are missing in the great room - LIB in kitchen is not fully attached - Electrical outlet is missing at the stairs on the main floor - Truss tie down screws are missing above the front entrance door - Front entry LIB needs two nails per stud - LIB in owners entrance is not completely nailed off - LIB’s in bedroom 2 is not completely nailed off - LIB in bedroom 3 is not completely nailed off - LIB is not installed in bathroom 2 - Truss tie down screws are missing on back porch - Air supply line to bedroom 1 in basement is over 10 feet long and needs to be braced - Anchor bolt is missing in the basement N/E corner - Anchor bolts nut’s missing along the east wall in basement - Gas line is not bonded - Basement bottom plate anchor bolts are not located in the middle 1/3 of the board - Address double LVL in basement between stair and concrete west wall that rest on a flat 2x4 and is not properly supported - Joist hangers under back deck are missing nails - Post to beam under back deck needs two all threads per post at each connection - Siding along North wall needs to be nailed every 6 inches on center at bottom plate
Miscellaneous Correction
Corrective Action Required
08/30/2023
Fire place insert is not installed. Call back in for all rough before insulation and sheet rock around fire place Exterior deck stairway going under the deck R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. This item can be inspected at occupancy. Okay to insulate and rock the interior except for the fireplace 08/30/2023 KBEARD
Gas Service Inspection - Residential Failed 8/30/2023 8/30/2023 08/30/2023
Miscellaneous Correction
Corrective Action Required
08/28/2023
-Gas line to fireplace is not connected or properly secured Okay to insulate and sheetrock 08/30/2023 KBEARD
Erosion Control Inspection Residential Partial 9/8/2023 09/08/2023
Miscellaneous Correction
Informational
08/04/2023
Erosion control is in place as of 08/04/2023 and needs to be maintained until full C of O
Miscellaneous Correction
Partial Correction
09/08/2023
Erosion control is in place at the time of this inspection
Gas Service Inspection - Residential Passed 9/8/2023 9/8/2023 09/08/2023
Miscellaneous Correction
Resolved
09/08/2023
-Gas line to fireplace is not connected or properly secured Okay to insulate and sheetrock 08/30/2023 KBEARD
All Rough Inspection - Residential Failed 9/8/2023 9/8/2023 09/08/2023
Miscellaneous Correction
Corrective Action Required
08/30/2023
Exterior deck stairway going under the deck R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. This item can be inspected at occupancy. Okay to insulate and rock the interior 08/30/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
09/08/2023
Exterior deck stairway going under the deck R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. Head room is 6 foot 3 inches measured vertically from the sloped line adjoining the (tread nosing) to the patio rim board going under the stairs. Piers were also installed without an inspection and can not be varified for approval.
All Rough Inspection - Residential Passed 9/14/2023 9/14/2023 09/14/2023
Miscellaneous Correction
Resolved
09/14/2023
Exterior deck stairway going under the deck R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. This item can be inspected at occupancy. Okay to insulate and rock the interior 08/30/2023 KBEARD
Miscellaneous Correction
Resolved
09/14/2023
Exterior deck stairway going under the deck R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. Head room is 6 foot 3 inches measured vertically from the sloped line adjoining the (tread nosing) to the patio rim board going under the stairs. Piers were also installed without an inspection and can not be varified for approval.
Driveway Inspection Partial 9/18/2023 9/18/2023 09/18/2023
Misc
Informational
09/18/2023
9-18-23 PS Performed driveway approach pre pour, forms in place and aggregate compacted. OK to pour
Sidewalk Inspection Partial 9/18/2023 9/18/2023 09/18/2023
Misc
Informational
09/18/2023
9-18-23 PS Performed sidewalk pre pour inspection, forms in place and aggregate compacted. OK to pour
Driveway Inspection Passed 9/25/2023 9/25/2023 09/25/2023
Misc
Informational
09/18/2023
9-18-23 PS Performed driveway approach pre pour, forms in place and aggregate compacted. OK to pour 9-25-23 PS Driveway approach meets LS and ADA specs
Sidewalk Inspection Passed 9/25/2023 9/25/2023 09/25/2023
Misc
Informational
09/18/2023
9-18-23 PS Performed sidewalk pre pour inspection, forms in place and aggregate compacted. OK to pour 9-25-23 PS Sidewalk meets ADA and LS specs
Erosion Control Inspection Residential Failed 10/26/2023 10/26/2023
Miscellaneous Correction
Informational
09/08/2023
Erosion control is in place as of 08/04/2023 and needs to be maintained until full C of O
Miscellaneous Correction
Informational
09/08/2023
Erosion control is in place at the time of this inspection
Miscellaneous Correction
Corrective Action Required
10/26/2023
Erosion control has been removed and needs to be replaced or sod is required.
Plot Plan Inspection Passed 11/9/2023 11/09/2023
Occupancy Inspection - Codes Residential Failed 11/9/2023 11/9/2023 11/09/2023
Miscellaneous Correction
Corrective Action Required
11/09/2023
1804 occupancy driveway lamps need to be sealed at the top Exterior sump pump extension does not exceed 3 feet out from the foundation Seal top of a/c disconnect Seal top of electrical meter box Pay fees associated with this permit
Erosion Control Inspection Residential Passed 11/9/2023 11/09/2023
Miscellaneous Correction
Informational
10/26/2023
Erosion control is in place as of 08/04/2023 and needs to be maintained until full C of O
Miscellaneous Correction
Informational
10/26/2023
Erosion control is in place at the time of this inspection
Miscellaneous Correction
Resolved
11/09/2023
Erosion control has been removed and needs to be replaced or sod is required.
Occupancy Inspection - Codes Residential Full C of O 11/10/2023 11/10/2023
Miscellaneous Correction
Resolved
11/10/2023
1804 occupancy driveway lamps need to be sealed at the top Exterior sump pump extension does not exceed 3 feet out from the foundation Seal top of a/c disconnect Seal top of electrical meter box Pay fees associated with this permit
Documents & Images
Date Uploaded File Type Document Name
06/28/2023 RR #98 - Carbondale - Craftsman - Sheets
06/28/2023 98 RESERVE AT STONEY CREEK ROOF LAYOUT
06/28/2023 RR #98 - PERMIT APP
06/28/2023 I58885167_R01_B230098
06/28/2023 LOT 98 CON
07/03/2023 Permit Codes Residential Plan Review
07/03/2023 Approved Plans APPROVED PLANS
07/03/2023 Approved Plans APPROVED TRUSS LAYOUT
07/03/2023 Approved Plans APPROVED TRUSS PACKAGE
07/11/2023 LOT 98 FINAL 7-11-23
07/11/2023 Plot Plan approved plot plan
07/11/2023 Permit Codes Residential Plan Review
07/12/2023 Permit DS Building Permit
07/12/2023 Receipt Receipt for transaction:2023-005375
07/17/2023 Letter INSPECTION SUMMARY
07/17/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
08/04/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/25/2023 Letter INSPECTION SUMMARY
09/25/2023 Letter INSPECTION SUMMARY
10/26/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Receipt Receipt for transaction:2023-008401
11/10/2023 Letter Codes Final Certificate of Occupancy
11/10/2023 Letter Field Certificate of Occupancy
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home