Summary
PRRES20231984
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
05/03/2023
05/16/2023
11/01/2023
06/13/2024
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
Steve Froehlich, Address:406 NW Donovan Rd  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
steve@kc-customhomes.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,730.00 $3,730.00 Paid 05/16/2023
Water Meter Fee $550.50 $550.50 Paid 05/16/2023
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 05/16/2023
Right of Way Permit Fee $85.00 $85.00 Paid 05/16/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/16/2023
Valuation Fee New Single Family $1,590.91 $1,590.91 Paid 05/16/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/28/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 05/22/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/8/2023 6/8/2023 06/08/2023
Misc
Informational
06/08/2023
Footing approved by David Ainsworth on 5/22/23
Sewer Service Inspection - R Passed 6/19/2023 (1:30) 6/19/2023 06/19/2023
Water Service Inspection - R Failed 6/19/2023 (1:30) 6/19/2023 06/19/2023
Misc
Informational
06/19/2023
PEX line ran about 30 feet out from foundation wall, but not hooked up to copper supply line. This is a partial water line pass only.
Underslab Plumbing Inspection - Residential Passed 6/21/2023 6/21/2023 06/21/2023
Piers/Caissons Inspection - Residential Passed 6/21/2023 06/21/2023
Misc
Resolved
06/21/2023
PEX line ran about 30 feet out from foundation wall, but not hooked up to copper supply line. This is a partial water line pass only.
Erosion Control Inspection Residential Failed 6/21/2023 6/21/2023 06/21/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/21/2023
6/21/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Water Service Inspection - R Passed 6/28/2023 (9:45) 6/28/2023 06/28/2023
Misc
Informational
06/28/2023
PEX line ran about 30 feet out from foundation wall, but not hooked up to copper supply line. This is a partial water line pass only.
Electrical Service Inspection Failed 9/18/2023 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
-Ufer ground loose inside main panel
Gas Service Inspection - Residential Failed 9/18/2023 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
-Insufficient pressure (only had 2lbs) to test system
All Rough Inspection - Residential Failed 9/18/2023 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
-Missing fire block at top plate next to I beam in garage, both ends -Missing nut at bottom plate left side of garage -Missing fire blocking at top plate to the left of entry door in garage -Address 2x10 at valley spliced together above un named Room that backs to garage -Address over-bored top plate in laundry, strapping -Address fire blocking at vaulted ceiling in kitchen south wall -Purlin bracing is cantilevered at stud support south side -Address insufficient stud pack at right side of door to kitchen -Fireplace not installed, gas line not attached -Address spliced king and jack studs at front door need to be continuous -Address un and or lack of support underneath each purlin -Address fire blocking at top of fireplace insufficient thickness -Address hole in fire blocking behind basement fridge area, top -Add multiple vertical supports at ceilings in bar area of basement -Missing outlet on west wall of basement -Address cut out top plate at unmarked room and at top plate in bathroom of bedroom number 5 (return air vent????)
Misc
Corrective Action Required
09/18/2023
-Address insufficient nails at bottom of exterior sheathing throughout
Electrical Service Inspection Passed 9/27/2023 9/27/2023 09/27/2023
Misc
Corrective Action Required
09/18/2023
-Ufer ground loose inside main panel
Gas Service Inspection - Residential Passed 9/27/2023 9/27/2023 09/27/2023
Misc
Resolved
09/27/2023
All Rough Inspection - Residential Failed 9/27/2023 9/27/2023 09/27/2023
Misc
Resolved
09/27/2023
Misc
Corrective Action Required
09/27/2023
-Insufficient nails at bottom of exterior sheathing throughout
All Rough Inspection - Residential Passed 9/29/2023 9/29/2023 09/29/2023
Misc
Resolved
09/29/2023
Erosion Control Inspection Residential Failed 11/8/2023 11/08/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/08/2023
6/21/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL AT PERIMETER OF LOT **IF NOT IN COMPLIANCE IN 2 BUSINESS DAYS, A STOP WORK ORDER WILL BE ISSUED
Erosion Control Inspection Residential Partial 11/13/2023 11/13/2023 11/13/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/13/2023
6/21/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/13/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL AT PERIMETER OF LOT **IF NOT IN COMPLIANCE IN 2 BUSINESS DAYS, A STOP WORK ORDER WILL BE ISSUED
Misc
Informational
11/13/2023
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 3/26/2024 3/26/2024 03/26/2024
Misc
Corrective Action Required
03/26/2024
-Address plot plan does not match what is built -obtain issued lawn irrigation permit -sod -splash blocks and sump pump discharge installed and to extend 36” from foundation -water meter to be 14”-18” from top of meter to ring of lid (will check at time of sod) -uncover covered manhole (see plot plan) -missing hardware at rear deck slider -set screw at water anti syphon device sheered off -complete electrical at front entry and basement bar -label breaker in main panel not labeled -address handrail continuity at bottom of stairs to basement
Occupancy Inspection - Codes Residential Ready for Temp CO 3/28/2024 3/28/2024 03/28/2024
Misc
Corrective Action Required
03/26/2024
-Address plot plan does not match what is built -obtain issued lawn irrigation permit -sod -splash blocks and sump pump discharge installed and to extend 36” from foundation -water meter to be 14”-18” from top of meter to ring of lid (will check at time of sod) -uncover covered manhole (see plot plan)
Sidewalk Inspection Passed 10/2/2023 10/2/2023 05/22/2024
Misc
Informational
10/02/2023
10-2-23 DP. SW was formed, aggregate compacted, forms in compliance. But conditions can change. Approved to pour. 5-22-24 RH. Sidewalk meets ADA specification.
Driveway Inspection Passed 10/9/2023 10/9/2023 05/22/2024
Misc
Informational
10/02/2023
10-2-23 DP. DW is formed, aggregate compacted. Told to keep ADA complaince across the approach, approved to pour. 5-22-24 RH. Driveway meets ADA specification.
Occupancy Inspection - Codes Residential Failed 5/22/2024 05/22/2024
Misc
Resolved
05/22/2024
-splash blocks and sump pump discharge installed and to extend 36” from foundation -water meter to be 14”-18” from top of meter to ring of lid (will check at time of sod) -uncover covered manhole (see plot plan)
Misc
Corrective Action Required
03/29/2024
3/28/24:-splash blocks and sump pump discharge installed and to extend 36” from foundation -water meter to be 14”-18” from top of meter to ring of lid (will check at time of sod) -uncover covered manhole (see plot plan) Mitchell Schwarz 03/29/2024 8:19 AM- MARK HARDING 05/21/2024 10:14 AM Met with Owner and Builder on site to discuss issue of raising grade and slope at rear of lot. Manhole needs raised ( developer has been contacted) Check water meter for correcct height. Builder to address sink hole front of yard and low spot at the rear corner of the house, east side.
Occupancy Inspection - Codes Residential Ready for Temp CO 5/22/2024 05/22/2024
Misc
Corrective Action Required
05/22/2024
3/28/24:-splash blocks and sump pump discharge installed and to extend 36” from foundation -water meter to be 14”-18” from top of meter to ring of lid (will check at time of sod) -uncover covered manhole (see plot plan) Mitchell Schwarz 03/29/2024 8:19 AM- MARK HARDING 05/21/2024 10:14 AM Met with Owner and Builder on site to discuss issue of raising grade and slope at rear of lot. Manhole needs raised ( developer has been contacted) Check water meter for correcct height. Builder to address sink hole front of yard and low spot at the rear corner of the house, east side.
Informational
05/22/2024
approved for TCO extension 4-28 fee if not approved by 5-28 additional fee will be required.
Plot Plan Inspection Passed 6/13/2024 06/13/2024
Erosion Control Inspection Residential Passed 06/13/2024
Misc
Resolved
06/13/2024
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Full C of O 6/13/2024 6/13/2024 06/13/2024
Documents & Images
Date Uploaded File Type Document Name
05/03/2023 Permit Application
05/03/2023 Excise Tax Form Filled Out
05/05/2023 Plot Plan APPROVED PLOT PLAN
05/05/2023 Permit Codes Residential Plan Review
05/09/2023 Approved Plans APPROVED PLANS
05/09/2023 Permit Codes Residential Plan Review
05/16/2023 Permit DS Building Permit
05/16/2023 Receipt Receipt for transaction:2023-003357
06/07/2023 Wilmoth 2062 NW Obrien Rd LSMO Foundation Subgrade and Footing Inspection Report 5-22-23
06/08/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/28/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/25/2023 2023_09_21_2062 NW Obrien Rd_LSMO_City Rough-in Comments Response_Sealed
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/29/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
11/13/2023 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/28/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/28/2024 Receipt Receipt for transaction:2024-001987
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/22/2024 Receipt Receipt for transaction:2024-003827
06/11/2024 Plot Plan APPROVED AS GRADED PLOT PLAN
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter Field Certificate of Occupancy
06/13/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home