Permit Application Status

PRRES20231599


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231599
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
04/12/2023
07/10/2023
01/02/2024
06/10/2024
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
JP Roberts, Address:4335 McGee St  
JPROBERTS23@HOTMAIL.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 07/10/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/10/2023
Valuation Fee New Single Family $2,346.07 $2,346.07 Paid 07/10/2023
Water Tap Fee $3,760.00 $3,760.00 Paid 07/10/2023
Water Meter Fee $680.46 $680.46 Paid 07/10/2023
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/10/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 04/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/20/2023 07/20/2023
Misc
Informational
07/20/2023
- 2 UFER locations, garage wall and North wall 10' back from front.
Underslab Plumbing Inspection - Residential Passed 8/8/2023 8/8/2023 08/08/2023
Erosion Control Inspection Residential Partial 10/11/2023 10/11/2023
Misc
Corrective Action Required
10/11/2023
In place at this time
All Rough Inspection - Residential Failed 10/11/2023 10/11/2023 10/11/2023
Misc
Corrective Action Required
10/11/2023
Portel frame only outside ok -inside provide straps.
Sewer Service Inspection - R Passed 10/19/2023 (1:00) 10/19/2023 10/19/2023
Water Service Inspection - R Passed 10/20/2023 (1:00) 10/20/2023 10/20/2023
Misc
Informational
10/20/2023
10-20-23 Dustin A, WM is set, And heights and depths are are in compliance . Water is turned on. Passed
All Rough Inspection - Residential Failed 11/14/2023 11/14/2023 11/14/2023
Misc
Resolved
11/14/2023
Portel frame only outside ok -inside provide straps.
Misc
Corrective Action Required
11/14/2023
- Provide strap extortion corner kitchen at cut studs - Strap top plate master bedroom at entry - Provide Boca plates masters bath at vanities - Solid block exterior wall master bedroom between window and entry - Support gas line first floor powder room - Anchor bolts to be in middle third of plate, garage - Provide scuppers for roof deck - Complete both fireplaces - Purlin struts to be 4’ on center
Electrical Service Inspection Passed 11/14/2023 11/14/2023 11/14/2023
Gas Service Inspection - Residential Failed 11/14/2023 11/14/2023 11/14/2023
Misc
Corrective Action Required
11/14/2023
Not ready
All Rough Inspection - Residential Failed 11/20/2023 11/20/2023 11/20/2023
Misc
Corrective Action Required
11/14/2023
- Purlin struts to be 4’ on center
Gas Service Inspection - Residential Passed 11/20/2023 11/20/2023 11/20/2023
Misc
Resolved
11/20/2023
Not ready
All Rough Inspection - Residential Passed 11/22/2023 11/22/2023 11/22/2023
Misc
Resolved
11/22/2023
- Purlin struts to be 4’ on center
Sidewalk Inspection Partial 03/19/2024
Misc
Informational
03/19/2024
3-19-24 Dustin A, Sw is formed and aggregate is compacted. Instructed JP that he needs to pour missing panel across street as well. Approved to pour,
Sidewalk Inspection Failed 3/26/2024 3/26/2024 03/26/2024
Misc
Informational
03/19/2024
3-19-24 Dustin A, Sw is formed and aggregate is compacted. Instructed JP that he needs to pour missing panel across street as well. Approved to pour, 3-26-24 Dustin A, Sw is poured and slopes are in compliance. Did not apply white cure and panel that was cut out for tap hole still needs to be poured
Sidewalk Inspection Partial 03/27/2024
Misc
Informational
03/26/2024
3-19-24 Dustin A, Sw is formed and aggregate is compacted. Instructed JP that he needs to pour missing panel across street as well. Approved to pour, 3-26-24 Dustin A, Sw is poured and slopes are in compliance. Did not apply white cure and panel that was cut out for tap hole still needs to be poured 3-27-24 Dustin A, Cure meets city specs, cannot pass until forms pulled and section replaced across street
Sidewalk Inspection Passed 4/10/2024 4/10/2024 04/10/2024
Misc
Informational
03/27/2024
3-19-24 Dustin A, Sw is formed and aggregate is compacted. Instructed JP that he needs to pour missing panel across street as well. Approved to pour, 3-26-24 Dustin A, Sw is poured and slopes are in compliance. Did not apply white cure and panel that was cut out for tap hole still needs to be poured 3-27-24 Dustin A, Cure meets city specs, cannot pass until forms pulled and section replaced across street 4-10-24 DP. Forms have been removed, section where water tab was made has been repoured. It is at 2.3% cross slope but matches up with existing. Passed.
Occupancy Inspection - Codes Residential Failed 4/10/2024 4/10/2024 04/10/2024
Misc
Corrective Action Required
04/10/2024
- NEC 210.52.5 Outlet on island on overhang not allowed, overhang shall be under 6” or needs to be surface mounted. - house numbers to be illuminated and contrasting in color - Complete spindles at garage stairs - Fb penetrations at garage outlets - Garage door must be self closing and latch - Attach SEC within 12” of panel - Final grading and sod - Provide splash pads 36” away from foundation - Extend sump discharge 36” away from foundation - Do not cover man hole at front of house
Plot Plan Inspection Passed 4/10/2024 04/10/2024
Erosion Control Inspection Residential Partial 4/10/2024 04/10/2024
Misc
Corrective Action Required
10/11/2023
In place at this time
Occupancy Inspection - Codes Residential Ready for Temp CO 4/11/2024 4/11/2024 04/11/2024
Misc
Corrective Action Required
04/10/2024
- Land sewer trace wire to grade - Final grading and sod - Provide splash pads 36” away from foundation - Extend sump discharge 36” away from foundation - Do not cover man hole at front of house
Erosion Control Inspection Residential Passed 6/6/2024 06/06/2024
Misc
Resolved
06/06/2024
In place at this time
Occupancy Inspection - Codes Residential Failed 6/6/2024 6/6/2024 06/06/2024
Misc
Corrective Action Required
04/11/2024
- Land sewer trace wire to grade - Side walk inspection pending
Occupancy Inspection - Codes Residential Full C of O 6/10/2024 06/10/2024
Misc
Resolved
06/10/2024
- Land sewer trace wire to grade - Side walk inspection pending
Documents & Images
Date Uploaded File Type Document Name
04/12/2023 1051 SW Corinthian Pl_ Excise Tax Application
04/12/2023 1051 SW Corinthian Pl_ Permit Application
04/12/2023 COMPLETE SET 21-007-04 ROBERTS-CASTLE - MO
04/12/2023 LOT 133 FIT
06/30/2023 LOT 133 FINAL
07/06/2023 Permit Codes Residential Plan Review
07/06/2023 Approved Plans APPROVED PLANS
07/07/2023 LOT 133 CITY NEW
07/07/2023 Permit Codes Residential Plan Review
07/10/2023 Permit DS Building Permit
07/10/2023 Receipt Receipt for transaction:2023-005312
07/20/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/19/2023 Letter INSPECTION SUMMARY
10/20/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/22/2024 3RD Party Insp Report Final_2024_03_19_DPier_LSMO_Pat Cochran Concrete
03/26/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/27/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Plot Plan APPROVED PLOT PLAN
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/11/2024 Receipt Receipt for transaction:2024-002328
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter Field Certificate of Occupancy
06/10/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: