Summary
PRRES20231588
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
04/12/2023
04/18/2023
01/19/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 434-5074 Ext:321  
JASONH@CLOVERANDHIVE.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 04/18/2023
Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/18/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 04/18/2023
Water Meter Fee $550.50 $550.50 Paid 04/18/2023
Valuation Fee New Single Family $1,553.26 $1,553.26 Paid 04/18/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/24/2023 04/24/2023
Underslab Plumbing Inspection - Residential Passed 4/28/2023 4/28/2023 04/28/2023
Sewer Service Inspection - R Passed 5/2/2023 (10:45) 5/2/2023 05/02/2023
Water Service Inspection - R Passed 5/3/2023 (9:00) 5/3/2023 05/03/2023
Erosion Control Inspection Residential Partial 5/31/2023 05/31/2023
Miscellaneous Correction
Informational
05/31/2023
Erosion control in place at all rough
Electrical Service Inspection Passed 5/31/2023 05/31/2023
Gas Service Inspection - Residential Passed 5/31/2023 5/31/2023 05/31/2023
All Rough Inspection - Residential Failed 5/31/2023 5/31/2023 05/31/2023
Miscellaneous Correction
Corrective Action Required
05/31/2023
- Garage chase at the ceiling needs fire blocking - Joist hanger in kitchen is not nailed off correctly - Address (2) 2x10 ceiling joist by pantry - Joist hanger in dining room is missing a nail - Joist hanger in entry is missing nails - Fire block at fir down horizontal in garage entry bathroom is missing - Fire blocking in top plate at stairwell is missing - Address top plate breaks with flat studs and metal straps - Fire block a/c chase at the ceiling in the upper floor hallway - Stud pack in stairwell needs to be addressed - Bottom anchors in basement are missing washers and nuts - I beam pockets in basement need to be fire blocked - I beams sitting less than 3 inch on concrete in basement need to be addressed - 2x12 ceiling joist by basement window needs to be bottom nailed through the top plate - A/c blower whip needs to be attached to the 2x12
All Rough Inspection - Residential Passed 6/1/2023 6/1/2023 06/01/2023
Miscellaneous Correction
Resolved
06/01/2023
- Stud pack in stairwell needs to be addressed - Bottom anchors in basement are missing washers and nuts - I beam pockets in basement need to be fire blocked - I beams sitting less than 3 inch on concrete in basement need to be addressed - 2x12 ceiling joist by basement window needs to be bottom nailed through the top plate - A/c blower whip needs to be attached to the 2x12
Driveway Inspection Passed 7/17/2023 07/20/2023
Misc
Informational
07/17/2023
7-17-23 BR Driveway is framed and ready for concrete 7-20-23 BR Driveway is concrete to LS specification
Sidewalk Inspection Passed 7/17/2023 07/20/2023
Misc
Informational
07/17/2023
7-17-23 BR Sidewalk is framed and ready for concrete 7-20-23 BR Sidewalkis concrete to LS specification
Miscellaneous Inspection Passed 12/8/2023 12/08/2023
Miscellaneous Correction
Informational
12/08/2023
Builder submitted a permit extension form. This is the first extension request for this address. Permit extension is approved 12/08/23 KBEARD
Occupancy Inspection - Codes Residential Failed 12/19/2023 12/19/2023 12/19/2023
Miscellaneous Correction
Corrective Action Required
12/19/2023
2121 SW Rutherford. Occupancy -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -Sod to siding in the front yard needs to have a clearance of 6 inches in height
Erosion Control Inspection Residential Passed 12/19/2023 12/19/2023
Miscellaneous Correction
Informational
05/31/2023
Erosion control in place at all rough
Occupancy Inspection - Codes Residential Failed 1/5/2024 1/5/2024 01/05/2024
Miscellaneous Correction
Resolved
01/05/2024
2121 SW Rutherford. Occupancy -Interior stair handrail has a graspable clearance of 5/8 of an inch. Code clearance is 1 1/2 inch -Hot water tank cold water side is out of its support bracket at ceiling joist -Sod to siding in the front yard needs to have a clearance of 6 inches in height
Miscellaneous Correction
Corrective Action Required
01/05/2024
2121 SW Rutherford. Occupancy Guard rail is needed on the front porch east side Garage to house self closing door hinge is not fully functioning to close all the way and latch Attic access hatch in garage is not sealed Lower window in stairwell needs to be laminated glass First flight of stairs (nosing) to the platform landing in the basement does not have 36 inches of clearance to the wall Seal top of electrical meter Seal gas meter to siding gap
Plot Plan Inspection Passed 1/5/2024 01/05/2024
Occupancy Inspection - Codes Residential Failed 1/10/2024 1/10/2024 01/10/2024
Miscellaneous Correction
Resolved
01/10/2024
2121 SW Rutherford. Occupancy Guard rail is needed on the front porch east side Garage to house self closing door hinge is not fully functioning to close all the way and latch Attic access hatch in garage is not sealed Lower window in stairwell needs to be laminated glass First flight of stairs (nosing) to the platform landing in the basement does not have 36 inches of clearance to the wall Seal top of electrical meter Seal gas meter to siding gap
Miscellaneous Correction
Corrective Action Required
01/10/2024
2121 SW Rutherford. Occupancy (2) Guard rail is needed on the front porch east side Garage to house self closing door hinge is not fully functioning to close all the way and latch Attic access hatch in garage is not sealed Lower window in stairwell needs to be laminated glass First flight of stairs (nosing) to the platform landing in the basement does not have 36 inches of clearance to the wall Seal top of electrical meter Seal gas meter to siding gap Doors are locked. No access provided 01/10/23 KBEARD
Occupancy Inspection - Codes Residential Full C of O 1/19/2024 1/19/2024 01/19/2024
Miscellaneous Correction
Resolved
01/19/2024
2121 SW Rutherford. Occupancy (2) Guard rail is needed on the front porch east side Garage to house self closing door hinge is not fully functioning to close all the way and latch Attic access hatch in garage is not sealed Lower window in stairwell needs to be laminated glass First flight of stairs (nosing) to the platform landing in the basement does not have 36 inches of clearance to the wall Seal top of electrical meter Seal gas meter to siding gap Doors are locked. No access provided 01/10/23 KBEARD
Documents & Images
Date Uploaded File Type Document Name
04/12/2023 OS #71 - 230403
04/12/2023 71 osage roof layout
04/12/2023 P230132 - Clover and Hive - Osage Lot 71 - Sealed Drawings
04/12/2023 LOT 71 FINAL
04/12/2023 OS #71 - PERMIT APP
04/12/2023 Approved Plans APPROVED PLANS
04/12/2023 Approved Plans APPROVED TRUSS LAYOUT
04/12/2023 Approved Plans APPROVED TRUSS PACKAGE
04/12/2023 Plot Plan approved plot plan
04/13/2023 Permit Codes Residential Plan Review
04/13/2023 Permit Codes Residential Plan Review
04/18/2023 Permit DS Building Permit
04/18/2023 Permit DS Building Permit
04/18/2023 Receipt Receipt for transaction:2023-002154
04/21/2023 ML Crose 2121 SW Rutherford Dr LSMO Wall Inspection Report 4-20-23
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 71 osage pantry header clarification
07/17/2023 Letter INSPECTION SUMMARY
07/17/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
12/07/2023 Letter Codes 140 Day Letter
12/07/2023 OS #71 - Permit Extension App
12/08/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/10/2024 Letter INSPECTION SUMMARY
01/10/2024 Letter INSPECTION SUMMARY
01/19/2024 Letter Codes Final Certificate of Occupancy
01/19/2024 Letter Codes Final Certificate of Occupancy
01/19/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home