Summary
PRRES20226269
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ENGINEERED FLOOR SYSTEM. STOP WORK ORDER generated on 06/11/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/12/2024 12:00 AM by username 'Robb Popp'.
12/29/2022
01/27/2023
07/04/2023
06/20/2024
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
Rick holbrook , Address:528 NW. AA Highway  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ANTHONY@PFEIFERHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,730.00 $3,730.00 Paid 01/27/2023
Water Meter Fee $550.50 $550.50 Paid 01/27/2023
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 01/27/2023
Right of Way Permit Fee $85.00 $85.00 Paid 01/27/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/27/2023
Valuation Fee New Single Family $1,704.10 $1,704.10 Paid 01/27/2023
Additional Permit Fee $200.00 $200.00 Paid 05/16/2024
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 2/7/2023 (2:30) 2/7/2023 02/07/2023
Misc
Corrective Action Required
02/07/2023
Provide engineered documentation for spread footing on west side (24" wide w 3 bars and cross bar 4' oc)
Sewer Service Inspection - R Passed 3/1/2023 3/1/2023 03/01/2023
Water Service Inspection - R Partial 3/2/2023 (9:00) 3/2/2023 03/02/2023
Misc
Informational
03/02/2023
Pex ran from foundation
Water Service Inspection - R Passed 3/2/2023 (1:00) 3/2/2023 03/02/2023
Misc
Resolved
03/02/2023
Pex ran from foundation
Erosion Control Inspection Residential Failed 03/02/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/02/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Failed 3/15/2023 03/15/2023
Misc
Corrective Action Required
03/15/2023
test report for inspector
Misc
Corrective Action Required
03/15/2023
-Address not posted -Missing erosion control -Excessive construction debris/trash behind house
Underslab Plumbing Inspection - Residential Not Ready 4/6/2023 4/6/2023 04/06/2023
Misc
Resolved
04/06/2023
test report for inspector
Misc
Resolved
04/06/2023
-Address not posted -Missing erosion control -Excessive construction debris/trash behind house
Misc
Corrective Action Required
04/06/2023
-Complete interior drain tile
Underslab Plumbing Inspection - Residential Passed 4/28/2023 4/28/2023 04/28/2023
Misc
Resolved
04/28/2023
All Rough Inspection - Residential Failed 9/8/2023 9/8/2023 09/08/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed
Electrical Service Inspection Failed 9/8/2023 9/8/2023 09/08/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed
Gas Service Inspection - Residential Failed 9/8/2023 9/8/2023 09/08/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed
All Rough Inspection - Residential Failed 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed REQUIRE COMPLETE SET OF STAMPED PLANS----INSPECTION NOT PERFORMED
Electrical Service Inspection Failed 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed REQUIRE COMPLETE SET OF STAMPED PLANS----INSPECTION NOT PERFORMED
Gas Service Inspection - Residential Failed 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
09/08/2023
-plans not on site, inspection not performed REQUIRE COMPLETE SET OF STAMPED PLANS----INSPECTION NOT PERFORMED
Electrical Service Inspection Passed 9/14/2023 9/14/2023 09/14/2023
Misc
Corrective Action Required
09/11/2023
-plans not on site, inspection not performed REQUIRE COMPLETE SET OF STAMPED PLANS----INSPECTION NOT PERFORMED
Gas Service Inspection - Residential Passed 9/14/2023 9/14/2023 09/14/2023
Misc
Informational
09/14/2023
CITY STAMPED plans still not on site
All Rough Inspection - Residential Failed 9/14/2023 9/14/2023 09/14/2023
Misc
Corrective Action Required
09/11/2023
-plans not on site, inspection not performed REQUIRE COMPLETE SET OF STAMPED PLANS----INSPECTION NOT PERFORMED
Misc
Corrective Action Required
09/14/2023
CITY STAMPED PLANS NOT ON SITE
All Rough Inspection - Residential Failed 9/15/2023 9/15/2023 09/15/2023
Misc
Resolved
09/15/2023
Misc
Resolved
09/15/2023
Misc
Corrective Action Required
09/15/2023
-Missing tie down nut at base plate near large garage door -Missing blocking at load bearing wall in garage -Structural strapping required at all over bored top plates in garage -Missing hangers at ceiling joists in garage -Missing fire blocking in garage above large garage door -Bocca plate at bottom of radon pipe in garage -DWV not secure in center at garage -No portal framing inspection done -Blocking at the panel splice needs to be in the center at garage to the right of the large garage door -Missing joist hangers. In garage -Strap top plates in garage where over bored -DWV above laundry insufficient sloped -Nail all exterior corners per code, insufficient nails -Strapping needed at top plate spanning dinning room and pantry -Missing exhaust fan tube at 1/2 bath off of garage and master and throughout -Missing stud at curved part of stairs at LVL -Missing stud under LVL in kitchen at south wall -Correct short joist in office -Address insufficient slope DWV above walk in closet -Missing strapping at top plate of master bathroom -Secure pex at master shower -Missing strapping at top plate at master WC -Have LVL in dining room landing on cantilevered LVL addressed by engineer -Address Over-notched rafter at same area -Furnace exhaust flue has improper clearance and exceeds maximum offset for a 5inch flue -Missing and incorrect fire blocking at top of chase near kitchen -Incorrect fire blocking material at chase near stairs -Provide light switch at top and bottom of stairs -Provide 2 King studs at front door per plans -Address purlin bracing landing on non load bearing wall near fireplace -Install security blocking at exterior doors per Chapter 7 of the City code -Missing fire blocking under garage stairs -Install fire blocking in ceilings of electrical room -Missing fire blocking at top of west wall in basement and through out -Address multiple issues with anchor bolts in basement, missing--not in center 1/3-- no nuts... -Address insufficient 2x4's at exterior corners in basement -Secure Main water line -Clarify type of screws used at ledger plate at deck -Have engineer address post not landing on footing at deck -Missing 1/2 inch through bolts at post and beam connections at deck -Have engineer address over notching at corner post on deck -Address insufficient nails on exterior siding see plans
All Rough Inspection - Residential Failed 10/30/2023 10/30/2023 10/30/2023
Misc
Partial Correction
10/30/2023
-Nail all exterior corners per code, insufficient nails -Missing fire blocking at top of chase near kitchen -Install security blocking at exterior doors per Chapter 7 of the City code -Missing fire blocking under garage stairs -Install fire blocking in ceilings of electrical room -Address insufficient 2x4's at exterior corners in basement
All Rough Inspection - Residential Passed 11/2/2023 11/2/2023 11/02/2023
Misc
Resolved
11/02/2023
-Nail all exterior corners per code, insufficient nails -Missing fire blocking at top of chase near kitchen -Install security blocking at exterior doors per Chapter 7 of the City code -Missing fire blocking under garage stairs -Install fire blocking in ceilings of electrical room -Address insufficient 2x4's at exterior corners in basement
Erosion Control Inspection Residential Failed 11/02/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
11/02/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/02/2023
11/2/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at perimeter and clean silt and gravel from street immediatley
Driveway Inspection Partial 11/10/2023 11/10/2023 11/10/2023
Misc
Informational
11/10/2023
11-10-23 DP. Crew had DW formed, aggregate compacted. approved to pour.
Driveway Inspection Passed 11/17/2023 11/17/2023 11/17/2023
Misc
Informational
11/10/2023
11-10-23 DP. Crew had DW formed, aggregate compacted. approved to pour. 11-17-23 Dustin A, DW is poured and frames pulled. Passed
Occupancy Inspection - Codes Residential Failed 5/30/2024 5/30/2024 05/30/2024
Misc
Corrective Action Required
05/30/2024
-No drain hose loop under sink at dishwasher -Loose joist hangers at deck -Missing 1/2 inch through bolts at post to beam connections at deck -Secure AC whip within 1 ft of disconnect -Missing light fixtures at rear of house -Missing sod and splash blocks -Upload 3rd party inspection for piers and footings
Footing Inspection - Residential Failed - Stop Work 06/11/2024
Misc
Corrective Action Required
02/07/2023
Provide engineered documentation for spread footing on west side (24" wide w 3 bars and cross bar 4' oc) ***6/11/24 -FOOTING WAS FAILED ON 2/723 AND IS STILL MISSING ENGINEERED REPORT. STOP WORK IS ISSUED UNTIL RESOLVED
Erosion Control Inspection Residential Failed 06/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/11/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL OR VEGETATION. STOP WORK ISSUED ON FAILED FOOTING
Footing Inspection - Residential Passed 06/12/2024
Misc
Resolved
06/12/2024
Provide engineered documentation for spread footing on west side (24" wide w 3 bars and cross bar 4' oc) ***6/11/24 -FOOTING WAS FAILED ON 2/723 AND IS STILL MISSING ENGINEERED REPORT. STOP WORK IS ISSUED UNTIL RESOLVED
Occupancy Inspection - Codes Residential Failed 6/13/2024 6/13/2024 06/13/2024
Misc
Partial Correction
06/13/2024
-Missing 1/2 inch through bolts at post to beam connections at deck -Missing one splash block at rear of house
Erosion Control Inspection Residential Passed 06/20/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
06/20/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL OR VEGETATION. STOP WORK ISSUED ON FAILED FOOTING
Plot Plan Inspection Passed 06/20/2024
Piers/Caissons Inspection - Residential Passed 06/20/2024
Occupancy Inspection - Codes Residential Full C of O 6/20/2024 6/20/2024 06/20/2024
Misc
Resolved
06/20/2024
-Missing 1/2 inch through bolts at post to beam connections at deck -Missing one splash block at rear of house
Documents & Images
Date Uploaded File Type Document Name
12/29/2022 spec permit 184 WR
01/05/2023 Approved Plans APPROVED PLANS
01/05/2023 Approved Plans APPROVED JOIST DRAWINGS
01/05/2023 Permit Codes Residential Plan Review
01/24/2023 Plot Plan APPROVED PLOT PLAN
01/24/2023 Permit Codes Residential Plan Review
01/27/2023 Permit DS Building Permit
01/27/2023 Receipt Receipt for transaction: 2023-000536
02/07/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
04/06/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
10/30/2023 Letter INSPECTION SUMMARY
11/01/2023 SKMBT_C284e23103122150
11/02/2023 Letter INSPECTION SUMMARY
11/02/2023 Letter INSPECTION SUMMARY
11/17/2023 Letter INSPECTION SUMMARY
04/05/2024 Letter Codes 140 Day Letter
05/15/2024 Letter Codes 180 Day Letter
05/16/2024 Receipt Receipt for transaction: 2024-003540
05/30/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter Stop Work Order
06/11/2024 Letter INSPECTION SUMMARY
06/12/2024 Killarney as graded plot plan
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/14/2024 Engineer Report/Study FOOTING ENGINEER REPORT
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter Codes Final Certificate of Occupancy
06/20/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home