Permit Application Status

PRRES20224901


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224901
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
10/03/2022
11/07/2022
04/02/2023
07/14/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 11/07/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 11/07/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 11/07/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/07/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 11/07/2022
9110078-Valuation Fee New Single Family $1,381.46 $1,381.46 Paid 11/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
No address posted inspection denied
Footing Inspection - Residential Passed 12/1/2022 12/01/2022
Underslab Plumbing Inspection - Residential Passed 12/1/2022 12/1/2022 12/01/2022
Misc
Resolved
12/01/2022
No address posted inspection denied
Sewer Service Inspection - R Passed 12/2/2022 (1:00) 12/2/2022 12/02/2022
Water Service Inspection - R Partial 12/2/2022 (1:00) 12/2/2022 12/02/2022
Misc
Corrective Action Required
12/02/2022
partial water pex ran roughly 15' from foundation
Water Service Inspection - R Passed 12/5/2022 (9:15) 12/5/2022 12/05/2022
Misc
Resolved
12/05/2022
Electrical Service Inspection Passed 3/14/2023 3/14/2023 03/14/2023
All Rough Inspection - Residential Failed 3/14/2023 3/14/2023 03/14/2023
Misc
Corrective Action Required
03/14/2023
-anchor bolts throughout to be in the middle 1/3 of sill plate -nail exterior wall corners together to code and plans -tie exter wall corner in pantry and garage together -missing nail in hanger above kitchen/garage entry -secure gas line at fire place within 12” of disconnect -missing nails in hanger above master -fire block entryway N wall to ceiling space -jack studs required for header at front door above window -top plate penetration at front door -anchor all steel columns in basement -fire block furr down ends in basement -fire block at D column into furr down and right of
Gas Service Inspection - Residential Passed 3/14/2023 3/14/2023 03/14/2023
Piers/Caissons Inspection - Residential Passed 03/14/2023
All Rough Inspection - Residential Failed 3/14/2023 3/14/2023 03/14/2023
Misc
Corrective Action Required
03/14/2023
PROVIDE CITY STAMPED PLANS ON SITE -anchor bolts throughout to be in the middle 1/3 of sill plate -nail exterior wall corners together to code and plans -tie exter wall corner in pantry and garage together -missing nail in hanger above kitchen/garage entry -secure gas line at fire place within 12” of disconnect -missing nails in hanger above master -fire block entryway N wall to ceiling space -jack studs required for header at front door above window -top plate penetration at front door -anchor all steel columns in basement -fire block furr down ends in basement -fire block at D column into furr down and right of
All Rough Inspection - Residential Failed 4/7/2023 4/7/2023 04/07/2023
Misc
Corrective Action Required
03/14/2023
No inspection performed PROVIDE CITY STAMPED PLANS ON SITE -anchor bolts throughout to be in the middle 1/3 of sill plate -nail exterior wall corners together to code and plans -tie exter wall corner in pantry and garage together -missing nail in hanger above kitchen/garage entry -secure gas line at fire place within 12” of disconnect -missing nails in hanger above master -fire block entryway N wall to ceiling space -jack studs required for header at front door above window -top plate penetration at front door -anchor all steel columns in basement -fire block furr down ends in basement -fire block at D column into furr down and right of
All Rough Inspection - Residential Failed 4/10/2023 4/10/2023 04/10/2023
Misc
Partial Correction
04/10/2023
-address top of column south side as you go down the stairs to basement -fire block entryway N wall to ceiling space
All Rough Inspection - Residential Passed 4/12/2023 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
-address top of column south side as you go down the stairs to basement -fire block entryway N wall to ceiling space
Driveway Inspection Partial 5/2/2023 5/2/2023 05/02/2023
Misc
Informational
05/02/2023
5-2-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 05/02/2023
Misc
Informational
05/02/2023
5-2-23 RH. Sidewalk is formed up on the left side of the driveway and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 5/3/2023 05/03/2023
Misc
Informational
05/02/2023
5-2-23 RH. Sidewalk is formed up on the left side of the driveway and aggregate is placed and compacted. Approved to pour. 5-3-23 RH. Rest of sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Failed 5/9/2023 5/9/2023 05/10/2023
Misc
Informational
05/02/2023
5-2-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. A panel had prints on it and needs replaced.
Sidewalk Inspection Failed 5/9/2023 5/9/2023 05/10/2023
Misc
Informational
05/03/2023
5-2-23 RH. Sidewalk is formed up on the left side of the driveway and aggregate is placed and compacted. Approved to pour. 5-3-23 RH. Rest of sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. Prints were found on somesidewalk panels and will need replaced.
Driveway Inspection Passed 6/8/2023 6/8/2023 06/12/2023
Misc
Informational
05/10/2023
5-2-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. A panel had prints on it and needs replaced. 6-8-23 BR Driveway panel is frame and compacted ready for concrete 6-12-23 BR Driveway panel is concreted and meet LS specification
Sidewalk Inspection Passed 6/8/2023 6/8/2023 06/12/2023
Misc
Informational
05/10/2023
5-2-23 RH. Sidewalk is formed up on the left side of the driveway and aggregate is placed and compacted. Approved to pour. 5-3-23 RH. Rest of sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. Prints were found on somesidewalk panels and will need replaced. 6-8-23 BR Frame is installed and compacted ready for concrete on panels that needed to replace 6-12-23 BR Sidewalk is concreted to the LS specification
Occupancy Inspection - Codes Residential Failed 7/12/2023 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
Address pending driveway and sidewalk inspection -sod -splash block and sump pump discharge to extend 36” from foundation -Lock out for oven breaker -complete water heater wiring -address deck post to beam connections
Driveway Inspection Passed 07/13/2023
Misc
Informational
06/08/2023
5-2-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. A panel had prints on it and needs replaced. 6-8-23 BR Driveway panel is frame and compacted ready for concrete
Sidewalk Inspection Passed 07/13/2023
Misc
Informational
06/08/2023
5-2-23 RH. Sidewalk is formed up on the left side of the driveway and aggregate is placed and compacted. Approved to pour. 5-3-23 RH. Rest of sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 5-10-23 RH. Prints were found on somesidewalk panels and will need replaced. 6-8-23 BR Frame is installed and compacted ready for concrete on panels that needed to replace
Plot Plan Inspection Passed 07/13/2023
Occupancy Inspection - Codes Residential Failed 7/13/2023 7/13/2023 07/13/2023
Misc
Corrective Action Required
07/12/2023
-sod -splash block and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 07/14/2023
Occupancy Inspection - Codes Residential Full C of O 7/14/2023 7/14/2023 07/14/2023
Misc
Resolved
07/14/2023
-sod -splash block and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
10/03/2022 2602 SW Tracker Ln City Application
10/04/2022 Permit Codes Residential Plan Review
11/01/2022 Plot Plan APPROVED PLOT PLAN
11/01/2022 Approved Plans APPROVED PLANS
11/01/2022 Permit Codes Residential Plan Review
11/07/2022 Permit DS Building Permit
11/07/2022 Receipt Receipt for transaction:2022-008741
11/22/2022 Wilmoth 2602 SW Tracker LN LSMO Hook Farms Lot 126 3rd Party Subgrade and Footing Inspection Report 11-21-22
11/30/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/05/2022 Letter INSPECTION SUMMARY
12/07/2022 2602 Sw Tracker Ln ROW
12/16/2022 Final_2022_12_14_DPier_LSMO_Pat Cochran Concrete
03/14/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
04/07/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/12/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/12/2023 Letter INSPECTION SUMMARY
06/12/2023 Letter INSPECTION SUMMARY
06/12/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter Field Certificate of Occupancy
07/14/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: