Permit Application Status

PRRES20224595


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224595
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
09/16/2022
10/12/2022
03/25/2023
05/03/2024
Locations
Contacts
BE HOME LLC, Address:7618 S ARNETT RD, Phone:(816) 591-6013  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR STE 100  
Michael Powell, Address:1101 SW US 40 Highway, Phone:(816) 591-6013  
MIKE@BEHOMELLC.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
VELOCITY ELECTRIC AND AUTOMATION LLC, Address:1704 SW RED FOX CIR, Phone:(816) 215-1514  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 10/12/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/12/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 10/12/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 10/12/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 10/12/2022
9110078-Valuation Fee New Single Family $1,520.76 $1,520.76 Paid 10/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/27/2022 10/27/2022
Underslab Plumbing Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/27/2022
inspection denied -no address posted -no erosion control
Erosion Control Inspection Residential Failed 10/27/2022 10/27/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/27/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 11/1/2022 11/01/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Passed 11/1/2022 11/01/2022
Misc
Resolved
11/01/2022
inspection denied -no address posted -no erosion control
Sewer Service Inspection - R Passed 11/21/2022 (1:30) 11/21/2022 11/21/2022
Water Service Inspection - R Passed 12/7/2022 12/07/2022
Erosion Control Inspection Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
Clean trash and debris from lot Reestablish erosion control
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 4/5/2023 4/5/2023 04/05/2023
Misc
Corrective Action Required
04/05/2023
inspection denied fire block throughout
All Rough Inspection - Residential Failed 4/14/2023 4/14/2023 04/14/2023
Misc
Resolved
04/14/2023
inspection denied fire block throughout
Misc
Corrective Action Required
04/14/2023
-uncover cover pfh nailing for inspection -pfh at single car garage complete anchor bolts per design -missing multiple anchor bolts Along E wall in garage -address over notched exterior wall stud W bed 2 wall -seal top plate penetration NW dining room -if adding windows in master E wall this needs to be update and inspected -complete framing, plumbing and fire blocking for master tub and shower -fire block flex room E wall space to ceiling space -fire block entry to ceiling space (see left of powder room entry -missing but on anchor bolt E basement wall -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of the bolt. See E basement -fire blocking materials must comply with code section R302.11.1 of the 2018 IRC. -fire block W bed 4 wall into furr down -seal penetrations in RA panning above bed 4 -fire block N bed 4 wall to ceiling space. See entry -fire block all the all wall space to ceiling space along W wall -provide proper support for csst T Above basement rec room /beds hall -missing nails in hanger at stairs and mechanical -solid block at cantilever into garage -missing 2 steel columns in basement unfinished area
All Rough Inspection - Residential Failed 5/9/2023 5/9/2023 05/09/2023
Misc
Corrective Action Required
04/14/2023
-pfh at single car garage complete anchor bolts per design -address over notched exterior wall stud W bed 2 wall -fire block flex room E wall space to ceiling space -fire block entry to ceiling space (see left of powder room entry -fire blocking materials must comply with code section R302.11.1 of the 2018 IRC. -fire block W bed 4 wall into furr down -seal penetrations in RA panning above bed 4 -fire block all the wall space to ceiling space along W wall use approved materials -provide proper support for csst T Above basement rec room /beds hall
All Rough Inspection - Residential Passed 5/25/2023 5/25/2023 05/25/2023
Misc
Resolved
05/25/2023
-pfh at single car garage complete anchor bolts per design -address over notched exterior wall stud W bed 2 wall -fire block flex room E wall space to ceiling space -fire block entry to ceiling space (see left of powder room entry -fire blocking materials must comply with code section R302.11.1 of the 2018 IRC. -fire block W bed 4 wall into furr down -seal penetrations in RA panning above bed 4 -fire block all the wall space to ceiling space along W wall use approved materials -provide proper support for csst T Above basement rec room /beds hall
Gas Service Inspection - Residential Failed 6/2/2023 6/2/2023 06/02/2023
Misc
Corrective Action Required
06/02/2023
Can not verify gas bonding. Pressure okay
Electrical Service Inspection Passed 6/2/2023 6/2/2023 06/02/2023
Gas Service Inspection - Residential Passed 6/8/2023 6/8/2023 06/08/2023
Misc
Resolved
06/08/2023
Can not verify gas bonding. Pressure okay
Erosion Control Inspection Residential Failed 6/8/2023 6/8/2023 06/08/2023
Misc
Resolved
06/08/2023
Clean trash and debris from lot Reestablish erosion control
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/08/2023
Maintain over grown vegetation
Erosion Control Inspection Residential Failed 7/20/2023 7/20/2023 07/20/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/08/2023
Maintain over grown vegetation
Erosion Control Inspection Residential Failed 7/26/2023 07/26/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
07/20/2023
Maintain over grown vegetation
Driveway Inspection Passed 8/25/2023 8/25/2023 08/28/2023
Misc
Informational
08/25/2023
8-25-23 BR Driveway is formed up and aggregate is place and compacted. Ready for concrete. 8-28-23 BR Driveway is constructed to LS specification.
Sidewalk Inspection Passed 8/25/2023 8/25/2023 08/28/2023
Misc
Informational
08/25/2023
8-25-23 BR Sidewalk is formed up and aggregate is place and compacted. Ready for concrete. 8-28-23 BR Sidewalk is constructed to LS specification.
Erosion Control Inspection Residential Failed 2/6/2024 02/06/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/26/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
02/06/2024
Maintain over grown vegetation
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. No erosion control installed
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 4/18/2024 4/18/2024 04/18/2024
Misc
Corrective Action Required
04/18/2024
-Erosion control not in place
Piers/Caissons Inspection - Residential Passed 4/24/2024 04/24/2024
Plot Plan Inspection Passed 4/24/2024 04/24/2024
Occupancy Inspection - Codes Residential Failed 4/24/2024 4/24/2024 04/24/2024
Misc
Corrective Action Required
04/18/2024
-obtain lawn irrigation permit -address to be properly illuminated -outlets in garage to comply with E3901.9 -all non GFCI outlets in unfinished areas to be single receptacle outlets and labeled -afci protection as required by E3902.16 -lockouts for any hard wired appliances breakers. -garage door to be self closing and latching -secondary locking devices on rear slider -window fall guards for primary bedroom windows -uncover all smoke detectors and remove battery pull tab for inspection of smokes (smoke detectors to be interconnected) -handrail to basement to be 34”-38” -address deck post to beam connections not compliant -missing ledgers screw in ledger board. -security screws at rear door
Occupancy Inspection - Codes Residential Failed 4/29/2024 4/29/2024 04/29/2024
Misc
Corrective Action Required
04/24/2024
-obtain lawn irrigation permit -address to be properly illuminated -outlets in garage to comply with E3901.9 (dedicated outlet per vehicle bay) -all non GFCI outlets in unfinished areas to be single receptacle outlets and labeled -afci protection as required by E3902.16 -lockouts for any hard wired appliances breakers. -uncover all smoke detectors and remove battery pull tab for inspection of smokes (smoke detectors to be interconnected)
Occupancy Inspection - Codes Residential Failed 4/30/2024 4/30/2024 04/30/2024
Misc
Corrective Action Required
04/29/2024
-outlets in garage to comply with E3901.9 (dedicated outlet per vehicle bay) -all non GFCI outlets in unfinished areas to be single receptacle outlets and labeled -afci protection as required by E3902.16 -lockouts for any hard wired appliances breakers.
Occupancy Inspection - Codes Residential Full C of O 5/3/2024 5/3/2024 05/03/2024
Misc
Resolved
05/03/2024
-outlets in garage to comply with E3901.9 (dedicated outlet per vehicle bay) -all non GFCI outlets in unfinished areas to be single receptacle outlets and labeled -afci protection as required by E3902.16 -lockouts for any hard wired appliances breakers.
Documents & Images
Date Uploaded File Type Document Name
09/26/2022 License_Tax_Application Lees Summit-signed-signed
09/26/2022 Residental Permit Application_1 Lees Summit - Copy-signed Como
09/26/2022 Approved Plans APPROVED PLANS
09/26/2022 Permit Codes Residential Plan Review
09/27/2022 Plot Plan approved plot plan
09/27/2022 Permit Codes Residential Plan Review
10/04/2022 M L Crose 2122 SW Red Barn Ln LSMO Retreat @ Hook Farms Lot 58 Footing Inspection Report 10-4-22
10/12/2022 Permit DS Building Permit
10/12/2022 Receipt Receipt for transaction: 2022-008222
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
12/01/2022 Final_2022_11_03_DPier_LSMO_Pat Cochran Concrete
12/07/2022 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
04/05/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
07/26/2023 Overgrown vegetation 1
08/25/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
01/16/2024 Letter INSPECTION SUMMARY
01/16/2024 Letter INSPECTION SUMMARY
01/16/2024 Letter Codes 140 Day Letter
02/06/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
05/03/2024 Letter Codes Final Certificate of Occupancy
05/03/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home