Permit Application Status

PRRES20224220


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224220
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
08/30/2022
09/01/2022
02/27/2023
09/15/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CBRUNING@NEWMARKHOMESKC.COM  
Not shown for privacy reasons.
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,968.37 $1,968.37 Paid 09/01/2022
Right of Way Permit Fee $85.00 $85.00 Paid 09/01/2022
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/01/2022
Water Tap Fee $3,730.00 $3,730.00 Paid 09/01/2022
Water Meter Fee $550.50 $550.50 Paid 09/01/2022
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 09/01/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/21/2022 (10:30) 9/21/2022 09/21/2022
Misc
Informational
09/21/2022
UFER location West wall 3’ back from front
Underslab Plumbing Inspection - Residential Failed 10/12/2022 10/12/2022 10/12/2022
Miscellaneous Correction
Corrective Action Required
10/12/2022
- REMOVE STANDING WATER
Underslab Plumbing Inspection - Residential Passed 10/13/2022 10/13/2022 10/13/2022
Miscellaneous Correction
Resolved
10/13/2022
- REMOVE STANDING WATER
Piers/Caissons Inspection - Residential Passed 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
3RD PARTY BY BOB ROWE @ VAN DEURZEN (2) 24" X 48" DECK PIERS APPROVED
Sewer Service Inspection - R Passed 3/24/2023 (2:00) 3/24/2023 03/24/2023
Water Service Inspection - R Passed 3/30/2023 (1:45) 3/30/2023 03/30/2023
Gas Service Inspection - Residential Failed 4/10/2023 4/10/2023 04/10/2023
Miscellaneous Correction
Corrective Action Required
04/10/2023
- no presure on gauge
Electrical Service Inspection Passed 4/10/2023 4/10/2023 04/10/2023
All Rough Inspection - Residential Failed 4/10/2023 4/10/2023 04/10/2023
Miscellaneous Correction
Corrective Action Required
04/10/2023
- Nail exterior siding to sill plate to code throughout - deck cover closed and cannot be inspected - Tighten anchor bolts garage - Minimum of 3 studs on exterior corner garage/entry short return wall - Strap top plate garage at entry for short overlap - Stud spacing at single bay garage - Nail off exterior corner double bay garage - Solid block sheeting breaks in garage, low in single bay and under header of double bay - Repair penetrations in floor at laundry - Fb floor in bathroom by laundry - Repair floor at closet near laundry - Address no overlap of top plate exterior corner of bathroom 2 - Complete CSPF nail pattern and strap in bedroom 2 - Fb east side top plate at breakfast room - Plans call for (3) 2x10” header over windows in great room - Nail exterior corner to code great room near fireplace - Fire block soffit above fireplace - Nail exterior corner owner suite - Anchor all steel columns in basement - Support soffits wider than 4’ in basement - Solid block cantilever in basement - Solid block joist under island per plan - Provide joist hanger bedroom 5 - Fb beam pockets bedroom 4 - Fb beam pocket bedroom 3 - Missing joist hanger mechanical room
All Rough Inspection - Residential Failed 4/20/2023 4/20/2023 04/20/2023
Miscellaneous Correction
Corrective Action Required
04/10/2023
- Nail exterior siding to sill plate to code throughout - Address no overlap of top plate exterior corner of MASTER BEDROOM - Solid block cantilever in basement ( MECHANICAL ROOM)
Gas Service Inspection - Residential Passed 4/20/2023 4/20/2023 04/20/2023
Miscellaneous Correction
Resolved
04/20/2023
All Rough Inspection - Residential Passed 4/21/2023 4/21/2023 04/21/2023
Miscellaneous Correction
Resolved
04/21/2023
Driveway Inspection Partial 5/22/2023 5/22/2023 05/22/2023
Misc
Informational
05/22/2023
5-22-23 DP. Contractor had DW formed, aggregate compacted, no sidewalk on plot plan. Approved to pour.
Occupancy Inspection - Codes Residential Failed 8/1/2023 8/1/2023 08/01/2023
Misc
Corrective Action Required
08/01/2023
-No posted address -Clean up mud in the street
Occupancy Inspection - Codes Residential Failed 8/2/2023 8/2/2023 08/02/2023
Misc
Corrective Action Required
08/01/2023
-Provide erosion control methods or sod before further inspections, clean mud from street -Missing cover plates at front bedroom -Provide code compliant step at back door -Whirlpool pump motor requires min. 12x12 access unless otherwise required per manufacturer -Countertop surfaces by fireplace require work surface receptacles -Kitchen counter receptacles are required within 2' of range
Erosion Control Inspection Residential Failed 8/2/2023 08/02/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/02/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 8/2/2023 08/02/2023
Misc
Corrective Action Required
08/02/2023
-Provide erosion control methods or sod before further inspections, clean mud from street -Final grade and sod -Missing cover plates at front bedroom -Provide code compliant step at back door -Whirlpool pump motor requires min. 12x12 access unless otherwise required per manufacturer -Countertop surfaces by fireplace require work surface receptacles -Kitchen counter receptacles are required within 2' of range -Obtain irrigation permit and backflow report -Driveway inspection pending
Occupancy Inspection - Codes Residential Ready for Temp CO 8/3/2023 8/3/2023 08/03/2023
Misc
Corrective Action Required
08/02/2023
-Final grade and sod -Obtain irrigation permit and backflow report -Driveway inspection pending
Erosion Control Inspection Residential Partial 08/03/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/03/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
08/03/2023
8/3/23 Erosion control in compliance at time of inspection
Driveway Inspection Passed 8/3/2023 8/3/2023 08/03/2023
Misc
Informational
05/22/2023
5-22-23 DP. Contractor had DW formed, aggregate compacted, no sidewalk on plot plan. Approved to pour. 8-3-23 DP. DW was poured, forms have been removed. Passed.
Occupancy Inspection - Codes Residential Failed 9/8/2023 9/8/2023 09/08/2023
Misc
Partial Correction
09/08/2023
-Obtain irrigation permit and backflow report
Occupancy Inspection - Codes Residential Full C of O 9/15/2023 9/15/2023 09/15/2023
Misc
Resolved
09/15/2023
Documents & Images
Date Uploaded File Type Document Name
08/30/2022 2022_08_26_22-344 Lot 183 Woodside Ridge_Permit Drawings
08/30/2022 Lees Summit Builidng Permit Application Signed
08/31/2022 Permit Codes Residential Plan Review
08/31/2022 Plot Plan Approved Plot Plan
09/01/2022 Approved Plans Approved Drawings
09/01/2022 Permit Codes Residential Plan Review
09/01/2022 Permit DS Building Permit
09/01/2022 Receipt Receipt for transaction:2022-007202
09/21/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/18/2022 2055 NW O'Brien Rd_DECK PIER INSP_2022-10-17
10/19/2022 Letter INSPECTION SUMMARY
01/10/2023 Final_2023_01_09_PortFrm_LSMO_New Mark Homes
02/21/2023 2023_02_21_22-344 Whispering Woods Lot 38_Great Room window headers(1)
03/24/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
08/01/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/03/2023 Receipt Receipt for transaction:2023-005996
08/03/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter Field Certificate of Occupancy
09/15/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home