Permit Application Status

PRRES20223033


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223033
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 01/12/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 01/12/2023 12:00 AM by username 'Mark Harding'.
07/01/2022
07/21/2022
01/15/2023
09/28/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR STE 100  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 07/21/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/21/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/21/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 07/21/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 07/21/2022
9110078-Valuation Fee New Single Family $1,502.26 $1,502.26 Paid 07/21/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/17/2022 08/17/2022
Sewer Service Inspection - R Passed 8/17/2022 (9:15) 8/17/2022 08/17/2022
Water Service Inspection - R Passed 8/18/2022 (10:30) 8/18/2022 08/18/2022
Underslab Plumbing Inspection - Residential Not Ready 8/25/2022 8/25/2022 08/25/2022
Misc
Corrective Action Required
08/25/2022
inspection denied no erosion control incorrect address posted. Mitchell Schwarz 08/25/2022 11:12 AM
Underslab Plumbing Inspection - Residential Failed - Stop Work 1/12/2023 01/12/2023
Misc
Corrective Action Required
08/25/2022
inspection denied no erosion control incorrect address posted. Mitchell Schwarz 08/25/2022 11:12 AM
Misc
Corrective Action Required
01/12/2023
underslab plumbing installed without inspection. Mitchell Schwarz 01/12/2023 10:32 AM
Underslab Plumbing Inspection - Residential Passed 1/12/2023 01/12/2023
Misc
Resolved
01/12/2023
inspection denied no erosion control incorrect address posted. Mitchell Schwarz 08/25/2022 11:12 AM
Misc
Informational
01/12/2023
email was provided by Tri county plumbing and the issue has been resolved.
Electrical Service Inspection Failed 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/06/2023
Identify ufer ground at breaker panel
Gas Service Inspection - Residential Failed 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/06/2023
Complete gas line install at fire places Repair and protect csst in basement as stated on all rough inspection
All Rough Inspection - Residential Failed 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/06/2023
-All anchor bolts in garage to be tight -Complete gas line install at fire places or provide shut offs -seal penetrations and pan in R/a joist space above bed 4 and hall -seal bed 4 wall into basement bath furr down -pann above furr down in basement bath for R/a joist space (seal penetrations as well) -address csst in basement at bottom of stairs. Damaged insulation. Protect from bottom of floor joist and it’s approved protection plate -identify ufer ground at panel -address return air panning above wet bar area furr down -un cover covered patio for inspection of framing and gas line
Electrical Service Inspection Passed 2/21/2023 2/21/2023 02/21/2023
Misc
Resolved
02/21/2023
Identify ufer ground at breaker panel
All Rough Inspection - Residential Passed 2/21/2023 2/21/2023 02/21/2023
Misc
Resolved
02/21/2023
-All anchor bolts in garage to be tight -Complete gas line install at fire places or provide shut offs -seal penetrations and pan in R/a joist space above bed 4 and hall -seal bed 4 wall into basement bath furr down -pann above furr down in basement bath for R/a joist space (seal penetrations as well) -address csst in basement at bottom of stairs. Damaged insulation. Protect from bottom of floor joist and it’s approved protection plate -identify ufer ground at panel -address return air panning above wet bar area furr down -un cover covered patio for inspection of framing and gas line
Gas Service Inspection - Residential Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/06/2023
Provide shut off for gas line at exterior csst gas line
Gas Service Inspection - Residential Passed 2/23/2023 2/23/2023 02/23/2023
Misc
Resolved
02/23/2023
Provide shut off for gas line at exterior csst gas line
Driveway Inspection Partial 3/29/2023 3/29/2023 03/29/2023
Misc
Corrective Action Required
03/29/2023
3-29-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 4/5/2023 4/5/2023 04/05/2023
Misc
Corrective Action Required
03/29/2023
3-29-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 4-5-23 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Failed 4/28/2023 04/28/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 8/11/2023 08/11/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation around lot
Erosion Control Inspection Residential Passed 8/16/2023 8/16/2023 08/16/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/16/2023
Piers/Caissons Inspection - Residential Passed 09/26/2023
Occupancy Inspection - Codes Residential Failed 9/26/2023 9/26/2023 09/26/2023
Misc
Corrective Action Required
09/26/2023
Identify sewer tracer wire.
Plot Plan Inspection Passed 09/28/2023
Occupancy Inspection - Codes Residential Full C of O 9/28/2023 9/28/2023 09/28/2023
Misc
Resolved
09/28/2023
Identify sewer tracer wire.
Documents & Images
Date Uploaded File Type Document Name
07/19/2022 Approved Plans APPROVED PLANS
07/19/2022 Permit Codes Residential Plan Review
07/20/2022 Application Form PAGE ONE OF APPLICATION
07/20/2022 Application Form application
07/20/2022 Permit Codes Residential Plan Review
07/20/2022 Plot Plan approved plot plan
07/21/2022 Permit DS Building Permit
07/21/2022 Receipt Receipt for transaction:2022-005956
08/04/2022 2107 SW Red Barn Lane LSMO Retreat @ Hook Farms Lot 79 Footing Inspection 8-3-22
08/18/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
10/20/2022 Final_2022_09_28_SuspStoop DPier_LSMO_Pat Cochran Concrete
12/07/2022 2107 SW Red Barn ROW
12/07/2022 Receipt Receipt for transaction:2022-009349
01/12/2023 Letter Codes 140 Day Letter
01/12/2023 Letter Stop Work Order
01/12/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter Stop Work Order
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
03/29/2023 Letter INSPECTION SUMMARY
04/05/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter Field Certificate of Occupancy
09/28/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home