Permit Application Status

PRRES20222877


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222877
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
06/23/2022
07/12/2022
12/21/2022
11/13/2023
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Erin Skinner, Address:1314 SW Market Street  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,566.15 $1,566.15 Paid 07/12/2022
Right of Way Permit Fee $85.00 $85.00 Paid 07/12/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/12/2022
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/12/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 07/12/2022
Water Meter Fee $479.24 $479.24 Paid 07/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/16/2022 8/16/2022 08/16/2022
Misc
Informational
08/16/2022
FOOTING APPROVED BY DAVID AINSWORTH ON 8/12/22
Underground Electrical Inspection - Residential Passed 9/7/2022 09/07/2022
Underslab Plumbing Inspection - Residential Passed 9/7/2022 9/7/2022 09/07/2022
Sewer Service Inspection - R Passed 9/23/2022 9/23/2022 09/23/2022
Water Service Inspection - R Passed 9/27/2022 (1:00) 9/27/2022 09/27/2022
Piers/Caissons Inspection - Residential Passed 10/26/2022 10/26/2022
Misc
Informational
10/26/2022
3RD PARTY DECK PIERS BY TODD LANGENHORST @ VAN DEURZEN UPLOADED TO PERMIT
Miscellaneous Inspection Passed 4/5/2023 04/05/2023
Misc
Informational
04/05/2023
permit being extended per Mark Harding
Electrical Service Inspection Passed 5/19/2023 5/19/2023 05/19/2023
Gas Service Inspection - Residential Passed 5/19/2023 5/19/2023 05/19/2023
All Rough Inspection - Residential Failed 5/19/2023 5/19/2023 05/19/2023
Misc
Corrective Action Required
05/19/2023
-MAINTAIN EROSION CONTROL -check nail pattern on exterior corners and add where needed -address rafters landing on blocks throughout garage -address CSPF not extending to corner in living room area -hangers missing nails at I-beam in kitchen living room area -address CSPF connection to sill plate in dining room -bedroom 2 missing 2x4 exterior corner, provide minimum 3 studs per corner, left side of closet and north west corner -address rafters landing on blocks throughout upstairs -protect wiring within 6th of attic access -address over bored studs at master bedroom and bathroom -strap top plate at same location -missing one nail in hanger at east side of basement -anchor bolt missing near west basement egress window
All Rough Inspection - Residential Failed 6/2/2023 6/2/2023 06/02/2023
Misc
Corrective Action Required
05/19/2023
MAINTAIN EROSION CONTROL-Restore silt fence at perimeter and maintain gravel filter with min 6" lift of 3/4" gravel. Address erosion control before rescheduling -address rafters landing on blocks throughout garage -address rafters landing on blocks throughout upstairs -strap top plate at same location-Strap top plates lapped less than 24" at master bed wall/ master bath intersecting wall location and at master bath/ master closet location (marked on the walls)
Erosion Control Inspection Residential Failed 06/02/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/02/2023
6/2/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN EROSION CONTROL-Restore silt fence at perimeter and maintain gravel filter with min 6" lift of 3/4" gravel. Address erosion control before rescheduling
All Rough Inspection - Residential Passed 6/8/2023 6/8/2023 06/08/2023
Misc
Resolved
06/08/2023
MAINTAIN EROSION CONTROL-Restore silt fence at perimeter and maintain gravel filter with min 6" lift of 3/4" gravel. Address erosion control before rescheduling -address rafters landing on blocks throughout garage -address rafters landing on blocks throughout upstairs -strap top plate at same location-Strap top plates lapped less than 24" at master bed wall/ master bath intersecting wall location and at master bath/ master closet location (marked on the walls)
Driveway Inspection Partial 7/19/2023 7/19/2023 07/20/2023
Misc
Informational
07/20/2023
7-19-23 DP Crew had DW Formed, aggregate compacted. Approved to pour.
Sidewalk Inspection Partial 7/19/2023 7/19/2023 07/20/2023
Misc
Informational
07/20/2023
7-19-23 DP. SW was formed, aggregate compacted. Cross slopes were a little wishy washy. Contractor went through with me and got the slopes in compliance. But conditions can change. Approved to pour.
Sidewalk Inspection Partial 08/03/2023
Misc
Informational
07/20/2023
7-19-23 DP. SW was formed, aggregate compacted. Cross slopes were a little wishy washy. Contractor went through with me and got the slopes in compliance. But conditions can change. Approved to pour. 8-3-23 DP. SW on side of house not connected to existing SW. Can't pass until finished.
Driveway Inspection Passed 8/3/2023 8/3/2023 08/03/2023
Misc
Informational
07/20/2023
7-19-23 DP Crew had DW Formed, aggregate compacted. Approved to pour. 8-3-23 DP DW was poured, forms have been removed, cross slopes are in compliance. Passed.
Sidewalk Inspection Partial 9/5/2023 9/5/2023 09/05/2023
Misc
Informational
08/03/2023
7-19-23 DP. SW was formed, aggregate compacted. Cross slopes were a little wishy washy. Contractor went through with me and got the slopes in compliance. But conditions can change. Approved to pour. 8-3-23 DP. SW on side of house not connected to existing SW. Can't pass until finished. 9-5-23 A.A Rest of sidewalk on north side of lot is formed. Aggregate is compacted. Slope is in compliance but conditions may change. Approved to pour.
Sidewalk Inspection Passed 9/19/2023 9/19/2023 09/14/2023
Misc
Informational
09/12/2023
7-19-23 DP. SW was formed, aggregate compacted. Cross slopes were a little wishy washy. Contractor went through with me and got the slopes in compliance. But conditions can change. Approved to pour. 8-3-23 DP. SW on side of house not connected to existing SW. Can't pass until finished. 9-5-23 A.A Rest of sidewalk on north side of lot is formed. Aggregate is compacted. Slope is in compliance but conditions may change. Approved to pour. 9-12-23 A.A SW is poured. Slopes are in compliance. 2 panels marked that are cracked and need to be replaced, Will recheck slopes on new panels after repair. Forms are still on. 9-14-23 A.A .The 2 panels that were cracked have been replaced. Slopes are in compliance. Forms are pulled. Passed
Sidewalk Inspection Passed 9/12/2023 9/12/2023 09/14/2023
Misc
Informational
09/05/2023
7-19-23 DP. SW was formed, aggregate compacted. Cross slopes were a little wishy washy. Contractor went through with me and got the slopes in compliance. But conditions can change. Approved to pour. 8-3-23 DP. SW on side of house not connected to existing SW. Can't pass until finished. 9-5-23 A.A Rest of sidewalk on north side of lot is formed. Aggregate is compacted. Slope is in compliance but conditions may change. Approved to pour. 9-12-23 A.A SW is poured. Slopes are in compliance. 2 panels marked that are cracked and need to be replaced, Will recheck slopes on new panels after repair. Forms are still on.
Erosion Control Inspection Residential Partial 11/10/2023 11/10/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/10/2023
6/2/23 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN EROSION CONTROL-Restore silt fence at perimeter and maintain gravel filter with min 6" lift of 3/4" gravel. Address erosion control before rescheduling
Plot Plan Inspection Passed 11/10/2023 11/10/2023
Erosion Control Inspection Residential Passed 11/10/2023 11/10/2023
Occupancy Inspection - Codes Residential Failed 11/10/2023 11/10/2023 11/10/2023
Misc
Informational
05/19/2023
Water hammer devises are in the wall
Misc
Corrective Action Required
11/10/2023
- Pay all fees - Lower water valve to gade - Door at garage entry must be self closing and latch.
Occupancy Inspection - Codes Residential Full C of O 11/13/2023 11/13/2023 11/13/2023
Misc
Resolved
11/13/2023
Water hammer devises are in the wall
Misc
Resolved
11/13/2023
- Lower water valve to gade - Door at garage entry must be self closing and latch.
Documents & Images
Date Uploaded File Type Document Name
06/23/2022 WR 172 - Permit application
06/23/2022 WR 172 Tax application
06/24/2022 Permit Codes Residential Plan Review
06/30/2022 Plot Plan Approved Plot Plan
07/05/2022 Approved Plans APPROVED PLANS
07/05/2022 Permit Codes Residential Plan Review
07/12/2022 Permit DS Building Permit
07/12/2022 Receipt Receipt for transaction:2022-005672
08/15/2022 Wilmoth 2105 NW Obrien Rd LSMO Foundation Subgrade and Footing Inspection Reporft 8-12-22
08/16/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
10/11/2022 2105 NW O'Brien St_DECK PIER INSP_2022-10-10
10/26/2022 Letter INSPECTION SUMMARY
04/04/2023 WR 172 TJI
04/18/2023 WR 172 - 2105 NW OBRIEN RD_I JST LAYOUT_4-18-23
04/18/2023 Approved Plans APPROVED FLOOR JOIST LAYOUT
05/19/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/07/2023 2105 NW O'Brien_Framing Evaluation Report_6-7-23
06/08/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
09/05/2023 Letter INSPECTION SUMMARY
09/12/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/13/2023 Letter Codes Final Certificate of Occupancy
11/13/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home