Permit Application Status

PRRES20222875


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222875
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ROOF TRUSSES.
06/23/2022
06/28/2022
12/24/2022
04/03/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
michael@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/28/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/28/2022
Water Meter Fee $479.24 $479.24 Paid 06/28/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/28/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/28/2022
Valuation Fee New Single Family $1,665.47 $1,665.47 Paid 06/28/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 01/19/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 01/25/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 02/16/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/14/2022 (11:15) 7/14/2022 07/14/2022
Sewer Service Inspection - R Passed 7/14/2022 7/14/2022 07/14/2022
Water Service Inspection - R Passed 7/15/2022 (1:00) 7/15/2022 07/15/2022
Underslab Plumbing Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Electrical Service Inspection Passed 10/4/2022 10/4/2022 10/04/2022
Gas Service Inspection - Residential Failed 10/4/2022 10/4/2022 10/04/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
PROVIDE MIN 10 PSI FOR 15 MIN
Piers/Caissons Inspection - Residential Passed 10/4/2022 10/04/2022
Misc
Informational
10/04/2022
FOOTING INLO DECK PIERS
All Rough Inspection - Residential Failed 10/4/2022 10/4/2022 10/04/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
Provide anchor bolt end of plate at SCH 40 column garage Provide anchor bolt within 12" Of plate break rear basement wall Provide anchor bolt end of plate at missing patio door Provide electrical protection plate under patio window Provide boca plate DWV bonus room corner basement Replace studs / top plate at wet bar / furnace Provide boca plates at above Tighten anchor bolts basement Seal gaps in fire blocking basement bedroom closet Vent exhaust fan to day light basement bathroom Provide anchor bolt within 12" of plate break Basement bedroom Seal upward penetration bed 1 door Fire block tub trap bed 1 Provide 4 stud pack at girder truss bearing point laundry room Provide stud shoe laundry DWV bearing wall Nail hanger at HVAC owners entry Provide 4 stud pack at girder truss bearing point at stairs & throughout Provide CS-PF exterior wall bracing dining room per plan Strap corners dining room / great room no plate overlap wall heights differ Double wall construction dining & great room per plan Seal fire blocking double wall at stairway Provide (6) 2x6 GT bearing at loft per plan Replace stud bed 2 Land conductors in a box bed 2 Solid block & nail exterior wall sheathing top plate bed 3 closet & bath 2 Replace sides bath 2 & bed 3 Tie exterior corners bed 3 wall heights differ Land conductors in a box bed 3 Address truss bearing bed 4 at HVAC chase Missing hanger bed 3 above vanity door Provide (2) 2x4 vertical to support ridge deck Missing LIB near SCH 40 column garage Nail top plate to header 3" O.C. Garage portal Address notched joist rear corner garage at DWV Address 6x6 deck post not continuous per plan Nail exterior wall sheathing per code
Footing Inspection - Residential Passed 10/13/2022 10/13/2022
Informational
10/13/2022
3RD PARTY FOOTING BY LUCAS CARLSON @ EVERSTEAD UFER LOCATED IN TOP L CORNER OF GARAGE WALL
All Rough Inspection - Residential Not Ready 10/14/2022 10/14/2022 10/14/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
Provide CS-PF exterior wall bracing great room per plan Seal fire blocking 2nd story dbl wall at stairway ( trusses) Provide (6) 2x6 GT bearing at loft per plan Address notched joist rear corner garage at DWV Address 6x6 deck post not continuous per plan Nail exterior wall sheathing per code GAS SERVICE FAILED NO PRESSURE
Gas Service Inspection - Residential Passed 10/18/2022 10/18/2022 10/18/2022
Miscellaneous Correction
Resolved
10/18/2022
All Rough Inspection - Residential Failed 10/18/2022 10/18/2022 10/18/2022
Miscellaneous Correction
Corrective Action Required
10/14/2022
Address notched joist rear corner garage at DWV Address 6x6 deck post not continuous per plan { not installed to engineers letter on 10/18/22)
All Rough Inspection - Residential Failed 10/19/2022 10/19/2022 10/19/2022
Miscellaneous Correction
Corrective Action Required
10/18/2022
Address 6x6 deck post not continuous per plan { not installed to engineers letter on 10/18/22) 10/19/22 - ENGINEER LETTER STATES FOR 24" CS-16 STRAP CENTERED AT SPLICE FOR NON CONTINUOUS POST REPAIR
Driveway Inspection Partial 10/25/2022 10/25/2022 10/26/2022
Misc
Informational
10/26/2022
Driveway was dug out to get below soaked ground level. Had aggregate placed and compacted. 10/25/22 ES
Sidewalk Inspection Partial 10/25/2022 10/25/2022 10/26/2022
Misc
Informational
10/26/2022
Sidewalk was dug out to get below soaked ground level. Had aggregate placed and compacted. 10/25/22 ES
Driveway Inspection Passed 11/4/2022 11/4/2022 12/01/2022
Misc
Informational
10/26/2022
Driveway was dug out to get below soaked ground level. Had aggregate placed and compacted. 10/25/22 ES 12-1-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Passed 11/4/2022 11/4/2022 12/01/2022
Misc
Informational
10/26/2022
Sidewalk was dug out to get below soaked ground level. Had aggregate placed and compacted. 10/25/22 ES 12-1-22 AN sidewalk looks good and meets Ada spec
Occupancy Inspection - Codes Residential Failed 1/19/2023 1/19/2023 01/19/2023
Misc
Corrective Action Required
01/19/2023
- Address 6x6 deck post not continuous per plan { not installed to engineers letter on 10/18/22) 10/19/22 - ENGINEER LETTER STATES FOR 24" CS-16 STRAP CENTERED AT SPLICE FOR NON CONTINUOUS POST REPAIR - Final grading and sod - Provide splash blocks - Seal gaps at attic access in garage - Steps at garage entry over allowed variance of 3/8'
Plot Plan Inspection Passed 1/23/2023 01/23/2023
All Rough Inspection - Residential Passed 1/25/2023 1/25/2023 01/25/2023
Miscellaneous Correction
Resolved
01/25/2023
Address 6x6 deck post not continuous per plan { not installed to engineers letter on 10/18/22) 10/19/22 - ENGINEER LETTER STATES FOR 24" CS-16 STRAP CENTERED AT SPLICE FOR NON CONTINUOUS POST REPAIR
Occupancy Inspection - Codes Residential Ready for Temp CO 1/25/2023 1/25/2023 01/25/2023
Misc
Corrective Action Required
01/19/2023
- Final grading and sod - Provide splash blocks
Occupancy Inspection - Codes Residential Ready for Temp CO 02/14/2023
Misc
Corrective Action Required
01/25/2023
- Final grading and sod - Provide splash blocks
Occupancy Inspection - Codes Residential Failed 3/7/2023 3/7/2023 03/07/2023
Misc
Corrective Action Required
02/14/2023
- Provide splash blocks-Foundation drainage to extend 36' from foundation
Erosion Control Inspection Residential Passed 3/7/2023 3/7/2023 03/07/2023
Occupancy Inspection - Codes Residential Failed 3/9/2023 3/9/2023 03/09/2023
Misc
Corrective Action Required
03/07/2023
- splash blocks-Foundation drainage need to extend 36' from foundation, existing ones are too short -address grounding rod protruding from sod near electrical service entrance
Occupancy Inspection - Codes Residential Full C of O 4/3/2023 4/3/2023 04/03/2023
Misc
Resolved
04/03/2023
Documents & Images
Date Uploaded File Type Document Name
06/24/2022 Approved Plans APPROVED PLOT PLAN
06/24/2022 Permit Codes Residential Plan Review
06/27/2022 Permit Codes Residential Plan Review
06/27/2022 W0 #156 - Permit App
06/28/2022 Approved Plans APPROVED TRUSS PACKAGE
06/28/2022 Approved Plans APPROVED TRUSS LAYOUT
06/28/2022 Approved Plans APPROVED PLANS
06/28/2022 Permit Codes Residential Plan Review
06/28/2022 Permit DS Building Permit
06/28/2022 Receipt Receipt for transaction:2022-005218
07/05/2022 156 Woodside Ridge FTNG
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/12/2022 156 Woodside Ridge Letter 1
10/12/2022 156 Woodside Ridge FTNG
10/13/2022 Letter INSPECTION SUMMARY
10/14/2022 B0E2AF7A-ADE9-4911-B19D-D9391D9F360A
10/14/2022 Letter INSPECTION SUMMARY
10/17/2022 156 Woodside Ridge non continuous post letter
10/17/2022 156 Woodside Ridge non continuous post letter-revised
10/18/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
10/18/2022 156screwpatterntjoist
10/19/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
01/19/2023 Receipt Receipt for transaction:2023-000333
01/19/2023 Letter INSPECTION SUMMARY
01/19/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
01/24/2023 156 Woodside Ridge non continuous post letter 1-23-23- signed
01/25/2023 Letter INSPECTION SUMMARY
01/25/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/25/2023 Receipt Receipt for transaction:2023-000487
02/14/2023 WO #156 - TCO Extension Request
02/14/2023 Letter INSPECTION SUMMARY
02/16/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/16/2023 Receipt Receipt for transaction:2023-000896
03/06/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
03/07/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/09/2023 Letter INSPECTION SUMMARY
04/03/2023 Letter Codes Final Certificate of Occupancy
04/03/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home