Summary
PRRES20222754
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINSIHED BASEMENT - COVERED DECK
06/20/2022
06/27/2022
12/18/2022
03/10/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/27/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/27/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/27/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/27/2022
Water Meter Fee $479.24 $479.24 Paid 06/27/2022
Valuation Fee New Single Family $1,383.85 $1,383.85 Paid 06/27/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 02/13/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 02/22/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/8/2022 07/08/2022
Sewer Service Inspection - R Passed 7/26/2022 (11:30) 7/26/2022 07/26/2022
Water Service Inspection - R Passed 7/26/2022 (1:15) 7/26/2022 07/26/2022
Underslab Plumbing Inspection - Residential Passed 8/11/2022 8/11/2022 08/11/2022
Gas Service Inspection - Residential Passed 11/1/2022 11/1/2022 11/01/2022
Electrical Service Inspection Passed 11/1/2022 11/1/2022 11/01/2022
Erosion Control Inspection Residential Failed 11/1/2022 11/01/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/01/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 11/1/2022 11/1/2022 11/01/2022
Miscellaneous Correction
Corrective Action Required
11/01/2022
No deck pier inspection on record Covered deck shall have 1 roof vent & 4 soffit vents per plan Secure deck fire place Secure gas line deck fireplace Seal fire blocking deck fireplace Missing hanger master bed Missing truss screw / H2.5 each side fire place Missing truss screws / H2.5s foyer Missing hangers & truss screws / H2.5s front porch Seal upward penetrations front door Solid block sheathing break garage at GFCI Seal upward penetration above GFCI Seal b vent chase garage / master closet Fire blocking above refrigerator Seal fire blocking dead space at oven Solid block sheathing break under window office Solid block nail sheathing corner ft porch / office Provide CS-PF exterior bracing at foyer per plan Seal upward penetration right of fireplace Provide CS-PF window left of fireplace Snow blocking above deck windows Complete CS-PF nailing deck door Fire stop tub trap Provide anchor bolts SCH 40 columns Tighten anchor bolt bed 4 closet Provide electrical nail guard at bed 3 vanity Provide joist hangers unfinished area near gas line entry point Provide flashing above horizontal window trim
All Rough Inspection - Residential Failed 11/4/2022 11/4/2022 11/04/2022
Miscellaneous Correction
Corrective Action Required
11/01/2022
No deck pier inspection on record Covered deck shall have 1 roof vent & 4 soffit vents per plan Seal fire blocking deck fireplace (covered) Provide CS-PF exterior bracing at foyer per plan Provide CS-PF window left of fireplace Provide electrical nail guard at bed 3 vanity Provide flashing above horizontal window trim
All Rough Inspection - Residential Not Ready 11/10/2022 11/10/2022 11/10/2022
Miscellaneous Correction
Corrective Action Required
11/04/2022
No deck pier inspection on covered deck CS-PF per IRC R602.10 Provide CS-PF exterior bracing at foyer per plan ( header to jack stud straps per table R602.10.6.4 NOT DONE) Provide CS-PF window left of fireplace ( provide straps ) NOT DONE Provide CS-PF nailing 3 windows great room NOT DONE Provide electrical nail guard at bed 3 vanity Basement ( NOT DONE 10/11/22) Marked with red ink pen again
All Rough Inspection - Residential Failed 11/14/2022 11/14/2022 11/14/2022
Miscellaneous Correction
Corrective Action Required
11/10/2022
No deck pier inspection on covered deck Okay to insulate
Sidewalk Inspection Partial 11/21/2022 11/21/2022 11/21/2022
Misc
Informational
11/21/2022
Sidewalk was framed up with aggregate in and compacted. 11/21/22 ES
Driveway Inspection Partial 11/21/2022 11/21/2022 11/21/2022
Misc
Informational
11/21/2022
Driveway was framed up with aggregate in and compacted. 11/21/22 ES
Driveway Inspection Passed 11/28/2022 11/28/2022 11/28/2022
Misc
Informational
11/21/2022
Driveway was framed up with aggregate in and compacted. 11/21/22 ES 11-28-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Passed 11/28/2022 11/28/2022 11/28/2022
Misc
Informational
11/21/2022
Sidewalk was framed up with aggregate in and compacted. 11/21/22 ES 11-28-22 AN sidewalk looks good and meets Ada spec
All Rough Inspection - Residential Passed 2/14/2023 02/14/2023
Miscellaneous Correction
Corrective Action Required
11/14/2022
Piers/Caissons Inspection - Residential Passed 2/14/2023 02/14/2023
Misc
Informational
02/14/2023
3rd party post pour inspection/testing performed.
Occupancy Inspection - Codes Residential Failed 2/14/2023 2/14/2023 02/14/2023
Misc
Corrective Action Required
02/14/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -GFCI protected outlet for master bath jacuzzi tub -outlet above outdoor fireplace to be secured and spark ring -will check water meter depth and well grade at time of sod. Ensure 14-18” from meter top to well lid.
Plot Plan Inspection Passed 2/14/2023 02/14/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/14/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter depth and well grade at time of sod. Ensure 14-18” from meter top to well lid.
Occupancy Inspection - Codes Residential Full C of O 3/10/2023 3/10/2023 03/10/2023
Misc
Resolved
03/10/2023
Documents & Images
Date Uploaded File Type Document Name
06/20/2022 W0 #197 - Permit App
06/21/2022 Approved Plans APPROVED PLANS
06/21/2022 Approved Plans APPROVED TRUSS LAYOUT
06/21/2022 Approved Plans APPROVED TRUSS PACKAGE
06/21/2022 Permit Codes Residential Plan Review
06/21/2022 Plot Plan APPROVED PLOT PLAN
06/23/2022 Permit Codes Residential Plan Review
06/27/2022 Permit DS Building Permit
06/27/2022 Receipt Receipt for transaction:2022-005150
07/08/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
11/09/2022 fireplacefoam1
11/09/2022 Fireplacfoam2
11/10/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
11/28/2022 Letter INSPECTION SUMMARY
11/28/2022 Letter INSPECTION SUMMARY
11/29/2022 197 Woodside Ridge Post Pour Deck Piers
02/13/2023 Receipt Receipt for transaction:2023-000853
02/14/2023 Letter INSPECTION SUMMARY
02/14/2023 Letter INSPECTION SUMMARY
02/14/2023 Letter INSPECTION SUMMARY
02/14/2023 Letter INSPECTION SUMMARY
02/14/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
02/22/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/22/2023 Receipt Receipt for transaction:2023-001016
03/10/2023 Letter Field Certificate of Occupancy
03/10/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home