Permit Application Status

PRRES20222619


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222619
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED/UNCOVERED DECK STOP WORK ORDER generated on 06/05/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/29/2023 12:00 AM by username 'Shawn Hoffman'.
06/13/2022
07/15/2022
12/11/2022
07/25/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,192.21 $1,192.21 Paid 07/15/2022
Right of Way Permit Fee $85.00 $85.00 Paid 07/15/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/15/2022
8331507-Sewer Connection Fee $630.00 $630.00 Paid 07/15/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 07/15/2022
Water Meter Fee $479.24 $479.24 Paid 07/15/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 07/25/2022
Misc
Informational
07/25/2022
-FOOTING AND PIERS APPROVED BY DAVID AINSWORTH ON 7-20-22
Piers/Caissons Inspection - Residential Passed 07/25/2022
Misc
Informational
07/25/2022
PIERS APPROVED BY DAVID AINSWORTH ON 7-20-22
Underslab Plumbing Inspection - Residential Passed 8/10/2022 8/10/2022 08/10/2022
Sewer Service Inspection - R Passed 8/10/2022 (1:00) 8/10/2022 08/10/2022
Water Service Inspection - R Passed 8/23/2022 (1:00) 8/23/2022 08/23/2022
Gas Service Inspection - Residential Failed 12/16/2022 12/16/2022 12/16/2022
Misc
Corrective Action Required
12/16/2022
provide min 10psi at gas pressure gauge for inspection.
Electrical Service Inspection Passed 12/16/2022 12/16/2022 12/16/2022
All Rough Inspection - Residential Failed 12/16/2022 12/16/2022 12/16/2022
Misc
Corrective Action Required
12/16/2022
-address rafters landing on multiple blocks (provide engineering for fix) -repair broken bath vent above powder room -missing joist hangers above powder room -missing hangers on joists above pantry (resting on non load bearing walls) -missing hangers on joists above prep kitchen(resting on non load bearing wall) -missing joist hangers above laundry(landing on non load bearing walls -missing nails in hangers above master bed -seal top plate penetrations at master bed entry -nail exterior cs-pf -complete plumbing above bed 5 -fire block bed 5 closet walls and dead space into furr down -closet provide support for furr down ceiling joist to floor joists above -fireblock dead space in basement bath to ceiling space -provide minimum 10psi at gas gauge for test -fire block flex room walls into ceiling space -seal penetrations in R/a joist space at bed 4 entry -seal penetrations in 10’ vertical to horizontal fire-blocking(ensure 10’ spacing) -fireblock dead space and walls at joint bath in basement to ceiling space -address over notched floor joist above bed 3 -midway strap all dwv 2” or less in stud bays
All Rough Inspection - Residential Failed 12/29/2022 12/29/2022 12/29/2022
Misc
Corrective Action Required
12/16/2022
-fire block bed 5 closet walls and dead space into furr down -fireblock dead space in basement bath to ceiling space -fire block flex room walls into ceiling space -seal penetrations in R/a joist space at bed 4 entry -seal penetrations in 10’ vertical to horizontal fire-blocking(ensure 10’ spacing) -address over notched stud above bed 3 (provide engineer for fix) Do not insulate
Gas Service Inspection - Residential Passed 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
provide min 10psi at gas pressure gauge for inspection.
All Rough Inspection - Residential Failed 1/3/2023 1/3/2023 01/03/2023
Misc
Corrective Action Required
12/29/2022
-address over notched stud above bed 3 (provide engineer for fix) Okay to insulate
Erosion Control Inspection Residential Failed 03/02/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Sidewalk Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
3-20-23 DP. SW is formed, cross slope is in compliance and aggregate is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete.
Driveway Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
3-20-23 DP. DW is formed, concrete is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete.
Sidewalk Inspection Partial 3/22/2023 3/22/2023 03/22/2023
Misc
Informational
03/20/2023
3-20-23 DP. SW is formed, cross slope is in compliance and aggregate is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete. 3-22-23 DP. When i showed up contractor had concrete on site. There is rain in the forecast later but since subgrade was solid I allowed them to finish pouring. Will need to make sure Surface is good during final.
Driveway Inspection Partial 3/22/2023 3/22/2023 03/22/2023
Misc
Informational
03/20/2023
3-20-23 DP. DW is formed, concrete is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete. 3-22-23 DP. DW is formed, aggregate is compacted, approved to pour
Sidewalk Inspection Passed 4/4/2023 4/4/2023 04/04/2023
Misc
Informational
03/22/2023
3-20-23 DP. SW is formed, cross slope is in compliance and aggregate is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete. 3-22-23 DP. When i showed up contractor had concrete on site. There is rain in the forecast later but since subgrade was solid I allowed them to finish pouring. Will need to make sure Surface is good during final. 4-4-23 DP. SW has been poured, cross slopes are in compliance, forms have been removed. passed
Driveway Inspection Passed 4/4/2023 4/4/2023 04/04/2023
Misc
Informational
03/22/2023
3-20-23 DP. DW is formed, concrete is compacted. Contractor said they weren't pouring today. We have rain in the forecast all day tomorrow so told him to call back in for reinspection after the rain or the day he wants to pour concrete. 3-22-23 DP. DW is formed, aggregate is compacted, approved to pour 4-4-23 DP. DW has been poured, cross slope is in compliance and forms have been removed. Passed.
Plot Plan Inspection Passed 4/12/2023 04/12/2023
Erosion Control Inspection Residential Failed 05/31/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/31/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/31/2023
5/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -NO INSPECTIONS WILL BE PERFROMED UNTIL IN COMPLIANCE
Erosion Control Inspection Residential Failed - Stop Work 6/5/2023 6/5/2023 06/05/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/31/2023
5/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -NO INSPECTIONS WILL BE PERFROMED UNTIL IN COMPLIANCE 6/5/23 -STOP WORK ORDER ISSUED -ESTABLISH EROSION CONTROL METHODS AT PERIMETER OF LOT
Occupancy Inspection - Codes Residential Failed 6/28/2023 6/28/2023 06/28/2023
Misc
Corrective Action Required
06/28/2023
6/28/23 Inspection denied. Address failed all rough corrections
All Rough Inspection - Residential Passed 6/29/2023 06/29/2023
Misc
Resolved
06/29/2023
Erosion Control Inspection Residential Passed 6/29/2023 06/29/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
06/29/2023
5/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -NO INSPECTIONS WILL BE PERFROMED UNTIL IN COMPLIANCE 6/5/23 -STOP WORK ORDER ISSUED -ESTABLISH EROSION CONTROL METHODS AT PERIMETER OF LOT
Occupancy Inspection - Codes Residential Failed 6/29/2023 6/29/2023 06/29/2023
R311.5.3.3 Stair Profile
Corrective Action Required
06/28/2023
- Nosing at deck tairs MEANS OF EGRESS. The radius of curvature at the leading edge of the tread shall be no greater than 9/16 inch (14 mm). A nosing not less than ¾ inch (19 mm) but not more than 1¼ inch (32 mm) shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm) between two stories, including the nosing at the level of floors and landings. Beveling of nosing shall not exceed ½ inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading edge of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted, provided that the opening between treads does not permit the passage of a 4-inch diameter (102 mm) sphere. Exceptions: 1. A nosing is not required where the tread depth is a minimum of 11 inches (279 mm). 2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less. - sidewalk inspection pending - Pay all fees ( irrigation permit) - Missing spindle at inside stairs - Provide graspable handrail for deck - Label non gfci outlet at sump
Occupancy Inspection - Codes Residential Failed 7/11/2023 07/11/2023
R311.5.3.3 Stair Profile
Corrective Action Required
06/29/2023
- Nosing at deck tairs MEANS OF EGRESS. The radius of curvature at the leading edge of the tread shall be no greater than 9/16 inch (14 mm). A nosing not less than ¾ inch (19 mm) but not more than 1¼ inch (32 mm) shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm) between two stories, including the nosing at the level of floors and landings. Beveling of nosing shall not exceed ½ inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading edge of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted, provided that the opening between treads does not permit the passage of a 4-inch diameter (102 mm) sphere. Exceptions: 1. A nosing is not required where the tread depth is a minimum of 11 inches (279 mm). 2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less. - sidewalk inspection pending - Pay all fees ( irrigation permit) - Missing spindle at inside stairs - Provide graspable handrail for deck - Label non gfci outlet at sump
Sidewalk Inspection Passed 7/10/2023 7/10/2023 07/20/2023
Misc
Informational
07/20/2023
Sidewalk passed by Devon Perry on 4/4/23
Occupancy Inspection - Codes Residential Failed 7/20/2023 7/20/2023 07/20/2023
R311.5.3.3 Stair Profile
Resolved
07/20/2023
Misc
Corrective Action Required
07/11/2023
-Handrail at deck to be continuous and uninterrupted per R311.7.8.4
Occupancy Inspection - Codes Residential Full C of O 7/25/2023 7/25/2023 07/25/2023
Misc
Resolved
07/25/2023
-Handrail at deck to be continuous and uninterrupted per R311.7.8.4
Documents & Images
Date Uploaded File Type Document Name
06/13/2022 SKM_C36822061313460
06/13/2022 SKM_C36822061313470
06/14/2022 Approved Plans Approved Drawings
06/14/2022 Permit Codes Residential Plan Review
06/15/2022 Plot Plan Approved Plot Plan
07/08/2022 Permit Codes Residential Plan Review
07/15/2022 Permit DS Building Permit
07/15/2022 Receipt Receipt for transaction:2022-005807
07/21/2022 M L Crose 2221 NW Killarney LN LSMO Woodside Ridge Lot 196 Footing Inspection Report 7-20-22
07/21/2022 Engineer Report/Study ENGINEER REPORT
07/25/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
10/21/2022 2221 NW Kilarney Lane LSMO Woodside Ridge Lot 196 Framing Issue Report 10-20-22
12/08/2022 Approved Plans approved page 2 of plans
12/16/2022 Letter INSPECTION SUMMARY
12/16/2022 Letter INSPECTION SUMMARY
12/16/2022 Letter INSPECTION SUMMARY
12/20/2022 196 Woodside Ridge PF Inspection
12/29/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/11/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
04/12/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter Stop Work Order
06/28/2023 Letter INSPECTION SUMMARY
06/28/2023 Kyle Yancik 2221 NW Killarney Lane LSMO Steel Strappin Report 1-18-23
06/28/2023 Photograph image0 (002)
06/29/2023 Letter INSPECTION SUMMARY
06/29/2023 Letter INSPECTION SUMMARY
06/29/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter Field Certificate of Occupancy
07/25/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home